UNIT/MAINTENANCE SAFETY

Turn off all controls and allow the mo- tor to stop before disconnecting the unit from the power source.

Disconnect the unit from the power source when not in use. Do not leave

the unit when it is plugged into outlet.

Do not set the unit on any surface ex- cept a clean, hard area while the unit is running. Debris such as gravel, sand, dust, grass, etc., could be picked up by the air intake and thrown out through the discharge opening, damaging the unit, property, or caus-

ing serious injury to bystanders or op- erator.

Do not overreach or use from unstable surfaces such as ladders, trees, steep slopes, rooftops, etc. Use extra care when cleaning on stairways. Keep firm footing and balance at all times. Keep hands out of tubes.

Inspect the entire unit before each use for worn, loose, missing, or damaged parts. Do not use until the unit is in proper working order.

Disconnect unit from power source be- fore servicing, cleaning, performing maintenance, or storing.

This unit is double insulated. See the DOUBLE INSULATION section. Have all

internal service performed by qualified service repair personnel to avoid creating a hazard or voiding your war- ranty.

Have all maintenance other than the

recommended procedures described in the instruction manual performed by your Sears Service Center.

Always see your Sears Service Cen- ter to replace a damaged impeller. Parts that are chipped, cracked, bro- ken, or damaged in any other way can fly apart and cause serious inju- ry. Replace damaged parts before using the unit.

Never place any object in the air in- take opening as this could restrict

proper air flow and cause damage to the unit.

Never douse the unit with water or

other liquids or squirt with a water hose. Clean with a damp sponge and mild soap. See STORAGE.

Check air intake openings and tubes frequently, always with the unit stopped and power source discon-

nected. Keep vents and tubes free of debris which can accumulate and re-

strict proper air flow.

Do not burn, incinerate, or expose this unit to extreme heat.

Store the unit unplugged in a high,

cool, dry, indoor area out of the reach of children.

Use only recommended attachments and replacement parts to avoid creat- ing a hazard and/or voiding warranty.

Maintain the unit according to recom- mended procedures.

Use only for jobs explained in the OP- ERATION section of this manual.

BLOWER SAFETY

Use only in daylight or in good artificial light.

Inspect the area before using the unit. Remove all debris and hard ob-

jects such as rocks, glass, wire, etc., that can ricochet, be thrown, or oth- erwise cause injury or damage dur- ing operation.

Avoid accidental starting. Be sure the switch is in the OFF position and keep your hand and fingers away from the switch while connecting the unit to the power source or when carrying a unit connected to the power source.

Never run the unit without the proper equipment attached. When used as a blower, always install a blower tube. Use only recommended attachments. Do not use with any opening blocked, Keep free of dust, lint, hair and any- thing that may reduce air flow.

To avoid spreading fire, do not use blower near leaf or brush fires, fire-

places, barbecue pits, ashtrays, etc.

Never place objects inside the blower tubes; always direct the blowing debris away from people, animals, glass, and solid objects such as trees, automo- biles, walls, etc. The force of air can

cause rocks, dirt, or sticks to be thrown or to ricochet which can hurt

people or animals, break glass, or cause other damage.

Never use for spreading chemicals, fertilizers, or any other substances which may contain toxic materials.

VACUUM SAFETY

Stop the motor and disconnect the power source before opening the air

inlet door or attempting to insert or re- move the vacuum tubes. The motor

must be stopped and the impeller blades no longer turning to avoid seri- ous injury from the rotating blades.

Hard objects can be thrown through the collection bag or the housing and become dangerous missiles which

can cause serious injury to the opera- tor or others.

4

Image 4
Contents CRRFTgMRNI AMP Motor 195 MPH/405 CFMFull ONE Year Warranty on Sears Craftsman Electric Blower Operator SafetyAN Extension Cord Electrical SafetyDouble Insulation Construction Blower Safety UNIT/MAINTENANCE SafetyVacuum Safety Carton Contents Blower AssemblyVacuum Assembly Uumwaterorotherliquids. mulateandrestrictproperairflowDoUmuse WithyourotherhandLatchArea ImpellerAdjustthestraptoallowfreeflow SupporttheweightoftheunitTionbagiskinked,theunitwillnot OperateproperlyKnowyourelectric Blower Using Your Unit AS a BlowerOperating Position Customer Responsibilities Care & Maintenance Task Using Your Unit AS a VacuumInspect and Clean Unit & Labels HOW to Remove AN Object from the AIR Intake Troubleshooting TableBlower Storage PartsNo EN LOS Estados Unidos Seguridad DEL UsuarioSeguridad Electrica AdvertenciaExtension Construccion DE Doble Aisla MientoSeguridad DEL Aparato Y SU Mantenimiento Seguridad DE LA Aspiradora Seguridad DE LA Propulsor DE AireCriterios PULSION/BOQUILLA Contenido DE LA CajaMontaje DEL Aspiradora Limitador Aspiraci6n Como Convertir EL Aparato DE USO DE Aspiracion a USO DE PropulsionInstalacion DE LOS Tubos DE Elija UN Cable DE ExtensionConozca SU Propulsor DE Aire Electrica Cuchillas DesmenuzadorasCerrojo DE LA Compuerta DE Aspiraction Detener SU AparatoAirepara Patios,etcLimpielabolsa DE Coleccion Remover Objetos DE LA Toma DE AireAlmacenaje DE LA Propulsor DE Aire Piezas DisponiblesTabla Diagnostica OFE