Section 300-Installation

 

 

 

 

 

Chapter 5. Peripheral Equipment

 

 

 

 

 

 

 

 

 

 

 

Table 5-7. Switch settings for delay answer timing, VAU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch Block 2 (SW2)

 

 

 

 

 

 

 

Delay Answer Timer (Switches 1-3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch

 

 

 

Timer (in seconds)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

8

12

16

20

24

28

No Answer

 

 

 

 

 

 

 

 

 

 

(VAU 1.1 or

 

 

 

 

 

 

 

 

 

 

below) or

 

 

 

 

 

 

 

 

 

 

Immediate

 

 

 

 

 

 

 

 

 

 

Answer (VAU

 

 

 

 

 

 

 

 

 

 

1.2 or above)

 

 

 

 

 

 

 

 

 

 

 

 

1

OFF

OFF

OFF

OFF

ON

ON

ON

ON

 

 

 

 

 

 

 

 

 

 

 

 

2

OFF

OFF

ON

ON

OFF

OFF

ON

ON

 

 

 

 

 

 

 

 

 

 

 

 

3

OFF

ON

OFF

ON

OFF

ON

OFF

ON

 

 

 

 

 

 

 

 

 

 

 

Table 5-8. Switch settings for DTMF detection timing, VAU

DTMF Detection Timer

VAU

Switch

Function

Version

block and

 

 

switch

 

 

 

 

1.1 or above

SW2, pin 4

ON=80 ms

 

 

OFF=40 ms

 

 

 

1.0 or below

SW1, pin 1

Where X/X=SW1 setting/SW2 setting:

 

and SW2,

ON/ON=40

 

pin 4

 

OFF/ON=60

 

 

 

 

ON/OFF=80

 

 

OFF/OFF=100

 

 

 

Table 5-9. Switch settings for wait timing between dialed digits, VAU

Switch Block 2 (SW2)

Wait Time Between Dialed Digits (Switches 5-6)

Switch

 

Time (in seconds)

 

 

 

 

 

2

6

10

14

 

 

 

 

 

 

5

OFF

OFF

ON

ON

 

 

 

 

 

6

OFF

ON

OFF

ON

 

 

 

 

 

DBS-2.3/9.2-300