Marathon F200060 manual HEX DEC Block Parameter Description READ/WRITE, High BYTE, Analog Output

Page 18

HEX

DEC

BLOCK 0

PARAMETER DESCRIPTION

READ/WRITE

 

 

 

 

HIGH BYTE, ANALOG OUTPUT 2

 

 

 

 

 

 

BITS 8 – 12

 

 

 

 

 

 

0000

= N/A

 

 

 

 

 

 

0001

= Temperature

 

 

 

 

 

 

0010

= Linear Input A

 

 

 

 

 

 

0011

= Carbon value

 

 

 

 

 

 

0100

= Dewpoint value

 

 

 

 

 

 

0101

= Oxygen value

 

 

 

 

 

 

0110

= Redox value

 

 

 

 

 

 

0111

= Output Power

 

 

 

 

 

 

1000

= Control Output 1

 

 

 

 

 

 

1001

= Control Output 2

 

 

 

 

 

 

1010

= Linear Input B

 

 

 

 

 

 

1011

= Programmable*

 

 

 

 

 

 

*For Reference Number and Programmable ,

 

 

 

 

 

 

write required output value into DACV2, where

 

 

 

 

 

 

DACV2 = 0 is minimum output and

 

 

 

 

 

 

DACV2 = 4096 is maximum output.

 

 

 

 

 

 

BITS 13 – 15 SPARE

 

 

 

 

 

 

Special case: If Analog Output 1 = CONTROL

 

 

 

 

 

 

OUTPUT 1 and Analog Output 2 = CONTROL

 

 

 

 

 

 

OUTPUT 2 and the Control Mode is dual, then

 

 

 

 

 

 

Analog Output 1 is 4-20ma for 0 to +100% PO

 

 

 

 

 

 

and Analog Output 2 is 4-20ma for 0 to -100%

 

 

 

 

 

 

PO.

 

 

 

0C

12

 

DAC_OFFSET_1

DAC 1 OFFSET CALIBRATION

READ/WRITE

 

 

 

 

 

 

 

 

 

0D

13

 

DAC_SPAN_1

DAC 1 SPAN CALIBRATION

READ/WRITE

 

0E

14

 

DAC_OFFSET_2

DAC2 OFFSET CALIBRATION

READ/WRITE

 

 

 

 

 

 

 

 

 

 

 

0F

15

 

DAC_SPAN_2

DAC2 SPAN CALIBRATION

READ/WRITE

 

10

16

 

AOUTOF1

ANALOG OUTPUT 1 OFFSET

READ/WRITE

 

 

 

 

 

Minimum source value that correlates to

 

 

 

 

 

 

minimum Analog Output of 4 mA. The source

 

 

 

 

 

 

value is based on the selection in ASRC lower

 

 

 

 

 

 

byte

 

 

 

11

17

 

AOUTRN1

ANALOG OUTPUT 1 RANGE

READ/WRITE

 

 

 

 

 

Maximum source value that correlates to

 

 

 

 

 

 

maximum Analog Output of 20 mA. The

 

 

 

 

 

 

source value is based on the selection in

 

 

 

 

 

 

ASRC lower byte where

 

 

 

 

 

 

 

 

 

 

12

18

 

AOUTOF2

ANALOG OUTPUT 2 OFFSET

READ/WRITE

 

 

 

 

 

Minimum source value that correlates to

 

 

 

 

 

 

minimum Analog Output of 4 mA. The source

 

 

 

 

 

 

value is based on the selection in ASRC upper

 

 

 

 

 

 

byte

 

 

 

13

19

 

AOUTRN2

ANALOG OUTPUT 2 RANGE

READ/WRITE

 

 

 

 

 

Maximum source value that correlates to

 

 

 

 

 

 

maximum Analog Output of 20 mA. The

 

 

Page 15 of 23

11/14/2006

Rev. 14

Image 18
Contents Marathon Sensors Inc Oxymit Transmitter Operators ManualCopyright Marathon Sensors INC Table of Contents Typical Oxygen Transmitter Calibration F840030 Typical Carbon Transmitter CalibrationF840031 Block Diagram General DescriptionSafety Summary ConnectionsParameter Selections Grounding and ShieldingProcess Parameters Carbon Process Factor Parameter Name Selection Units or Options Range DefaultProcess Type Dew Point Process FactorOxygen Exponent TC TypeAnalog Output Channels Calibration Percent Carbon Process Variable CalculationsPercent Oxygen DewpointCommunications ModbusRTU Framing Function Field Error Check Field CRCAddress Field Data FieldCRC Memory Map LOW Byte Cold Junction Trim LOW Byte Input EventUpper Byte Load Line High Byte Host AddressBits 8 12 Redox Metal Number Bits 0 4 Oxygen ExponentBits 5 6 Display Decimal Place LOW BYTE, Analog OutputAOUTRN1 Analog Output 1 Range READ/WRITE HEX DEC Block Parameter Description READ/WRITEHigh BYTE, Analog Output AOUTOF2 Analog Output 2 Offset READ/WRITEBlock HEX DEC Parameter Description READ/WRITE Mvfil Temp Measured Temperature Read onlySpare READ/WRITE Tempfil Coldjct Cold Junction Read onlySpare Operational Specifications Percent oxygen 20.9% default800 3000 Address 1 is default Certifications and Compliance PendingImmunity as specified by EN Emissions as specified by EN

F200060 specifications

The Marathon F200060 is a high-performance electric skateboard that has rapidly gained recognition among both enthusiasts and casual riders alike. Combining cutting-edge technology with robust design, this skateboard is engineered to deliver an exhilarating riding experience.

One of the standout features of the Marathon F200060 is its powerful motor system. The skateboard is equipped with a dual-motor setup that offers impressive torque and acceleration, allowing riders to reach a top speed of up to 25 miles per hour. This feature makes it suitable for both commuting and leisurely rides, ensuring a thrilling experience on every journey. The motor system is also designed to be energy-efficient, offering extended battery life and reducing the need for frequent recharging.

Speaking of battery life, the Marathon F200060 boasts a high-capacity lithium-ion battery that can provide a range of up to 20 miles on a single charge. This feature is particularly beneficial for urban commuters, enabling them to travel long distances without the anxiety of running out of power. Additionally, the skateboard supports fast charging technology, allowing riders to recharge the battery in a matter of hours.

The construction of the F200060 is another aspect that sets it apart from its competitors. It features a sturdy, lightweight deck made from high-quality materials, providing both durability and stability. The skateboard's design includes high-grade wheels and advanced shock absorption systems that enhance ride comfort, making it effective for both smooth pavements and rough urban terrains.

In terms of safety, the Marathon F200060 is equipped with integrated LED lights that improve visibility during night rides. The skateboard also features advanced braking systems that allow for smooth and controlled stops, ensuring rider safety on all terrains.

Finally, the F200060 comes with smart technology integration, including Bluetooth connectivity that allows riders to connect their smartphones. Users can monitor battery life, customize settings, and even track their riding statistics through a dedicated app. This integration enhances the overall user experience and provides valuable data to help riders optimize their performance.

In summary, the Marathon F200060 electric skateboard embodies a blend of power, efficiency, safety, and smart technology, making it an excellent choice for anyone looking to elevate their ride. Its performance features and innovative design cater to the needs of modern riders, ensuring countless hours of enjoyment on the road.