PREPARE THE HOOD
1. Lay the hood on its back on a table. |
Remove grease filters by lifting the metal latch tab (1), |
pushing down on the filter (2) and tilting is towards you (3). |
NOTE |
Use a piece of cardboard to avoid damaging the table or the |
hood. |
3 |
1 |
2 |
HD0376 |
2.Choose the opening:
VERTICAL DISCHARGE:
Using a Robertson or a Phillips no. 2 screwdriver, remove the 4 top metal plate retaining screws in order to clear the vertical discharge opening (see illustration beside). Discard the metal plate and its screws.
RETAINING SCREWS LOCATIONS |
HO0142 |
Warranty
Safety
Operation
HORIZONTAL DISCHARGE:
In order to ease a retrofit installation, the horizontal discharge may be positioned on higher OR on lower back of the hood. From outside the unit, remove the knockout for the chosen discharge opening (see illustrations beside).
1 | 2 |
OR | OR |
HR0038 |
|
Cleaning
Installation
Service Parts