Berkel FMS60 manual Cleaning, Remove Bowl Guard / Wire Cage, Install Bowl Guard / Wire Cage

Page 8

BOWL GUARD / WIRE CAGE

Bowl Guard/Wire cage must be in position and closed in order to mix. If Bowl Guard/wire cage is opened during the mixing, mixer will stop.

REMOVE BOWL GUARD / WIRE CAGE

Lower the bowl support and remove agitator before removing bowl guard/wire cage. Hold wire cage with both hands and pull downward gently to release from retainer (Fig. 5).

INSTALL BOWL GUARD / WIRE CAGE

Hold Bowl Guard/wire cage with both hands and gently push upward until bowl guard/wire cage is latched on the retainer and can be rotated freely (Fig. 5).

Fig. 5

CLEANING

disconnect the electrical power to the mixer before beginning any cleaning

procedures.

The mixer should be thoroughly cleaned daily.

Bowls and agitators should be removed from the mixer and cleaned in a sink.

DO NOT use a hose to clean the mixer — it should be washed with a clean damp cloth. Clean the bowl guard/wire cage by wiping with a cloth or sponge and warm soapy water. DO NOT place agitators, attachments or mixer components in a dishwasher for cleaning.

FMS60 Owner/Operator Manual

– 8 –

Image 8
Contents Model FMS60 Table of Contents Installation GeneralUnpacking LocationElectrical Connections Operation FMS60 Owner/Operator Manual Agitator MixingBowl Cleaning Bowl Guard / Wire CageRemove Bowl Guard / Wire Cage Install Bowl Guard / Wire CageMixing Bowl Capacity Chart Kitchen Materials Capacity Chart Finished MaterialsMaintenance Agitators and AccessoriesMotor Bowl Lift SlidewaysService and Parts Information Warranty