CONVERSION & ORIFICES INFORMATION
BAKE BURNER
ADJUSTMENTS
Loosen
Air Adjustment
Shutter
Air Adjustment
Shutter
Loosen
BROIL BURNER ADJUSTMENTS
6Open the bake and broil air shutter adjustments as far as possible and adjust later if necessary.
Beneath the bake and broil burner orifice hoods are LP orifice needles. To convert to L.P. tighten the orifice hoods against the orifice needle until the hoods are snug
BURNER OUTPUT RATINGS; BTU/HR
NATURAL GAS with 4" W.C.P.
Burner | BTU Rate | Orifice Size |
|
|
|
LF, RF | 12,000 | 1.68 mm (III) |
|
|
|
LR | 9,500 | 1.50 mm (II) |
|
|
|
RR | 5,000 | 1.07 mm (I) |
|
|
|
BAKE | 16,000 | #47 (.0785") |
|
|
|
BROIL | 13,500 | (.069") |
|
|
|
175Natural gas surface
N | orifices are marked |
III | on top as shown |
|
ORIFICE INFORMATION
JGBP85BEA Orifice Charts
TOP BURNER ORIFICES
LR | RR |
LF | RF |
LP
GAS
Front of Range
The top burner orifices each have a series of marks engraved on the tops of the orifices (I, II, III) to denote their location. The marks appear on both the Natural and LP gas orifices. The location indicated by the marks, is the same for both gases.
See BURNER OUTPUT RATING charts at right for locations.
BURNER OUTPUT RATINGS; BTU/HR
LP (PROPANE) GAS with 10" W.C.P.
Burner | BTU Rate | Orifice Size | ||
|
|
|
| |
LF, RF | 11,000 | .94L mm | (III) | |
|
|
|
| |
LR | 9,500 | .89L mm | (II) | |
|
|
|
|
|
RR | 5,000 | .63L | MM | (I) |
|
|
|
| |
BAKE | 16,000 | #56 | (.0465") | |
|
|
|
| |
BROIL | 12,000 | #59 | (.041") | |
|
|
|
|
|
90LP gas surface
L | orifices are marked |
III | on top as shown |
|
SMALLER ORIFICES FOR HIGHER ELEVATIONS
Burner | Size | Part Number | L.P. | Natural |
|
|
|
|
|
LF & RF | 1.65 mm | WB02X9841 |
|
|
|
|
|
|
|
LF & RF | .84 mm | WB02K0022 |
|
|
|
|
|
|
|
LR | 1.44 mm | WB06K0094 |
|
|
|
|
|
|
|
LR | .73 mm | WB19K5000 |
|
|
|
|
|
|
|
IMPORTANT NOTE: Always consult the Technical Service literature
– 12 –
LP ORIFICE COLOR ID
Burner | BTU Rate | Color |
|
|
|
LF & RF | 11,000 BTU | Blue / Magenta |
|
|
|
LR | 9,500 BTU | Blue / Brown |
|
|
|
RR | 5,000 BTU | Blue / Blue |
|
|
|
Paint color codes have been added to the sides of the LP orifices to aid in identifying the proper orifice location during conver- sion.