Electrolux EGG 689 manual Wiring Diagram, Fault Finding, Preliminary Electrical Systems, Check

Page 11

Wiring Diagram

N

1

Brown

L

220 1

240

2

3

0

4

2

A. IGNITOR SWITCH

B. IGNITOR UNIT

Fault Finding

Preliminary Electrical Systems

PLUG (with cover

 

 

 

 

 

 

 

Check

 

 

removed)

 

 

 

 

Earth Wire

(

)

Blue

 

 

Green/Yellow

 

 

Green

START

 

 

 

 

 

 

FUSE

 

Yellow

Isolate appliance

 

 

 

 

and carry out:

 

 

 

 

 

A: Earth Continuity

Neutral Wire

 

 

 

 

check.

Blue

 

 

SOCKET

(face view)

E()

N L

 

 

 

 

 

 

 

 

 

 

 

Blue

 

 

 

 

 

 

 

Brown

 

Green

 

 

 

 

 

 

 

 

 

 

 

Yellow

 

 

 

Carry out:

 

Electricity supply

 

 

 

NO

YES

Carry out:

 

 

 

 

 

 

D: Resistance to

 

 

should now be

 

 

 

 

 

 

C: Polarity check.

 

 

 

 

 

 

 

 

 

 

Earth check.

 

satisfactory.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Has inlet fuse blown?

NO

YES

Inlet wiring

faulty.

Rectify any

fault.

Isolate appliance and carry out:

B:Insulation check. Rectify any fault including replacing fuses as necessary.

A. EARTH CONTINUITY CHECK - Appliance must be electrically disconnected - meter set on W (Ohms) x 1 scale and adjust zero if necessary.

a)Test leads from any appliance earth point to earth

pin on plug. Resistance should be less than 0.1 W (Ohm), check all earth wires for continuity and all contacts are clean and tight.

B. INSULATION CHECK - Appliance electrically disconnected, all switches ON.

a)meter set on W (Ohms) x 1 scale.

Test leads from L to N in appliance terminal block. If meter reads «0» then there is a short circuit.

b)meter set on W (Ohm) x 100 scale.

Repeat test with leads from L to E. If meter reads less than ¥ (infinity) there is a fault.

NOTE - Should it be found that the fuse has failed but no fault is indicated - a detailed continuity check (i.e. by disconnecting and checking each component) is required to trace the faulty component. It is possible that a fault could occur as a result of local burning/arcing but no fault could be found under test. However a detailed visual inspection should reveal evidence of burning around the fault.

11

Image 11
Contents Instruction Booklet Important Safety Information Description of the Hob ContentsOperation Maintenance and CleaningSomething Not Working? Service and Spare PartsSymptom Solution Customer Care Department Guarantee ConditionsAppliance Class Appliance Category II2H3+ Instructions for the InstallerEngineers technical data Supply connectionsLocation Important safety requirementsInstallation When the HOB is First InstalledBuilding over a kitchen unit with door BuildingCut Out Size Building over a cupboard or drawerThis Appliance Must be Earthed Supply cable replacementElectrical connections Permanent ConnectionCheck Wiring DiagramFault Finding Preliminary Electrical SystemsIgnition System / Gas Ignition Commissioning Minimum adjustment screwConversion from Natural Gas to To adjust the gas ratePage Customer Care