Varimixer 40, W100, MK IV, W80, 60 manual Error Codes, Hot

Page 12

Error Codes

A error in the mixer will trigger an ERROR code in the time display. See the chart below for an explanation of error codes and the procedure for correcting them.

E:401 E:301 E:201

HOT

E:201 The servo motor block actuator (B) did not contact the minimum speed microswitch (A) after the stop button was pushed or the programmed recipe completed.

The computer is programmed to slow the mixer down to low speed before shutting off. It will not do this unless the microswitch is contacted by the block mounted on the speed adjustment shaft.

To correct this error:

1)Check the microswitch (A) to see if it is working by manually pushing it, when pushed, the “MIN” light should energize on the control panel. If it does not, the microswitch is faulty.

2)The actuator (B) is not contacting the switch, adjust the switch up by loosening the screws (C).

3)The servo motor is not moving at all. check the fuses in the rear of the control , if blown, replace ,if not blown ,check the voltage (31 VDC) at the servo motor while the mixer is running. If voltage is present, the servo is faulty.

 

Min

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Max

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

10

Image 12
Contents MK-IV Page Modes Function Explanation CLR Step Hold for 3 Seconds Page Hold for 3 Seconds RPM Mode Speed ModePage Error Codes HOTAmp W40 375 Speeds RPM W60 390 W80 422 W100 Maintenance and Adjustments Page Page Lubrication Leave Against ARM Belt Exchange Belt Exchange Adjustment of low and high speed microswitches Adjustment of low and high speed microswitches Measure I.D. of hole Speed Servo System Power Supply Power Supply Page Page Power Supply Wiring Diagram Page Campus Drive Shreveport LA 800 318 635-3131 Fax