INSTALLATION
Plumbing Connections
CAUTION:
!Plumbing connections must comply with local sanitary and plumbing codes.
Water Connections
1.Connect the hot water supply (60°C/ 140°F Min) to the 1/2" I.D. fill hose provided. The fill solenoid valve is equipped with a flow control that will accept water pressures from 172 kPa/25 psi to 665 kPa/95 psi.
2.Install a manual
3.The fill solenoid valve is equipped with a
Drain Connections
1.All Models are supplied with a flexible 5/8" I.D. drain hose, which must be connected to a
2.Drain connections height should be a maxium of 3 feet from the from the floor.
Detergent/Chemicals
Use a qualified detergent/chemical supplier for your detergent, rinse aid, and chemical sanitizer needs.
1.Your machine has a liquid detergent dispensing pump. Insert the labeled detergent pickup tube into the detergent container. The pickup tube has a strainer on the end to prevent crystallized chemical from clogging the supply lines.
2.The cycle timer located in the main control cabinet is equipped with adjustable cams for the chemical dispensing pump(s). The cams control the length of time that the pumps operate. A qualified person may adjust the cam settings if necessary. Refer to the timer chart diagram(s) at the end of the manual for timer cam locations. Factory time settings are only approximate. Have your chemical supplier check the concentration and make the necessary adjustments.
NOTE:
A nonchlorinated detergent is recommended for your dishwasher.
Rinse Aid
1.A rinse aid pump is included on all models. Insert the labeled Rinse Aid pickup tube into the rinse aid container. Contact your chemical supplier for adjustment to ensure proper dosage.
Chemical Sanitizer
1.Model
2.Contact your chemical supplier for adjustment of the chemical sanitizer to ensure proper dosage.
6