Section | Chapter 6. |
|
|
Guidelines
•Two DBS cabinets can be connected to increase line size. The maximum line size consists of two DBS 96 cabinets, which provide 192 ports.
•
•If ground start or DID trunks are used in both cabinets, separate
•The following table shows the acceptable combinations of system types
Table
System |
|
|
|
|
Combinations | Trunk | Extension | Expansion Ports | |
|
|
|
|
|
Master | Slave | Ports | Ports | (Trunk lines or |
|
|
|
| extensions) |
|
|
|
|
|
DBS 40 | DBS 40 | 16 | 48 | 8 (See Note 1.) |
|
|
|
|
|
DBS 72 | DBS 40 | 24 | 72 | 0 (See Note 2.) |
|
|
|
|
|
DBS 72 | DBS 72 | 32 | 96 | 8 (See Note 1.) |
|
|
|
|
|
DBS 96 | DBS 40 | 32 | 88 | 16 |
|
|
|
|
|
DBS 96 | DBS 72 | 40 | 112 | 16 |
|
|
|
|
|
DBS 96 | DBS 96 | 48 | 128 | 16 |
|
|
|
|
|
Notes: |
|
|
|
|
1. The slave cabinet must be used for expansion ports.
2. When a DBS72 and DBS40 are connected, expansion ports cannot be used.
• Figures 6-1 through 6-6 shows slot usage for two-cabinet combinations.
DBS Manual - Revised April 2000 |