Chapter 5. Peripheral Equipment | Section |
|
|
Paging
The DBS allows extensions to be grouped into paging groups numbered 00-
07.When you issue a page (by dialing
External zone paging allows you to connect up to five speaker groups to the DBS. Each speaker group is assigned to one of five paging zones
If zone paging is not required, general paging relay terminals C (common), B (break) and M (make) are also provided. The relay terminals activate any time there is a page to an external page group. These are used when paging and UNA use the same paging amplifier system. (See notes for more information.)
Guidelines
•The paging amplifier, zone relays, and speakers are not provided with the DBS. They must be purchased separately.
•The maximum current for each zone paging terminal on the Connector Panel
•The contact rating for the UNA/General Paging “C” and “M” terminals is 30V DC, 1 amp (maximum).
•Connector 4 (CN4) on the Connector Panel is used to connect the paging amplifier. The output impedance of CN4 is 600 Ohms; the loss/gain setting is 0 dB.
External Page Zone Installation
1.Connect the paging amplifier to CN4 on the DBS Connector Panel. (See Figure
2.Connect the paging speakers to the amplifier and relays.
|
|
|
|