Precision Power manual DCX 300.2, DCX 500.2 Front Plate Diagram

Page 14

DCX 300.2, DCX 500.2 FRONT PLATE DIAGRAM

1211

DC X 300.2 DCX 500.2

FrontPanel

 

 

R

 

 

 

 

 

R

 

 

BR ID G E

 

 

 

 

 

 

 

 

 

 

-

+

 

O UTPUT XOVER

 

 

G AIN

 

 

XOVER

 

 

 

 

 

FREQ Q BASS

ATT

 

 

 

 

 

 

 

LP

 

 

 

 

 

LP

 

 

L

30

40k

 

 

M IN M AX

L

30

40k

R- R+ REM L+

L-

 

O UTPUT FREQ FULL HP

2

1

-12dB

 

INTPUT FREQ FULL HP

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

10

1.Cooling Plenums: Maintain a minimum 2” clearance around cooling plenums for proper amplifier cooling.

2.Speaker/Remote Connector: Plug in the PowerLockTM connector here.

3.Output Xover Freq. Control: Use this control to adjust the sub bass output signal crossover frequency from 30Hz to 4kHz. (See the Crossover Frequency chart in this manual).

4.Output Xover FULL/LP/HP Switch: Select the desired crossover setting HP/LP/FULL for the signal of the RCA outputs.

5.QBASSTMFreq.: Use this adjustment to set the QBASSTM frequency.

6.-12dB Input Attenuation: Push this switch ‘IN’ for high voltage (4V-12V) capability. This button pushed ‘IN’ must be used for speaker level input on common ground head-units or for high voltage line drivers.

7.Gain: Use this control to match the output level of the source unit to the amplifier.

8.Input: Plug in the RCA leads from your source here.

9.Xover Adjustment: Adjusts the crossover between 30Hz and 4kHz.

10.Xover FULL/LP/HP Switch: Select the desired crossover setting FULL/LP/HP.

11.QBass: Adjusts the amount of boost provided by the QBASSTM circuit.

12.RCA Outputs: RCA outputs provide HP/LP/FULL 30-4kHz signal to another amplifier.

13

Image 14
Contents Amplifier Models Table of Contents Service CongratulationsFeatures Qbass Plus SpecificationsSpecifications Power Ratings35 a Amplifier Status Leds TOOLS/PARTS for Installation WiringPage Ground Wiring Charging SystemCurrent Draw Power Wire Size Powerlock Connectors DCX 300.2, DCX 500.2 Front Plate Diagram DCX 300.2, DCX 500.2 END Plate Diagram Inputs Advanced Instrumentation InputQbass PLUS/QBASS Remote DCX 300.2/500.2 TC-X CrossoverCrossover Detent Chart AP-IV Protection Circuit Adjusting Input GainHigh Mass Internal Heatsink Opposite Channel Same Channel Limited TWO Year Consumer Warranty