2Wire AU5400, AU2700 specifications Online parameters list

Page 46

(2) Online parameters list

Transmission information

Contents

 

menu

T.R.I. receive

 

 

 

 

Normal sample

Real-time/batch/none

[PARAMETER] [ONLINE] [SETUP]

 

Emergency sample

Real-time/batch/none

menu.

 

Stat sample

Real-time/batch/none

 

 

 

Normal Repeat sample

Real-time/batch/none

 

 

 

Emergency Repeat sample

Real-time/batch/none

 

 

 

Stat Repeat sample

Real-time/batch/none

 

 

Test result transfer

 

 

 

 

Normal sample

Real-time/batch/none

 

 

 

Emergency sample

Real-time/batch/none

 

 

 

Stat sample

Real-time/batch/none

 

 

 

Stat Fast sample

Real-time/none

 

 

 

Normal Repeat sample

Real-time/batch/none

 

 

 

Emergency Repeat sample

Real-time/batch/none

 

 

 

Stat Repeat sample

Real-time/batch/none

 

 

 

QC sample

Real-time/batch/none

 

 

 

Calibration sample

Real-time/batch/none

 

 

 

Reagent blank sample

Real-time/batch/none

 

 

Protocol 2

Contents

 

menu

Error control

 

 

 

 

Receive

Continue/stop

[PARAMETER] [ONLINE]

 

Transfer

Continue/stop

[PROTOCOL] menu.

Protocol –1

Contents

 

menu

Data format

 

 

 

 

character length

7/8

 

[PARAMETER] [ONLINE]

 

parity bit

ODD/EVEN/none

 

[PROTOCOL] menu.

 

stop bit

1/2

 

 

 

 

 

 

 

Basic text format

 

 

 

 

start code 1

00H-FFH

 

[PARAMETER] [ONLINE]

 

start code 2

00H-FFH

 

[PROTOCOL] menu.

 

end code 1

00H-FFH

 

 

 

end code 2

00H-FFH

 

 

 

Max text length

256/512/1024

 

 

 

unit no.

00-99 space

 

 

 

use ETB

use/none

 

 

 

 

 

 

 

Sequence control

 

 

 

 

bit/sec

4800/9600

 

 

 

protocol

class A/class B

 

 

 

BCC check

use/none

 

 

 

retry times

(0-3)

 

 

 

time out T1

nn

 

 

 

T2

nn

 

 

 

T3

nn

 

 

 

T4

nn

 

 

 

T5

nn

 

 

 

T6

nn

 

 

 

T7

nn

 

 

Text Format

- 46 -

Image 46
Contents ON-LINE Specifications AU2700/5400 Online Specifications Issued RevisedPage Outline Format of Transmission Transmission codeText format OptionalOnline Protocol menu Page Common and changeable item T.R.I. inquiry textPage T.R.I. text Test result transmission text Page Page Page Page Page Page Assigned area is decided associated with the rack No Page Relation between real-time/batch and Transmission text Others RequisitionParameteronline Special menu Page LIP ICT HEM Normal LIP ICT HEM Normal Flag Page Parameter Common Test Parameters Round Transmission Protocols Protocols at AU2700/5400ACK ACK NAK NAK Timing/time-out Case AU2700/5400 Host T2T1 Rule of class B Page Application Protocol Receiving T.R.IThis text is transmitted at the designated time intervals Page Sending test result protocol DB StartPage Others Signal Level In/Output signals and TerminalsApplicable Connector Appendix Flags list To any reason Online parameters list Parameter Format Page Character Table AU2700/5400 Online Parameter Sheet AGE/MONTH Online Alarm List Page Page Page RH U Page Page Page Page Page Page Page