Keating Of Chicago 2009 manual Troubleshooting Chart

Page 13

TROUBLESHOOTING CHART

The following diagnosis is only to be used as a guide to qualified service personnel. Keating recommends that you use a qualified service company. Call 1-800-KEATING if you need assistance in locating a qualified service company.

COMMON PROBLEMS

SOLUTIONS (FOLLOW IN SEQUENCE)

 

 

Water always filling

1. Clean sensors thoroughly with brush and vinegar.

 

2.

Adjust the sensitivity of the B Board (for the top sensor) fully clockwise.

 

3.

If filling persists, ground out the top sensor (if filling stops, replace sensor –

 

 

Part #010212).

 

4.

If filling persists after grounding the sensor, replace the B Board (Part

 

 

#001166).

 

 

 

Water never fills

1.

Turn water switch (far right) ‘on.’

 

2.

Clean sensors thoroughly with the brush and vinegar.

 

3.

Adjust the sensitivity of the B Board (for the top sensor) fully counter

 

 

clockwise (follow sevice instruction sheet - Setting Water Level Control).

 

4.

Remove the wire from the top sensor. If filling begins, replace sensor (Part #

 

 

010212).

 

5.

If water does not fill, place a jumper wire across terminals A & C on the B

 

 

Board. If filling begins, replace B Board (Part # 001166).

 

6.

If water does not fill, replace water solenoid (Part # 008133).

 

 

Timers counting down in the

1. Reset the timer (see pages 8-9).

wrong mode (not minutes or

 

 

seconds)

 

 

 

 

 

Water leaking in the rear of

1.

Replace fill hose (Part #037390 – sold per foot)

the pasta cooker

 

 

 

 

 

Breakers continue to trip

1.

Ensure all wires to the contactors, breakers and elements are tight.

 

2.

Verify water is not getting on any components.

 

3.

Check contactors for proper operation.

 

4.

Check continuity of heating elements.

 

5.

Replace breaker.

 

 

 

Heating elements won’t

1.

Verify operating instructions in the manual.

come on

2.

Clean sensors with brush and vinegar.

 

 

3.

Adjust sensitivity of the A Board (for the lower sensor) fully clockwise (follow

 

 

service instruction sheet - Setting Water Level Control).

 

4.

Place the wire attached to the lower sensor to the ground (if heating begins,

 

 

replace sensor – Part #010212).

 

5.

If heating does not being, place a jumper wire across terminals A&C on the A

 

 

Board. If heating begins, replace the A Board (Part #001167).

 

 

 

11

Image 13
Contents Custom Pasta System Electric Series Post this Label in a Prominent Location on Your Unit Introduction Safety Precautions If Equipment Arrives Damaged II InstallationConcealed Loss or Damage Visible Loss or DamageRestraining Devices PositioningLeveling Electrical ConnectionIII Operation Draining CleaningDigital Timers Timer Operating InstructionsHOW to Program the Keating Electronic TimerWarranty Repairs IV MaintenancePreventive Maintenance Limited CalibrationThermostat Calibration 2000 Model Cooker Heating Section Service DiagnosisTroubleshooting Chart Problem Probable Cause Solution Custom Pasta System Electric Control Panel Assembly VI Parts ListOrdering Parts Description Models Parts List for Custom Pasta SystemElectric Pasta 2-THERMOSTAT Wiring Diagram Without Timers VII Wiring DiagramsElectric Pasta with Digital Timers Wiring Diagram Page Page Page Electric Pasta 2-THERMOSTAT Wiring Diagram Without Timers Electric Pasta with Digital Timers Wiring Diagram Page Serving Those Who Serve The Very Best