Chapter 5. Peripheral Equipment

Section 300-Installation

 

 

Off-Premises Adaptor (OPX)

Guidelines

Analog phones can be connected as off-premise stations through a direct line to the DBS or through the central office, depending on how far the stations are from the OPX Adaptor.

Table 5-4shows how far the OPX stations can be from the adaptor without going through a CO.

Table 5-4. Maximum distances for direct connection to OPX stations

Wiring

Max. distance (in feet) between

gauge

the OPX Adaptor and the OPX

 

station

 

 

AWG 22

27877

 

 

AWG 24

17532

 

 

AWG 26

11025

 

 

One OPX Adaptor (VB-43702) is required for each OPX station.

The ringing output of the OPX Adaptor is 225 Vp-p (peak-to-peak) at 20 Hz.

When OPX stations are connected through the central office, an external ringer supply may be required. If required, the ringing supply is connected to the OPX Adaptor.

Order an OL13C circuits for OPX stations connected through a CO.

The following tools are required to install the OPX Adaptor:

-Phillips screwdriver

-Needle-nose pliers

-Diagonal shears.

 

 

 

 

5-10

DBS Manual - Revised April 2000

DBS-2.3/9.2-300

Page 104
Image 104
Panasonic CPC-EX manual Off-Premises Adaptor OPX