Symmetricom 5401, 5402 manual Operating Manual Contents, PN 8500-0150, Rev. A, May Contents-1

Page 7

Operating Manual

Contents

Preface

Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii Limitation of Liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv

Proprietary Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv

Where to Find Answers to Product and Document Questions . . . . . . . . . . . . . iv Warnings, Cautions, Recommendations, and Notes . . . . . . . . . . . . . . . . . . . . iv

Conventions Used in This Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v

1 — Introduction

Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

Symmetricom 5401 Airborne Disciplined Rubidium Oscillator . . . . . . . . . .2

Symmetricom 5402 Disciplined Rubidium Oscillator . . . . . . . . . . . . . . . . .2

2 —Installation

Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Unpacking and Inspection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Symmetricom 5401 Installation Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Symmetricom 5401 Initial Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Symmetricom 5401 Adjustments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Symmetricom 5402 Rack Mounting Procedure. . . . . . . . . . . . . . . . . . . . . . . . . .5

Symmetricom 5402 Installation Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

Symmetricom 5402 Initial Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

Symmetricom 5402 Adjustments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

3 —Operation

RS-232 Input/Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

Status Request . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

Discipline Off. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

Discipline On. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

Dynamic Gain Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

Enter KM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

Enter KO1, KO2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

Enter Disgain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

Enter Resync Threshold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

Enter Resync Delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13

Enter Rate Threshold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13

PN 8500-0150, Rev. A, May 2005

Contents-1

Image 7
Contents Airborne Disciplined Rubidium Oscillator Symmetricom, Inc Operating Manual Preface Limited WarrantyLimitation of Liability Where to Find Answers to Product and Document QuestionsProprietary Notice Conventions Used in This Guide Operating Manual Preface Typographical Conventions When text appears It means This wayPN 8500-0150, Rev. A, May Contents-1 Operating Manual ContentsOperating Manual SpecificationsOperating Manual Introduction Product OverviewSymmetricom 5402 Disciplined Rubidium Oscillator Symmetricom 5401 Airborne Disciplined Rubidium OscillatorUnpacking and Inspection InstallationSymmetricom 5401 Installation Procedure Operating Manual Installation5401 Adjustment Locations Symmetricom 5401 AdjustmentsSymmetricom 5402 Rack Mounting Procedure Symmetricom 5402 Adjustments Symmetricom 5402 Installation ProcedureSymmetricom 5402 Initial Operation Operating Manual Operation RS-232 Input/OutputStatus Request Operating Manual Operation DRO Commands Via RS-232Description Discipline OffDynamic Gain Control Discipline OnEnter KO1, KO2 Enter KMMinutes Enter Resync Threshold Enter DisgainEnter Rate Threshold Enter Resync DelayTurns burst status off Burst Status OnBurst Status Off Status will be output every secondRequest TI DRO Discipline Sequence FlowchartRequest Firmware Version Enter DAC ValueDTyyy Firmware Number PN 8500-0150, Rev. A, May Request Start-up Parameters Enter Start-up ParametersOperating Manual Operation Revision Letter of Firmware Response Format Description Calibrate UnitReturns the unit to a default state Default Values Set DefaultsEnter 1 PPS Offset not implemented Request Setup ParametersInput Threshold High/Low Enter Oscillator Control Range not implemented Enter Programmable Delay ValueDesign Verify On/Off Enter Estimation Filter Time Constant Cal StatusEnter Dynamic Gain Factors Operating Manual Specifications Input Specifications and CharacteristicsInput Specifications and Characteristics Output Specifications and Characteristics Output Specifications and CharacteristicsCoherence a DRO Internal Time Bases Indicators Front Panel5401 Indicators Front Panel 5402 Indicators Front PanelMHz Oven Oscillator Operating Manual Specifications DRO Internal Time Bases10 MHz Oven Oscillator Approximately 10 pounds PN 8500-0150, Rev. A, May DimensionsWeight Approximately 8 poundsEMI Environment

5401, 5402 specifications

The Symmetricom 5402 and 5401 are highly regarded timing and synchronization solutions designed for telecommunications and data networking applications. These devices are part of the renowned line of precision timekeeping products developed by Symmetricom, which is now known as Microchip Technology.

The Symmetricom 5402 offers advanced capabilities, including GPS and precision time protocol (PTP) synchronization. It provides an accurate and stable time reference, crucial for industries that require precise timing to ensure system integrity and communication efficiency. The 5402 supports various synchronization protocols including IEEE 1588v2, ensuring interoperability with existing systems. This allows organizations to implement cutting-edge technologies while maintaining compatibility with older infrastructure.

On the other hand, the Symmetricom 5401 serves as a more compact and economical option tailored for specific applications where full GPS capabilities may not be necessary. This unit simplifies the synchronization process while still offering reliable performance. The 5401 provides multiple outputs including T1/E1 and 10 MHz, making it versatile for different network configurations.

Both models incorporate advanced oscillator technology that ensures accuracy and stability. They have a temperature-compensated crystal oscillator (TCXO) or optional oven-controlled crystal oscillator (OCXO) that provides superior frequency stability across a wide range of operating conditions. These devices also feature high-performance phase-locked loops (PLLs), which enhance their ability to maintain synchronization over time and under varying operational environments.

Additional features include robust network management capabilities, allowing for real-time monitoring and diagnostics through a user-friendly interface. The devices are equipped with multiple input/output ports that facilitate seamless integration into existing network architectures. The Symmetricom 5402 and 5401 support both local and remote management, enabling network administrators to maintain optimal synchronization performance.

In summary, the Symmetricom 5402 and 5401 deliver reliable, high-precision timing solutions designed to meet the demands of modern telecommunications infrastructures. With their advanced synchronization technologies, versatile connectivity options, and robust performance characteristics, these devices are essential components for ensuring accurate timekeeping in any network. Whether organizations choose the feature-rich 5402 or the cost-effective 5401, they can be confident in the reliability and precision these products deliver.