About Rack Mounting
(Notes on Heat Dissipation)
The
When the
To ensure efficient cooling when rack mounting the
●Set up the unit in a site with good air circulation. In particular, make sure that there is nothing impeding the air flow that needs to reach the rear panel's air vent.
●Never mount the
When the heated air inside the rack cannot be expelled, it is recirculated through the intakes, preventing effi- cient cooling of the amp.
●When mounting multiple amps, make sure that there is sufficient ventilation (especially within the rack), and also make sure that the exhaust air does not get recir- culated back to the intakes. If there is no way to keep the rear panel of the amp away from the rack, then make sure the rack has an opening or fan installed for ventilation of the heated air that builds up during oper- ation.
●Provide at least 1U (1.75 inches) of open rack space between each three
●When stored in portable racks, remove the front and rear covers of the case before operation, so that the front and rear panels of the
●If the Thermal Protection Circuit is activated, and the PROTECTION indicator lights, you must then take measures to improve heat dissipation. Reconsider the type of installation and rack environment you are pro- viding for the
●When mounting the
Attaching the Rubber Feet (Included)
Attach the rubber feet included with the
Bottom Chassis