For Universal LPG the regulator is fitted to the gas inlet of the appliance so that a pressure test point is available. The regulator should be disabled by adjusting the regulator adjusting screw to be fully screwed in, but do not remove the locking nut from the regulator. The supply pressure to the appliance is controlled by the regulator located on the LPG cylinder. This cylinder regulator should be adjusted to give a pressure of 2.75kPa at the appliance inlet with the large and simmer burners operating at maximum.

Use of Hose Assemblies.

If the appliance is to be installed using a hose assembly, then

1.The hose must be AGA certified to AS/NZS 1869 as class B or class D, and utilised in accordance with requirements of AS 5601 (AG 601).

2.The connection point between the consumer piping and the hose must be accessible with the appliance installed.

Typical Adjustment for Natural Gas

Adjusted for LPG

B2004

The wok-unit has a special pan support which enables use of a wok pot with curved bottom.

When using cooking utensils with a flat bottom the diameter of the utensils must not be less than 26 cm.

16

9

Image 9
Contents WK-m Page Table of contents Installing Safety informationChild Safety Maintenance and CleaningService ServiceDisposal Primary air intake apertureDescription of the product Technical data Units externally measured length Before leavingBurner cover/burner ring Use of Hose Assemblies Ignitions Gas installationMounting of Reinforcement Beams Cut-out measurementsStainless steel surfaces Cleaning of gas burnerCare must be taken to avoid boil-over Data label