Multiquip operation manual DCA-56SPX Maintenance

Page 39

DCA-56SPX — MAINTENANCE

TABLE 11. INSPECTION/MAINTENANCE

 

10 Hrs

250 Hrs

500 Hrs

 

1000 Hrs

 

DAILY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check Engine Fluid Levels

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Check Air Cleaner

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Check Battery Acid Level

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Check Fan Belt Condition

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Check for Leaks

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Check for Loosening of Parts

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace Engine Oil and Filter * 1

 

 

X

 

 

 

 

 

 

 

 

 

 

 

ENGINE

Clean Air Filter

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

Check Fuel Filter/Water Seperator Bowl

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Clean Unit, Inside and Outside

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

Change Fuel Filter

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

Clean Radiator and Check Coolant Protection Level*2

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

Replace Air Filter Element * 3

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

Check all Hoses and Clamps * 4

 

 

 

 

 

X

 

 

 

 

 

 

 

 

 

Clean Inside of Fuel Tank

 

 

 

 

 

X

 

 

 

 

 

 

 

 

GENERATOR

Measure Insulation Resistance Over 3M ohms

 

 

X

 

 

 

 

 

 

 

 

 

 

 

Check Rotor Rear Support Bearing

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*1

Replace engine oil anf filter at 100 hours, first time only.

 

 

 

 

 

*2

Add "Supplemental Coolant Addatives (SCA'S)" to recharge the engine coolant.

 

 

 

 

*3 Replace primary air filter element when restriction indicator shows a vaccum of 625 mm (25 in. H20).

 

 

*4

If blowby hose needs to be replaced, ensure that the slope of the bloby hose is at least a 1/2 inch per foot, with

 

 

no sags or dips that could collect moisture and/or oil.

 

 

 

 

 

General Inspection

Prior to each use, the generator should be cleaned and inspected for deficiencies. Check for loose, missing or damaged nuts, bolts or other fasteners. Also check for fuel, oil, and coolant leaks.Use Table 11 as a general maintenance guideline Engine Side (Refer to the Engine Instruction Manual)

Air Cleaner

Every 250 hours: Remove air cleaner element and clean the heavy duty paper element with light spray of compressed air. Replace the air cleaner as needed.

Air Cleaner with Dust Indicator

This indicator is attached to the air cleaner. When the air cleaner element is clogged, air intake restriction becomes greater and the dust indicator signal shows RED meaning the element needs changing or service. After changing the air element, press the dust indicator button to reset the indicator.

Service Daily

If the engine is operating in very dusty or dry grass conditions, a clogged air cleaner will result. This can lead to

aloss of power, excessive carbon buildup in the combustion chamber and high fuel consumption. Change air cleaner more frequently if these conditions exists.

Fuel Addition

Add diesel fuel (the grade may vary according to season and locations).

Removing Water from the Fuel Tank

After prolonged use, water and other impurities accumulate in the bottom of the tank. Occasionally inspect the fuel tank for water contamination and drain the contents if required.

During cold weather, the more empty volume inside the tank, the easier it is for water to condense. This can be reduced by keeping the tank full with diesel fuel.

