McIntosh C2300 XLR Connectors, Power Control and Trigger Connectors, Data Port Connectors

Page 4
Data
Signal

General, Connector and Cable Information

General Information

Connector and Cable Information

1.The C2300 uses Vacuum Tubes for amplifying the audio signal. The C2300 is designed to have only quali- fied Service Personnel perform any part(s) replacement including all the vacuum tubes.

2.For additional connection information, refer to the owner’s manual(s) for any component(s) connected to the C2300 Tube Preamplifier.

3.The Main AC Power going to the C2300 and any other McIntosh Component(s) should not be applied until all the system components are connected together. Failure to do so could result in malfunctioning of some or all of the system’s normal operations. When the C2300 and other McIntosh Components are in their Standby Power Off Mode, the Microprocessor’s Circuitry inside each component is active and communication is occurring between them.

4.Up to two Sensors can be wired in parallel for Remote Control of the C2300 from other rooms.

5.Balanced and Unbalanced Inputs and Outputs can be mixed. For example, you may connect signal sources to Unbalanced Inputs and send signals from the Balanced Outputs. You can also use Balanced and Unbalanced Outputs simultaneously, connected to different Power Amplifiers.

XLR Connectors

Below is the Pin configuration for the XLR Balanced Input

and Output Connectors on the C2300. Refer to the dia-

grams for connections:

 

 

PIN 1: Shield/Ground

 

 

PIN 2: + Output

 

 

PIN 3: - Output

 

 

PIN 2

PIN 1 PIN 1

PIN 2

PIN 3

PIN 3

 

Power Control and Trigger Connectors

 

The C2300 Power Control and

Main Output Jack

Trigger Output Jacks send Power

Power

 

On/Off Signals when connected to

 

Control

 

McIntosh and other Components. An

 

Meter

 

additional connection on the Main

Illumination

 

Power Control Jack is for controlling

Control Ground

 

the illumination of the Power Output

Output 1 and 2, ACC

Meters on McIntosh Power Ampli-

Jacks

 

fiers. A 1/8 inch stereo mini phone

 

 

plug is used for connection to the

Power

 

Power Control and Trigger Outputs

Control

 

N/C

 

on the C2300.

 

 

 

Note: The Data, Power Control and

Ground

 

 

 

Trigger Connecting Cable is

 

 

available from the McIntosh

Trigger

 

Parts Department:

Control

 

Data, Power Control and Trig-

N/C

 

ger Cable Part No. 170-202

 

 

Six foot, shielded 2 conductor,

Ground

 

with 1/8 inch stereo mini phone plugs on each end.

Data Port Connectors

The C2300 Data Out Ports send Remote Control Signals to McIntosh Source Components. A 1/8 inch stereo mini phone plug is used for connection.

N/C

Data

Ground

4

Image 4
Contents Tube Preamplifier Important Safety Instructions Customer Service Table of ContentsThank You Please Take a MomentPower Control and Trigger Connectors XLR ConnectorsData Port Connectors Introduction and C2300 Features C2300 FeaturesDimensions Installation Rear Panel Connections How to Connect the C2300 Trim Select Trim Adjust Front Panel Displays, Controls, Push-buttons and JackSetup How to Operate the Setup Modes Default SettingsTrim Level Adjustment Firmware VersionRe-Title Inputs Input Source SettingsMeter Illumination On/Off Setup, con’t Display Brightness Power Control TriggersAccessory Power Control Tube LEDRemote Control Push-Buttons How to use the Remote Control How to Operate the C2300 Power OnVolume Control Source SelectionBass How to Operate the C2300, con’t Tone BypassMono Record MonitorHeadphones Jack How To Make a RecordingReset of Microprocessors Output 1Silent Audio Switching Volume AdjustmentsTechnical Description Phono CircuitryPower Supply Circuits Meter and CircuitrySpecifications Packing Instructions McIntosh Laboratory, Inc Chambers Street Binghamton, NY