Chapter 4. Trunks and Lines

Section 300-Installation

 

 

4. Set SW1 on the T1 card according to the following table.

These switch settings correspond to the distance between the DBS and the

CSU. To turn a switch on, flip it to the “up” position.

Table 4-18. Switch settings for SW1 on the T1 card

SW

Distance from the DBS to the CSU

 

 

 

 

 

0 to 150 ft.

150-450 ft.

450-655 ft.

 

 

 

 

SW1

On

Off

Off

 

 

 

 

SW2

Off

On

Off

 

 

 

 

SW3

Off

Off

On

 

 

 

 

SW4

Off

On

Off

 

 

 

 

SW5

Off

Off

On

 

 

 

 

SW6

Off

On

Off

 

 

 

 

SW7

Off

Off

On

 

 

 

 

SW8

Not used

Not used

Not used

 

 

 

 

5.Install the T1 card in the “EC/TRK” slot

6.Connect the Sync Cable from CN1 on the Sync Unit to CN5 on the T1 card.

Figure 4-8. Sync Unit and T1 connection, single-cabinet installation

TR K

D EC

D EC

D EC

D EC

D EC

D EC

D EC

D EC

T1

SCC

CPC

M FR

 

 

 

 

 

 

 

 

 

 

TR K

 

 

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

O

 

 

 

 

 

 

 

 

 

 

 

 

 

T

S .U .

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

U

C N 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

Sync.U nit

 

 

 

 

 

 

 

 

 

Sync Cable

 

 

 

C N 5

 

 

 

 

 

 

 

 

 

 

 

 

7.Connect the cable attached to CN3 on the T1 MDF card to CN3 on the T1 card (Figure 4-10).

8.Using an RJ48 cable, connect CN1 on the T1 MDF card to the CSU (Figure 4-10). The following illustration shows CN1 pinouts.

 

 

 

 

4-24

DBS Manual - Revised April 2000

DBS-2.3/9.2-300

Page 72
Image 72
Panasonic CPC-EX manual Distance from the DBS to the CSU, To 150 ft 150-450 ft 450-655 ft