CONTROL PANEL ACCESS

FLIP PANEL UP TO ACCESS

FLUORESCENT LIGHT

A

HINGED ON

BACK SIDE

REMOVE 2 SCREWS

TO REMOVE CRYSTAL

END

SIDE

CAP

FRAME

 

TO REMOVE CONTROL PANEL

1. Grasp the light panel cover at the rear,

where it is hinged to the control panel. Lift

upward at the rear, just far enough to insert

a small, thin bladed screw driver between

the end cap and the fluorescent light cover.

Slide the blade forward toward the front

while lifting upward on the cover. Be sure to

wrap the blade of the screw driver with tape

so as not to scar the plastic shield.

2. Remove screws A & B, which secure the

endcaps to the control console. Be careful

when removing the endcap not to break the

locating tab at the bottom of the endcap.

B

BE SURE TAB IS

IN SLOT WHEN

REINSTALLING

VENT DEFLECTOR

Pull control panel down and forward to release it from the vent deflector

C

LOOSEN THIS SCREW TO RAISE CONTROL PANEL

3. LOOSEN screw C . DO NOT REMOVE.

This screw is just long enough that it will

protrude into a slot in the side frame,

causing the panel to bind as you slide it

down and forward. Loosening the screw a

couple of turns will back it off enough that it

will no longer protrude into the side frame

slot.

4. Grasp the face panel at the bottom front with

one hand, while gently pushing down on the

top of the control panel with your other. Pull

panel downward to release it from the vent

deflector while at the same time pull the

REINSTALLING CONTROL PANEL

When reinstalling the control panel, push up on the vent lip with your fingers. At the same time pull forward on the control panel, making sure that the vent lip is TUCKED UNDER the control panel while lowering the panel into place.

TUCK VENT LIP UNDER CONTROL

PANEL PRIOR TO LOWER PANEL

LOWER PANEL

INTO PLACE

PUSH UP ON

VENT LIP

SPARK MODULE

The spark module is located behind the control panel, on the right side. You must remove the control panel to access the spark module.

BALLAST

SPARK

MODULE

TABS

– 13 –

Image 15
Contents Technical Service Guide Important Safety Notice Table of Contents Featured Model About this Technical Service Guide Featured ModelJGBP85BEA Full Range of Power GE TrueTemp Only GE GAS Ranges have AN Appetite this BIG Weve PUT a NEW Spin on a Grate TOP So Whats New? NEW Features / Design30 XL44 SELF-CLEANING GAS Ranges 30 XL44 Continuous and Standard Clean GAS Ranges To Raise or Remove Cook TOP Cook TOP / Surface BurnersConversion to LP Propane GAS LOW Flame Simmer AdjustmentsOrifice Information Bake Burner AdjustmentsBroil Burner Adjustments Conversion & Orifices InformationCAP Control Panel AccessReinstalling Control Panel ENDERC ERC III Special FeaturesChanging the Speed of the + or Pads on Some Models Fahrenheit or Centigrade TemperatureHelpful USE and Care Information Cook and HoldMost Accurate Oven In America Thermostat CyclingHOW Fault Codes are Stored in Memory Example ERC Fault Code Memory TestERC Fault Code Memory Display HOW to Display the Fault Codes in MemoryHOW to Perform the Tests ERC Diagnostic TestsERC on Board Diagnostic Tests HOW to Enter and Exit the Diagnostic ModeLock Motor Access Lock Motor CircuitDoor Latch Mechanism PCB ERC D1 R RK SW O D3 O JGBP85BEA Strip CircuitsFailure Codes F Codes JGBP85BEA Diagnostic InfoERT Control Voltages JGBP30BEA SchematicJGBP30BEA Strip Circuits JGBP85BEA JGBP85BEA JGBP85BEA JGBP85BEA Model JGBP85BEA1BB Illustrated Parts CatalogVent ASM Glow BAR XL44 Gas Ranges