Moyer Diebel 401-HTM2 PLUS, 401-HTNM2 PLUS, 401-LTM2 PLUS technical manual 0510653

Page 47

ELECTRICAL SCHEMATICS

CUSTOMER TO SUPPLY RATED

VOLTAGE/PHASE/Hz, AS SPECIFIED

PER ORDER, TO DISCONNECT SWITCH.

ALL POWER SUPPLIED TO EACH CONNECTION

POINT MUST COMPLY WITH ALL LOCAL

ELECTRICAL CODES.

TO CUSTOMER RECEPTACLE

115V 60Hz

BLK WHT

GND

1

MSW

34

ON

1

 

 

 

 

4

 

5

NO

OFF

CAM 8

 

NC

6

NONO

CAM 1

NC 7 NC

1CR

12

 

 

8

 

 

 

 

 

 

 

CLT

 

 

 

 

 

8

 

8

8

 

 

 

 

 

 

 

TM

 

 

 

 

 

 

 

 

WASH/

BLU

START CW

 

 

 

 

13

/RINSE

 

 

9

9 L SRC S 12

NO

 

 

1

 

 

CAM 3

 

 

 

 

 

NO

 

 

 

RED

START CCW

8

 

NC

14

DRAIN

CAM 2

 

2

 

 

NC

M

 

 

 

 

 

 

 

15

 

 

15

BLK

MAIN

 

 

 

 

 

 

3

 

 

 

NO

 

 

2

WHT

 

 

 

19

F V

 

TP

 

 

CAM 5

 

 

4

8NC

2

2

20

NO

CAM 4

8NC

16

NO

(IF USED)

5

GRN

 

 

DP

2

 

 

 

20 D V

2

GND

 

GND

 

2

 

PSDR 16

34

21

CAM 7

8NC

DM

2

17

17

NO

(IF USED)

22

CAM 6

8NC

RM

2

1

 

DSS

 

1

50

2

 

 

1CR

BLK

BLACK

CLT

CYCLE ON LIGHT

 

PSS

PRIME SWITCH SANITIZER

BLU

BLUE

DM

DETERGENT MOTOR

ICR

RELAY

 

CAM 1

HOMING

DP

DRAIN PUMP

(IF USED)

DSS

REED SWITCH

 

CAM 2

PUMP MOTOR

RL

RELAY

 

RM

RINSE MOTOR

(IF USED)

CAM 3

PUMP MOTOR REVERSING

DV

DRAIN VALVE

 

SRC

CURRENT OPERATED START RELAY COIL

CAM 4

DRAIN

FV

FILL VALVE

 

SM

SANITIZER MOTOR

 

CAM 5

FILL

GND

GROUND

 

TM

TIMER MOTOR

 

CAM 6

RINSE

GRN

GREEN

 

TP

THERMAL PROTECTOR

 

CAM 7

DETERGENT

HTLS

HIGH LIMIT THERMOSTAT

WHT

WHITE

 

CAM 8

CYCLE

MSW

MAIN SWITCH ON/FILL OFF/DRAIN

WHTR

WATER HEATER

 

 

 

PSDR

PRIME SWITCH DETERGENT, RINSE

WTS

WATER THERMOSTAT

A

 

RELEASED TO

SKH

AUG

 

PRODUCTION

 

01/03

REV

ECN

DESCRIPTION

BY

DATE

CH

 

 

 

 

TOLERANCE

 

HOLE DIMENSIONS

ISSUED

SCHEMATIC 401+ SERIES HTN

DECIMAL

A

 

F

 

 

ANGLE

B

 

G

 

DR.

 

 

SCALE 1:1

C

 

 

 

DRAWING NO.

 

 

 

CH.

 

 

 

 

 

 

FORMING:DIMENSIONS ARE FROM

E

 

J

 

RTG.

 

0510653

BRAKELINE TO BRAKELINE

D

 

H

 

 

 

UNLESS OTHERWISE NOTED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 13 — Electrical Diagram, 401-HTN PLUS

41

Image 47
Contents Technical Manual Copyright 2003 by Moyer Diebel Revision History This Intentionally Left Blank Contents Detergent Pump Assembly Introduction Limited Warranty Standard equipment includes GeneralL1L2N G Electrical Connections InstallationUnpacking Chemical Sanitizer Plumbing ConnectionsDetergent/Chemicals Rinse AidCompleting Installation Operation Summary Daily Operation ProceduresOperation Operation Cleaning Schedule MaintenanceAs Required Maintenance ScheduleDeliming Deliming ProcedureCondition Cause Solution TroubleshootingThis Intentionally Left Blank Replacement Parts Track and Panel Assembly Part Door and Switch Assembly 0501412 Screw, 10-32 x 3/8 Truss Head 0308596 Tank/Drain Assembly 0508628 Pump Assembly 0502704 Wash System Assembly 0508549 Booster Assembly and Water Inlet Piping HT Plus Only Booster Assembly and Water Inlet Piping HT Plus only Water Inlet Piping HTN PLUS, LT Plus Only 0503718 Fill System 107417 Hose, 1/2 I.D. HTN PLUS, LT Plus 0501518 Rinse Aid DETERGENT/RINSE AID Pump Assembies HT PLUS, HTN Plus Detergent/Sanitizer/Rinse-Aid Pump Assembly LT Plus Only DETERGENT/SANITIZER/RINSE-AID Pump Assemblies LT Plus only Control Panel Assembly 0501379 This Intentionally Left Blank Electrical Schematics 0510652 0510653 0510654 Timer Assembly 401-HTM2 Timer Assembly 401-LTM2