Section 300-Installation

Chapter 6. Double-Cabinet Systems

 

 

Guidelines

Two DBS cabinets can be connected to increase line size. The maximum line size consists of two DBS 96 cabinets, which provide 192 ports.

CPC-B and SCC-B are required for two-cabinet systems.

If ground start or DID trunks are used in both cabinets, separate -48V supplies must be supplied for each cabinet. If AECs are used in both cabinets, separate SLT ringer boxes must be supplied for each cabinet.

The following table shows the acceptable combinations of system types

Table 6-1. Trunk and extension port maximums for double-cabinet systems

System

 

 

 

 

Combinations

Trunk

Extension

Expansion Ports

 

 

 

 

 

Master

Slave

Ports

Ports

(Trunk lines or

 

 

 

 

extensions)

 

 

 

 

 

DBS 40

DBS 40

16

48

8 (See Note 1.)

 

 

 

 

 

DBS 72

DBS 40

24

72

0 (See Note 2.)

 

 

 

 

 

DBS 72

DBS 72

32

96

8 (See Note 1.)

 

 

 

 

 

DBS 96

DBS 40

32

88

16

 

 

 

 

 

DBS 96

DBS 72

40

112

16

 

 

 

 

 

DBS 96

DBS 96

48

128

16

 

 

 

 

 

Notes:

 

 

 

 

1. The slave cabinet must be used for expansion ports.

2. When a DBS72 and DBS40 are connected, expansion ports cannot be used.