Varimixer Porter Cable PTX5 Mixer Troubleshooting Guide for Speed Pickup and Overload Issues

Page 13

E:301 There is no signal from the speed pickup (hall effect sensor).

To correct this error:

1)Check that the sensor (D) is centered directly above the track of the 3 magnets (F) on the pulley and the gap between the sensor and magnets is 1/16”. If not , bend and / or move the bracket (I) holding the sensor.

2)Inspect the three wires between the sensor and the plug. Replace the sensor if wires are broken.

3)Insure the aluminum disc (E) is tight on the pulley.

Side View

 

Top View

DE

F

I

E

D

HOT The thermal overload has tripped because of excessive amp draw or heat.

The overload will automatically reset after it has cooled. This function is to protect the mixer.

To correct this error:

1)Have a service technician inspect all wiring, contactor and overload for faults.

2)Monitor the amp draw while the unit is operating. If excessive, the drive motor may be failing.

1.5 Amp

11

Image 13
Contents MK-IV Page Modes Function Explanation CLR Step Hold for 3 Seconds Page Hold for 3 Seconds Speed Mode RPM ModePage HOT Error CodesAmp W40 375 Speeds RPM W60 390 W80 422 W100 Maintenance and Adjustments Page Page Lubrication Leave Against ARM Belt Exchange Belt Exchange Adjustment of low and high speed microswitches Adjustment of low and high speed microswitches Measure I.D. of hole Speed Servo System Power Supply Power Supply Page Page Power Supply Wiring Diagram Page Campus Drive Shreveport LA 800 318 635-3131 Fax