Belkin belkin bulldog plus- shutdown management software for windows Networking, Operation Mode

Page 11
Networking

Networking

BULLDOG Plus software is comprised of two modules: BULLDOG Service and BULLDOG Monitor. You may run both the programs in a computer to monitor your localized UPS or run the programs in two different computers.

Operation Mode:

BULLDOG Service can operate in "Master" Mode (which allows BULLDOG to send commands to its connected UPS) in "Serial Slave" mode (which listens to its connected UPS) or in "Networking Slave" mode (which obtains the UPS information from Master via the network). If two or more computers are communicating with a single UPS, only one of these computers should be in Master mode; the others should be in Slave mode to prevent them from sending contradictory commands.

When a power event occurs, the Master gets the information then transmits it to Salve(s). Each BULLDOG Service executes different "Actions"(FlexEvent) so that the system manager can configure different strategies into each different computer. For example: When a power failure occurs, the file server and mail server won't shutdown until the UPS battery is low, but other less important workstations execute shutdown after 5 minutes, and the initial workstations shutdown after 10 minutes. Shutting down workstations preserves more battery power for your mission critical network servers.

Remote Monitoring and Control:

Bulldog Monitor has the ability to monitor Local hosts and Remote hosts.

Belkin Components

11

Image 11
Contents for Windows User’s Manual Belkin Bulldog PlusShutdown Management Software 錯誤! 尚未定義書籤。 Table of ContentsBULLDOG PLUS MONITOR OPERATIONS VIEW ADVANCED UPS PROPERTYNETWORK CONTROLTime SERVICE AND SUPPORTDiagram UPS TreeIntroduction Bulldog Plus featuresBulldog Plus Setup Bulldog Plus InstallationBulldog Plus Service Monitor Run the Bulldog Plus user interface Bulldog Plus Monitor Bulldog Monitor Main Screen Remote Monitoring and Control NetworkingOperation Mode Page Communicator, type the IP address in the URL and press enter Top Layer Buttons Bulldog Plus Monitor OperationsBulldog Monitor Main Menu System LoginWindow Monitor ScreenFont Close Monitor Configuration Window ConfigurationBulldog Service Mode Bulldog Service acts as a Master or Slave Notifify Users --Network Broadcast DevicesNotification Users --Pager List Notification Users -- e-mailb. Change Change the color you have selected Closec. Default Default setting Close the Configuration windowAttached Devices UPS PropertySchedule Log ManagementAction Action - Logging Action - ShutdownAction - Paging Action- CommandAction - Alarm Action - BroadcastingTransfer Voltage Action - Receptacle ControlStop All Action Voltage SensitivityAdvanced UPS Property Choose Master/Slave Set PasswordNetwork Wake On LAN SNMP Description SNMP Trap NumberVariable Trap NoDupsNoLongerEnvOverHumidity HTTPDupsEnvOverHumidity WARNING The environment over normal humidityShutdown Now Cancel ShutdownControl Cancel Test UPS Audible Alarm OnUPS Audible Alarm Off Deep Battery TestEvent Log ViewMeters b. Exit Closes event log dialog box History Grapha. Print Prints the event log Auto Save History DataRemote Hosts Main Bottom Layer ButtonsStatus DiagramUPS Tree TimeFrance Service and SupportCorporate Headquarters United KingdomChina The NetherlandsAustralia Tech Support Customer Service/Sales china@belkin.com