Stow manual Stow T-30H Safety Message Alert Symbols

Page 6

STOW T-30H — SAFETY MESSAGE ALERT SYMBOLS

FORYOUR SAFETY AND THE SAFETY OF OTHERS!

HAZARD SYMBOLS

Safety precautions should be followed at all times when operating this equipment. Failure to read and understand the Safety Messages and Operating Instructions could result in injury to yourself and others.

 

This Owner's Manual has been

 

developed to

provide complete

 

instructions for the safe and efficient

 

operation of the STOW Model T-30H

NOTE

Trash Pump. Refer to the engine

 

manufacturers instructions for data

 

relative to its safe operation.

 

Before using these pumps, ensure

 

that the operating individual has

 

read and

understands all

 

instructions in this manual.

SAFETY MESSAGE ALERT SYMBOLS

The three (3) Safety Messages shown below will inform you about potential hazards that could injure you or others. The Safety Messages specifically address the level of exposure to the operator, and are preceded by one of three words: DANGER, WARNING, or CAUTION.

DANGER: You WILL be KILLED or

SERIOUSLY injured if you do not follow

WARNING: You CAN be KILLED or

SERIOUSLY injured if you do not follow directions.

CAUTION: You CAN be injured if you do not follow directions.

Potential hazards associated with the STOW T-30H Trash Pump operation will be referenced with Hazard Symbols which appear throughout this manual, and will be referenced in conjunction with Safety Message Alert Symbols.

Lethal Exhaust Gases

Engine exhaust gases contain poisonous carbon monoxide. This gas is colorless and odorless, and can cause death if inhaled. NEVER operate this equipment in a confined area or enclosed structure that does not provide ample free flow air.

Explosive Fuel

GASOLINE is extremely flammable, and its vapors can cause an explosion if ignited. DO NOT start the engine near spilled fuel or combustible fluids. DO NOT fill the fuel tank while the engine is running or hot. DO NOT overfill tank, since spilled fuel could ignite if it comes into contact with hot engine parts or sparks from the ignition system. Store fuel in approved containers, in well-ventilated areas and away from sparks and flames. NEVER

Burn Hazards

Engine components can generate extreme heat. To prevent burns, DO NOT touch these areas while the engine is running or immediately after operations. Never operate the engine with heat shields or heat guards removed.

Rotating Parts

NEVER operate equipment with covers, or guards removed. Keep fingers, hands, hair and clothing away from all moving parts to prevent injury.

PAGE 6 — STOW T-30H TRASH PUMP — PARTS MANUAL — REV. #0 (05/30/03)

