Section 300-Installation

Chapter 5. Peripheral Equipment

 

 

 

 

Table 5-11. Maximum distances for SLTA installation

 

 

 

 

 

 

Wiring

Max. distance (in feet) between

Max. distance (in feet) between

 

gauge

the DBS and SLTA

the SLTA and the SLT

 

 

 

 

 

AWG 22

300’ or 10 W

3000’ or 100 W

 

 

 

 

 

AWG 24

190’ or 10 W

1900’ or 100 W

 

 

 

 

 

AWG 26

120’ or 10 W

1200’ or 100 W

 

 

 

 

 

4.If the DBS is powered up, turn off the power.

5.Connect the GND and +24V leads on the SLTA to the DBS connector panel. Be sure the wires do not touch each other or touch the metal frame housing.

6.Turn on the DBS power.

7.Connect the “T” and “R” leads to the digital extension ports on the DBS as per Figure 5-21.One digital extension port is required for each SLT.

8.Connect the SLT “T” and “R” leads to the SLTs.

9.Install the cover on the SLTA.

DBS-2.3/9.2-300

DBS Manual - Revised April 2000

5-35

Page 129