MAINTENANCE

Maintenance Schedule

As Required

1.Check the temperature gauge reading to make sure that it is accurate.

2.Check the chemical supplies and refill as necessary.

Weekly

1.Inspect all water lines for leaks and tighten them at joints if required.

2.Clean all detergent residue from the exterior of the machine.

3.Check the drain for leaks.

4.Remove and closely inspect the spray arms for blockage.

5.Check for damage to the scrap screen. Ineffective screening can cause wash system failures, or poor washing results.

6.Clean the detergent, sanitizer, and rinse aid supply tubes. Complete the following procedure:

a.Remove the detergent, sanitizer, and rinse aid pick-up tube(s) from the container(s). Place the tube(s) into a container of hot water.

b.Ensure ON/FILL/OFF/DRAIN switch is in the ON position depress and hold the DET prime switch (located on the front panel) until clear water enters the tank through the fill air gap (located on the right side of the tank).

c.Your machine is equipped with a sanitizer and/or rinse aid pump, follow the same procedure by pressing the SANITIZER and/or the RINSE AID prime switch until clear water enters the tank through the fill air gap.

d.When completed, remove the pickup tubes from the hot water and reinsert them into the correct chemical containers. Repeat the priming procedures to ensure that chemicals have filled the tubes for the next operating period.

e.Run a complete cycle to flush chemicals from the tank.

11

Image 17
Contents Technical Manual Copyright 2003 by Moyer Diebel Revision History This Intentionally Left Blank Contents Detergent Pump Assembly Introduction Limited Warranty Standard equipment includes GeneralL1L2N G Electrical Connections InstallationUnpacking Detergent/Chemicals Plumbing ConnectionsRinse Aid Chemical SanitizerCompleting Installation Operation Summary Daily Operation ProceduresOperation Operation Cleaning Schedule MaintenanceAs Required Maintenance ScheduleDeliming Deliming ProcedureCondition Cause Solution TroubleshootingThis Intentionally Left Blank Replacement Parts Track and Panel Assembly Part Door and Switch Assembly 0501412 Screw, 10-32 x 3/8 Truss Head 0308596 Tank/Drain Assembly 0508628 Pump Assembly 0502704 Wash System Assembly 0508549 Booster Assembly and Water Inlet Piping HT Plus Only Booster Assembly and Water Inlet Piping HT Plus only Water Inlet Piping HTN PLUS, LT Plus Only 0503718 Fill System 107417 Hose, 1/2 I.D. HTN PLUS, LT Plus 0501518 Rinse Aid DETERGENT/RINSE AID Pump Assembies HT PLUS, HTN Plus Detergent/Sanitizer/Rinse-Aid Pump Assembly LT Plus Only DETERGENT/SANITIZER/RINSE-AID Pump Assemblies LT Plus only Control Panel Assembly 0501379 This Intentionally Left Blank Electrical Schematics 0510652 0510653 0510654 Timer Assembly 401-HTM2 Timer Assembly 401-LTM2