Change Basic Volume Settings

Note: All volume settings should be adjusted during normal or peak business hours. Adjusting them during slow times will likely produce volume settings that are too low.

Note: Inbound and outbound are always defined from the perspective of the headset.

Inbound Microphone Volume

Changing the inbound microphone volume affects the sound volume coming from the customer order point microphone. To turn up or down the inbound microphone:

1.Enter the configuration mode.

2.Select a new value for > The range is 0 (silent) to 20 (maximum).

Outbound Talk Volume

Changing the outbound talk volume affects the volume of the speaker at the customer order point.

Note: To avoid feedback, set the outbound talk volume as low as possible.

To change the outbound talk volume:

1.Enter the configuration mode.

2.Select a new value for > The range is 0 (silent) to 20 (maximum).

Vehicle Alert Volume

Changing the vehicle alert volume affects the volume of the vehicle alert signal on the headsets. To change the vehicle alert volume:

1.Enter the configuration mode.

2.Select a new value for > The range is 0 (silent) to 20 (maximum).

Outbound Greeter Message Volume

Changing the outbound greeter message volume affects the sound volume of the custom greeting messages and the system internal greetings (“Store Closed” and “Please Pull Ahead”). To turn up or down the greeter message volume:

1.Enter the configuration mode.

2.Select a new value for > The range is 0 (silent) to 20 (maximum).

Change the Monitor Volume

The monitor is an additional speaker that can be used to monitor drive-thru communication without a headset, typically in the kitchen. If the monitor has a volume control built into it, you can use it to control the overall volume level of the speaker. To be more specific about which elements you want to control, follow the instructions below.

Inbound Listen

Changing the inbound listen volume affects how loudly the monitor plays the inbound (customer order point) communication. You can also disable the monitor playing inbound sounds. To change the inbound listen monitoring settings:

1.Enter the configuration mode.

2.Select

3.To enable or disable the monitor playing the inbound sounds, change the value for to or

4.To change the volume level, select a new value for The range is 0 (silent) to 20 (maximum).

Night Volume

You can assign a standard reduction in the volume level of the customer order point speaker for night hours when lower volume is typically required. With the night volume set, the system automatically adjusts the volume during night hours, then back to normal during the day. To change the night volume setting:

1. Enter the configuration mode.

 

 

 

2. Select a new value for

 

>

 

The range is

 

 

0 (silent) to the current

day volume level

 

(maximum).

 

Note: Night Volume is never higher than Day Volume. Night volume reduction is a subtracted value, not the resulting level; therefore, if it is the same as the day volume level, the speaker will turn off at night. You cannot change the day outbound talk volume on this screen, only the reduction amount identified above.

6

Image 6
Contents 3M Drive-Thru Systems Indicator Mode Description Instructions for G5 Headset Controls and Battery ChargingG5 Headset Indicator Light Modes Headset ControlsRemoving Batteries G5 Battery Indicator Light ModesHeadset Cleaning Charging BatteriesRemove Replace Instructions for XT-1 Headset Controls and Battery ChargingOrder Taking Modes Tap the Talk button to talk to the customerEnter Configuration Mode Access Base Station Settings Greeter SetupChange Basic Volume Settings Change the Monitor VolumeNight Volume Registering Headsets G5 or XT-1 Change Site SchedulingStore is Now Closed Message Reboot SystemEnter the configuration mode Select Locating Base Station Serial Number
Related manuals
Manual 77 pages 6.15 Kb

G5, XT-1 specifications

The 3M G5 XT-1 is a cutting-edge respirator designed for professionals who require advanced protection in various hazardous environments. With its innovative features, this respirator stands out in the market, providing users with an optimal balance of safety, comfort, and performance.

One of the main features of the 3M G5 XT-1 is its advanced filtration technology. Equipped with highly efficient particulate filters, these respirators are designed to capture airborne particles, including dust, smoke, and other harmful contaminants. This effectiveness is further enhanced by the use of activated carbon in certain filter models, which provides an additional layer of protection against gases and odors. The filters are easy to replace, ensuring that users can maintain their equipment without hassle.

Another key characteristic of the G5 XT-1 is its ergonomic design. The respirator is engineered to provide an excellent fit, reducing the likelihood of leakage and ensuring that users receive optimal protection. The adjustable straps and customizable nose bridge allow for a snug fit on various face shapes and sizes, enhancing comfort during prolonged use. This is particularly important for professionals in fields such as construction, healthcare, and manufacturing, who may wear respirators for extended periods.

The G5 XT-1 also features a lightweight construction, which contributes to user comfort. This lightweight design, combined with features such as breathing valves, enhances airflow, reducing breathing resistance. This means that users can perform their tasks more efficiently while experiencing less fatigue.

Another notable technology integrated into the G5 XT-1 is its dual mode of operation. Users can switch between disposable and reusable options, which is particularly advantageous for those who want to balance cost and sustainability. The reusable aspect of the respirator also encourages environmental friendliness by reducing waste.

In conclusion, the 3M G5 XT-1 respirator is a comprehensive solution for those seeking high-performance respiratory protection. With its advanced filtration technologies, user-centric design, and flexible operation modes, the G5 XT-1 meets the diverse needs of professionals working in challenging environments. Its focus on safety, comfort, and adaptability secures its place as a top choice for respiratory protection in various industries.