Xantrex Technology 975-0057-01-01 warranty Troubleshooting Reference, 1Troubleshooting reference

Page 56

Troubleshooting

Troubleshooting Reference

WARNING: Electric shock hazard

Do not remove the cover of the XPower Powerpack or disassemble the XPower Powerpack except to replace the internal battery or 250 A fuse. The XPower Powerpack does not contain any internal user-serviceable parts and attempting to service the unit yourself could result in electrical shock or burn.

Table 5-1Troubleshooting reference

ACProblemPossibleappliance AC applianceCauseSolutionrated Use an AC appliance with a power

will not

more than 320 W, the

rating less than 320 W.

operate;

safety overload has

 

audible alarm

tripped.

 

is not

 

 

sounding.

AC appliance is rated

AC appliance may exceed the

 

less than 320 W, high

XPower Powerpack’s surge

 

starting surge has

capability. Use an AC appliance with

 

tripped the safety

a starting surge within the XPower

 

overload.

Powerpack surge rating.

 

 

 

AC appliance

Battery has discharged

Turn the AC Outlet On/Off switch

will not

to 10.5 V.

off and recharge the XPower

operate;

 

Powerpack.

audible alarm

 

 

is sounding.

Inverter has

Turn the AC Outlet On/Off switch

 

overheated due to poor

off and allow the XPower

 

ventilation or

Powerpack to cool for 15 minutes or

 

excessively warm

more. Clear blocked fan opening or

 

environmental

remove objects covering the unit,

 

conditions.

then restart the XPower Powerpack.

 

 

Move to a cooler environment.

5-2

975-0057-01-01

Image 56
Contents Fax 1 Page Purpose Conventions UsedReferences to XPower Powerpack Related InformationImportant Safety Instructions Important Safety Instructions Plus Precautions When Working With Batteries 975-0057-01-01 Vii Precautions for Using Rechargeable Appliances Contents Maintenance Troubleshooting SpecificationsXii Introduction Comprehensive ProtectionAutomatic overload OverheatingLow Battery Protection Jump-Start Cables Safety FeatureFeatures Materials ListXPower Powerpack Features Front Panel DetailInverter’sConditionRequiredON/OFF Condition Air Compressor XPower Powerpack 400 Plus only Light On/Off Switch Left Side ViewFeature Accessories Accessory bagOperation Operating Conditions and GuidelinesCool Choosing a LocationRecharging with the AC Charger To recharge with the AC ChargerUsing the light Operating AC Appliances Understanding AC AppliancesHigh Surge Appliances Operating an AC Appliance To operate an AC applianceOperating 12 V DC Appliances Appliance To operate 12 V DC applianceJump-Starting a Vehicle’s Engine To jump-start a vehicle or boat engine Using the Air Compressor XPower Powerpack 400 PlusOver-Temperature Safety Protection Inflating TiresTo inflate your vehicle, motorcycle, or bicycle tires Inflating Small Sports Equipment To inflate small sports equipmentConnecting to an External Battery Connecting to an External Battery Page Maintenance Battery MaintenanceRecharging with the AC Charger Function buttonRecharging with the DC Charging Cable 975-0057-01-01 975-0057-01-01 Recharging with a Generator’s Regulated 12 V DC Outlet Replacing the Internal Battery Battery LifeRecharging From a Solar Panel To recharge with a solar panelPanasonicReplacementBatteryWhere PanasonictoBuy Obtaining a Replacement BatteryReplacing the Battery To replace the battery975-0057-01-01 Recycling Replacing the Incandescent LightReplacing the External Fuse Troubleshooting Common ProblemsBuzz in Audio Equipment Television InterferenceTroubleshooting Reference 1Troubleshooting referenceSolution Charging ProblemPossibleCause ProblemPossibleCauseSolution Specifications Electrical SpecificationsOutputACPowerpowerSection DepthPhysicalspecifications Page Warranty and Return WarrantyExclusions DisclaimerProduct Return Material Authorization Policy Return ProcedureOut of Warranty Service Information About Your System