Electrolux EGG 689 Instructions for the Installer, Engineers technical data, Supply connections

Page 7

Instructions for the Installer

Engineers technical data

Overall dimensions

Width:

580 mm.

Depth:

510 mm.

Cut out dimensions

Width:

550 mm.

Depth:

470 mm.

Supply connections

Gas:

R 1/2 inch (1/2 inch male) Rear right hand corner

Electric:

230-240V 50Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse.

Ignition HT Spark

 

Spark Generator

Ispra Control's BF 50046

 

230-240V 0.6 YA T 120

Spark Gap

Fixed

Semi-rapid Burner

 

Heat Input

1.9 kW (6483 BTU/HR)

Rapid Burner

Heat Input 2.9 kW Natural Gas (9895 BTU/HR) 2.7 kW L.P.G. (9212 BTU/HR)

Auxiliary Burner

 

Heat Input

1.0 kW (3412 BTU/HR)

TYPE OF GAS

CHARACTERISTICS

 

 

BURNER

RAPID

SEMI-RAPID

AUXILIARY

 

 

 

(large)

(medium)

(small)

 

 

 

 

 

 

 

 

 

 

 

POSITION

MAX

MIN

MAX

MIN

MAX

MIN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

NATURAL GAS

 

VALUE = 37.78 MJ/m

Ws - 50.7 MJ/ m3

 

NOMINAL THERMAL

 

 

 

 

 

 

20 mbar

 

POWER kW

2.9

0.65

1.9

0.45

1.0

0.33

 

NOMINAL FLOW

 

 

 

 

 

 

 

RATE

m3/h

0.276

0.062

0.181

0.043

0.095

0.031

 

NOZZLEREFERENCE

119

Adjust.

96

Adjust.

70

Adjust.

 

 

1/100 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28-30/37 mbar

VALUE = 49.92 MJ/Kg

 

NOMINAL THERMAL

 

 

 

 

 

 

 

 

POWER kW

2.7

0.65

1.9

0.45

1.0

0.33

LPG GAS

 

NOMINAL FLOW

 

 

 

 

 

 

 

RATE

g/h

195

46.8

137

32.4

72

23.8

 

NOZZLEREFERENCE

86

40

71

32

50

28

 

 

1/100 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Burner

Dia. Tap By-pass

 

1/100 mm

Auxiliary

28

Semi-rapid

32

Rapid

40

Aeration adjustment none

APPLIANCE CLASS:

3

APPLIANCE CATEGORY: II2H3+

APPLIANCE GAS SUPPLY: Natural gas G20 / 20mbar

7

Image 7
Contents Instruction Booklet Important Safety Information Description of the Hob ContentsOperation Maintenance and CleaningSymptom Solution Service and Spare PartsSomething Not Working? Customer Care Department Guarantee ConditionsAppliance Class Appliance Category II2H3+ Instructions for the InstallerEngineers technical data Supply connectionsLocation Important safety requirementsInstallation When the HOB is First InstalledBuilding over a kitchen unit with door BuildingCut Out Size Building over a cupboard or drawerThis Appliance Must be Earthed Supply cable replacementElectrical connections Permanent ConnectionCheck Wiring DiagramFault Finding Preliminary Electrical SystemsIgnition System / Gas Ignition Commissioning Minimum adjustment screwConversion from Natural Gas to To adjust the gas ratePage Customer Care