| Troubleshooting Guide |
| ||
|
|
|
|
|
|
|
| Pressure Washer Will Not Run - No Power |
| ||
| Causes |
|
| Solutions |
|
| Machine not plugged in |
|
| Plug machine in |
|
| GFCI tripped |
|
| Make sure machine is dry |
|
|
|
|
| Press RESET on the GFCI |
|
| Machine turned OFF |
|
| Turn Pump switch ON |
|
| Line circuit breaker tripped |
|
| Check for tripped circuit breaker in building |
|
|
|
|
| ||
|
| Circuit Breaker Trips During Operation |
| ||
| Causes |
|
| Solutions |
|
| Voltage too low |
|
| Check the voltage |
|
| Circuit Breaker Overloaded |
|
| Make sure to use NEMA specified receptacle |
|
|
|
|
| Make sure there is no other equipment using the same circuit |
|
|
|
|
| - see Specifications |
|
| Pressure set too high |
|
| Check/adjust pressure setting on unloader |
|
Pressure Washer Runs But No Pressure
Causes |
|
| Solutions |
Partially clogged or damaged nozzle |
|
| Clean or replace nozzle |
Low water flow |
|
| Make sure the water supply is more than the required flow |
| |||
Pressure Washer Surges Or Cycles While In Bypass | |||
Causes |
|
| Solutions |
Leak between pump and gun |
|
| Check all connections between pump and gun for leaks |
|
|
| Tighten loose components and replace damaged components |
Gun leaking internally |
|
| Replace spray gun |
|
| ||
| Smoke From Heat Exchanger | ||
Causes |
|
| Solutions |
Air band not adjusted properly | due to | Adjust the air band until the burner burns cleanly | |
different elevation |
|
| See Oil Burner under Installation Instructions |
Poor quality fuel |
|
| Use Kerosene for the cleanest burn |
|
| ||
| Water Not Heating Sufficiently | ||
Causes |
|
| Solutions |
Scale |
|
| See Coil Descaling under Maintenance Instructions |
Coil is full of soot |
|
| See Coil Desooting under Maintenance Instructions |
|
| ||
| Safety Relief Valve Sprays Water | ||
Causes |
|
| Solutions |
Unloader/Burner Control Problem |
|
| Call customer service |
|
| ||
| Poor Or No Detergent Supply | ||
Causes |
|
| Solutions |
Inadequate detergent supply |
|
| Refill detergent container |
|
|
| Make sure the chemical strainer is fully submerged |
High pressure hose too long |
|
| Use less hose |
|
|
| Move machine closer to the work |
Chemical strainer or injector clogged |
|
| Clean the strainer and injector. Always start with a clean detergent |
|
|
| container. Run clean water through the injector after each use. |
18