Image 6
Contents Model T-30H Trash Pump 2 Stow T-30H Trash Pump Parts Manual REV. #0 05/30/03 Heres HOW to GET Help Stow T-30H Table of Contents Parts Ordering Procedures When ordering parts Please supply the following informationStow T-30H Safety Message Alert Symbols Accidental Starting General Safety Rules for Safe OperationRules for Safe Operation Specifications Pump Specifications Engines STOWT-30H General Information ApplicationStow T-30H Pump Components Stow T-30H Basic Engine Initial ServicingStow T-30H PRE-INSPECTION Engine Stow T-30H PRE-SETUP Pump Read safety instructions at the beginning of manualStow T-30H Initial START-UP Engine Stow T-30H Initial START-UP Engine Stow T-30H Trash Pump Parts MANUAL- REV 05/30/03 Stow T-30H Maintenance Pump Pump Vacuum TestStow T-30H Maintenance Pump Stow T-30H Maintenance Engine Engine Maintenance ScheduleStow T-30H Maintenance Engine STOWT-30H Preparation for Long -TERM Storage Pump StorageStow T-30H Trash Pump Parts MANUAL- REV 05/30/03 Troubleshooting Engine STOWT-30H Troubleshooting ENGINE/PUMP STOWT-30H Explanation of Code in Remarks Column Items Found In the Remarks ColumnStow T-30H Suggested Spare Parts Qty DescriptionStow T-30H Pump Assy Pump Assy 32 Stow T-30H Trash Pump Parts Manual REV. #0 05/30/03 Part Name Honda GX240K1PMT2 Engine AIR Cleaner Dual Assy AIR Cleaner Assy Honda GX240K1PMT2 Engine Camshaft Assy Camshaft Assembly Honda GX240K1PMT2 Engine Carburetor Assy Gasket SET Honda GX240K1PMT2 Engine Control Assy ARM, Governor Honda GX240K1PMT2 Engine Crankcase Cover Assy NO. Part no Honda GX240K1PMT2 Engine Crankshaft Assy 13310ZE2651 Honda GX240K1PMT2 Engine Cylinder Barrel Assy SHAFT, Governor ARM Honda GX240K1PMT2 Engine Cylinder Head Assy Part Name QTY. Remarks Honda GX240K1PMT2 Engine FAN Cover Assy CLIP, Tube Honda GX240K1PMT2 Engine Flywheel Assy FAN, Cooling Honda GX240K1PMT2 Engine Fueltank Assy RUBBER, Supporter 107MM Honda GX240K1PMT2 Engine Ignition Coil Assy Coil ASSY., Ignition Honda GX240K1PMT2 Engine Muffler Assy PIPE, Exhaust Honda GX240K1PMT2 Engine Piston Assy Ring SET, Piston 0.75 Optional Honda GX240K1PMT2 Engine Recoil Starter Assy PULLEY, Recoil Starter 64 Stow T-30H Trash Pump Parts Manual REV. #0 05/30/03 Honda GX240K1PMT2 Engine Gasket KIT Assy Honda GX240K1PMT2 Engine Labels Assy Emblem Internal Effective October 1, 2002 Terms and Conditions of Sale Parts Stow T-30H Trash Pump Parts MANUAL- REV 05/30/03 Please have the Model and Serial Number ON-HAND When Calling

T-30H specifications

The Stow T-30H is an advanced stadium and event venue turbine heater that combines efficiency, performance, and cutting-edge technology, making it a preferred choice for a range of applications. Designed specifically to provide optimal heating solutions in large spaces, the T-30H stands out due to its unique features and functionalities.

One of the primary features of the Stow T-30H is its robust heating capacity. With a heating output that can reach up to 30 kW, the unit is capable of efficiently warming areas of significant size. This makes it particularly suitable for indoor sporting events, exhibition halls, and outdoor venues during the colder months. The heater is also engineered to quickly and effectively raise the temperature in a controlled manner, ensuring that users remain comfortable in any setting.

The T-30H incorporates innovative technology designed to maximize its efficiency. It utilizes an advanced combustion system that not only improves fuel consumption but also minimizes emissions. This eco-friendly approach aligns with modern sustainability goals, making the heater an attractive choice for organizations aiming to reduce their carbon footprint.

The ease of operation is another noteworthy characteristic. The Stow T-30H features a user-friendly control panel that allows operators to set and adjust the heating levels conveniently. Additionally, it includes built-in safety mechanisms, such as overheat protection and flame failure detection, ensuring safe operation at all times.

Portability is key in the design of the T-30H. The unit is equipped with durable wheels and a compact profile, allowing for easy transportation and set-up across different locations. This makes it an ideal solution for event organizers who need a heating solution that is both efficient and flexible.

Furthermore, the Stow T-30H is compatible with various fuel sources, offering versatility for users. With options for propane, natural gas, and diesel, it can cater to diverse operational needs and preferences.

In summary, the Stow T-30H delivers powerful heating capabilities combined with modern technology and user-friendly operation. Its focus on efficiency, safety, and portability makes it an excellent choice for stadium and event venue heating needs, ensuring comfort for participants and audiences alike. With this remarkable heater, organizations can enhance the experience of their events, no matter the season.