DCA-56SPX— OPERATION AND PARTS MANUAL — REV. #1 (04/14/10) — PAGE 39

Image 39
Contents Model DCA-56SPX Parts List NO. B4871301604 S/N 3796699~Diesel engine exhaust and some Proposition 65WARNINGDCA-56SPX- Operation and Parts Manual REV. #1 04/14/10 Table of Contents Ordering parts has never been easier Parts Ordering ProceduresDCA-56SPX Specifications Dimensions DCA-56SPX Dimensions TOP, Side and FrontHazard Symbols DCA-56SPX Safety Message Alert SymbolsDCA-56SPX Safety Message Alert Symbols Carbon monoxide gas General SafetyDCA-56SPX Rules for Safe Operation Injury PeopleDCA-56SPX Rules for Safe Operation Maintenance SafetyDCA-56SPX Rules for Safe Operation Battery SafetyDeath Guidelines section in this manual Towing and Transporting SafetyDCA-56SPX- Operation and Parts Manual REV. #1 04/14/10 Generator Decals DCA-56SPX Generator DecalsGenerator Decals Cont inued DCA-56SPX Generator DecalsTypical Generator Grounding Application DCA-56SPX InstallationMounting Outdoor InstallationIndoor Installation When connecting the generatorOutput Terminal Panel GeneratorEngine Operating Panel Generator Control PanelMajor Components DCA-56SPX Major Components22 DCA-56SPX- Operation and Parts Manual REV. #1 04/22/10 DCA-56SPX Generator Control Panel DCA-56SPX Engine Operating Panel Auto On/Off Engine Controller Mpec DCA-56SPX Engine Operating PanelOutput Terminal Familiarization DCA-56SPX Output Terminal Panel Familiarization100VAC Gfci Receptacles DCA-56SPX Output Terminal Panel FamiliarizationOver Current Relay Connecting LoadsGenerator Amperage Single Phase LoadDCA-56SPX Load APPLICATION/MAXIMUM Amperage Motors and motor-drivenDCA-56SPX Gauge READING/TERMINAL Panel Connections Fuel Check DCA-56SPX SetupCircuit Breakers Lubrication OilRefueling Refueling ProcedureOperation FreezingWeather Cleaning the RadiatorAir Cleaner Fan Belt Tension Coolant Antifreeze/Summer Coolant/WaterAlternator BatteryBattery Cable Installation WiringDirect exhaust away from nearby personnel DCA-56SPX Generator START-UP Procedure ManualBefore Starting Engines exhaust contains harmful emissionsOn position Figure VoltmeterPlace the Mpec Control Switch in the Auto position Starting Auto ModeDCA-56SPX Generator SHUT-DOWN Procedures Normal Shutdown ProcedureEmergency Shutdown Procedure DCA-56SPX Maintenance Replacing Oil Filter Cleaning the Fuel StrainerAir Removal Check Oil LevelTo ensure adequate starting Battery Charger JacketWater Heater Power ConnectionsTrailer Maintenance DCA-56SPX -TRAILER MaintenanceCheck the wheel and drum for free rotation DCA-56SPX -TRAILER MaintenanceBrake Adjustment BrakesTires/Wheels/Lug Nuts TireWear/InflationSuspension Start all wheel lug nuts by hand Lug Nut Torque RequirementsDCA-56SPX -TRAILERWIRING Diagram Generator Wiring Diagram DCA-56SPX Generatorwiring DiagramDCA-56SPX Enginewiring Diagram Engine Troubleshooting DCA-56SPX -TROUBLESHOOTING EngineDCA-56SPX -TROUBLESHOOTING Engine Generator Troubleshooting DCA-56SPX -TROUBLESHOOTING GeneratorEngine Controller Troubleshooting Mpec DCA-56SPX -TROUBLESHOOTING Engine ControllerDCA-56SPX- Operation and Parts Manual REV. #1 04/14/10 QTY. Column DCA-56SPX Explanation of Code in Remarks ColumnPart number on this Suggested Spare Parts list DCA-56SPX Suggested Spare PartsDescription DCA-56SPX Generator Assy 0042510000 B4110100102B101070033 0012110035Control BOX ASSY. S/N 7800001~7800129 DCA-56SPX- Control BOX Assy0601808822 B42140038020226900680 022690024060 DCA-56SPX- Operation and Parts Manual REV. #1 04/22/10 B5223100004 0601802710601840073 0601840121DCA-56SPX- Engine and Radiator Assy 3345112403 B59232000341132402321 1132400791Engine & Radiator Assy 0269200500 06055113950603306395 0602021070DCA-56SPX- Outputterminal Assy 0039316000 B4231700903C9220100004 0801830804DCA-56SPX- Actuator Assy 0343502090 06021500810030006000 B5354200104DCA-56SPX- Battery Assy 0805002904 0168309531B9310500004 B9104000004DCA-56SPX- Muffler Assy 0602320101 B53301003030016910025 B5333000203DCA-56SPX- Fueltank Assy 0605501074 D53630008030845500104 0810105400DCA-56SPX- Enclosure Assy B5493100303 B5413001602B5413400004 B5423000402DCA-56SPX- Enclosure ASSY. 35A 0042308000 B445420660234A B5493401704 0019108055DCA-56SPX- Rubber Seals Assy 0228901120 02289016600228900915 0228900745DCA-56SPX- Nameplate and Decals Assy M15000220 C9505300004C90530000 M155000220384 DCA-56SPX- Operation and Parts Manual REV. #1 04/22/10 DCA-56SPX- Operation and Parts Manual REV. #1 04/14/10 HERE’S HOW to GET Help

DCA-56SPX specifications

The Multiquip DCA-56SPX is a versatile and robust portable generator designed for a variety of applications, from construction sites to outdoor events. This generator combines performance, reliability, and user-friendly features, making it an essential tool for both professionals and DIY enthusiasts.

At the heart of the DCA-56SPX is a powerful Yanmar diesel engine that delivers a maximum output of 56 kVA. This generator is engineered for high efficiency and longevity, with a robust design that allows it to run for extended periods under heavy loads. The engine also adheres to stringent emissions standards, ensuring environmentally friendly operation without compromising performance.

One of the standout features of the DCA-56SPX is its advanced digital control panel. This user-friendly interface provides real-time monitoring of key parameters, such as voltage, frequency, and total runtime. It simplifies the operation and maintenance of the generator, enabling users to make informed decisions about power management. The control panel also includes safety features, such as low oil pressure and high-temperature shutdowns, to protect the engine from potential damage.

The DCA-56SPX is also equipped with a sound-attenuated enclosure, significantly reducing noise levels during operation. This feature is particularly beneficial in urban environments or areas where quiet operation is a priority. Moreover, the durable, weather-resistant design of the generator ensures reliable performance in various outdoor conditions.

Portability is another key characteristic of the DCA-56SPX. The generator is fitted with heavy-duty wheels and a sturdy frame that allows for easy transport across job sites. In addition to its mobility, the unit is designed for easy access to service points, facilitating quick maintenance and minimizing downtime.

Flexibility is further enhanced by the generator's multiple output options, including 120/240V single phase and 120/208V three-phase configurations. This versatility allows users to connect various tools and equipment, making the DCA-56SPX suitable for numerous applications, from powering construction machinery to providing backup power during outages.

Overall, the Multiquip DCA-56SPX stands out due to its robust design, efficient engine, advanced control technologies, and user-oriented features. It is an excellent investment for those seeking a reliable power source that can handle demanding tasks while ensuring safety, portability, and efficiency. Whether for construction, event planning, or emergency situations, the DCA-56SPX delivers dependable performance to meet diverse power needs.