Electrolux 3531 WK-M manual Ignitions, Gas installation

Page 10

Ignitions

1.Depress and turn the control knob for the burner, the left to Max. flame

2.The ignition electrode will emit sparks, and when the mixture of gas and air is correct, the burner will be ignited. Is not possible to connect the unit to mains, a match may be used to ignite the burner

3.After starting the burner, press the control knob for approx. 10 seconds to activate the automatic thermo couple.

4.Important Ignition position is at Max flame

Fixing

* Prepare the cut out according to the "cut out measurements”.

Connect the brass extension Piece to the bras elbow on the underside of hob.

*Screw the fixing brackets out to such an extent that they can be turned in under the table top.

Tighten the brackets on the to table top with an ordinary screwdriver.

Gas installation

The appliance is factory set for Natural Gas. Fit the gas regulator supplied with the appliance to the gas inlet. The location of the gas inlet is approximately 240mm form the right hand side of the appliance and 40mm from the back of the appliance. The connection of the Gas Regulator is ½” Gas female thread and the pressure at the test point should be adjusted to1.00kPa with the large and simmer burners operating at maximum.

For Universal LPG connection, the appliance needs to be first converted using the conversion kit and instructions supplied with the appliance.

10

15

Image 10
Contents WK-m Page Table of contents Child Safety Safety informationInstalling Maintenance and CleaningDisposal ServiceService Primary air intake apertureDescription of the product Technical data Before leaving Units externally measured lengthBurner cover/burner ring Use of Hose Assemblies Gas installation IgnitionsCut-out measurements Mounting of Reinforcement BeamsCare must be taken to avoid boil-over Cleaning of gas burnerStainless steel surfaces Data label