Section 300-Installation

Chapter 4. Trunks and Lines

 

 

Installing T1 in a Double Cabinet with the T1 in the Slave

1.Install the Sync Unit in the master cabinet as described in Steps 1 and 2 under “Installation for a Single T1.”

2.Install a T1 MDF card in the slave cabinet. (See Step 3 on page 4-23.)

3.Set Switch 1 on the T1 card. (See Step 4 on page 4-24.)

4.Install a T1 card in the “EC/TRK” slot of the slave cabinet.

5.Connect the Sync Cable from CN1 on the Sync Unit to CN5 on the T1 card (Figure 4-11).

Note: Part Number VB-43564 is used for the Sync Cable when a T1 is installed only in the slave cabinet of a two-cabinet system.

6.At the slave cabinet, connect the cable attached to CN3 on the T1 MDF card to CN3 on the T1 card (Figure 4-10).

7.Using an RJ48 cable, connect CN1 of the T1 MDF card to the CSU. (See Figure 4-9 on page 4-25for RJ48 pinouts.)

8.At the slave cabinet, connect the ground cable on the T1 MDF card as shown in Figure 4-10 on page 4-26.

DBS-2.3/9.2-300

DBS Manual - Revised April 2000

4-27