Electrolux CSIG 509 manual Electrical connections, Permanent Connection

Page 21

Electrical connections

Any electrical work required to install this cooker should be carried out by a qualified electrician or competent person, in accordance with the current regulations.

THIS COOKER MUST BE EARTHED.

The manufacturer declines any liability should these safety measures not be observed.

This cooker is designed to be connected to a 230- 240V 50Hz AC electrical supply.

Before switching on, make sure the electricity supply voltage is the same as that indicated on the cooker rating plate. The rating plate is located on the oven frame.

The cooker is supplied with a 3 core flexible supply cord incorporating a 13amp plug fitted. In the event of having to change the fuse, a 13amp ASTA approved (BS 1362) fuse must be used.

Should the plug need to be replaced for any reason, the wires in the mains lead are coloured in accordance with the following code:

Green and Yellow - Earth

Blue- Neutral

Brown- Live

Φ— Connect the green and yellow (earth) wire to the terminal in the plug which is marked with

the letter 'E' or the earth symbol or coloured green and yellow.

Connect the blue (neutral) wire to the terminal in the plug which is marked with the letter 'N' or coloured black.

Connect the brown (live) wire to the terminal in the plug which is marked with the letter 'L' or coloured red.

NOTE: The earth wire should be about 2 cm. longer

than the live and neutral wires.

Upon completion there must be no cut, or stray strands of wire present and the cord clamp must be secure over the outer sheath.

A cut off plug inserted into a 13 amp socket is a serious safety (shock) hazard. Ensure that the cut off plug is disposed of safely.

Permanent Connection

In the case of a permanent connection, it is necessary that you install a double pole switch between the cooker and the electricity supply (mains), with a minimum gap of 3 mm. between the switch contacts and of a type suitable for the required load in compliance with the current electric regulations.

The switch must not break the yellow and green earth cable at any point.

Ensure that the cooker supply cord does not come into contact with surfaces with temperatures higher than 50 deg. C.

1

FO 0390

21

Image 21
Contents Csig Important Safety Information Description of the Cooker ContentsAccessories Control PanelOven Cavity Using the Hob Hob burnersTriple-crown burner Gas oven and Electric grill Before the First Use of the CookerCondensation and steam Hints and TipsCookware Effects of dishes on cooking resultsMeat & Poultry Gas Oven Cooking ChartsYorkshire Pudding Baked VegetablesPuddings CakesYeast Mixtures How to Use the Grill GrillingHints and Tips Cleaning the Oven Maintenance and CleaningOven lamp replacement Cleaning around the flame spreaderOven Cavity Oven ShelvesSomething Not Working Symptom SolutionGuarantee Conditions Service and Spare PartsParkinson Cowan Standard Guarantee conditions Customer CareScotland Channel IslandsNorthernireland WalesLondon & Eastanglia MidlandsSouth East South WestTechnical Data Instructions for the InstallerDimensions HobProvision for Ventilation Important Safety RequirementsLocation of the appliance Positioning the CookerFeet Assembly InstallationSplash back Assembly Positioning the Appliance FigFitting the Stability Bracket Not supplied Connecting to GasPermanent Connection Electrical connectionsCommissioning Minimum level adjustment of gas oven burner Replacement of gas oven burner nozzleConversion from Natural to LPG Gas Customer Care