Multiquip operation manual DCA-56SPX Safety Message Alert Symbols, Hazard Symbols

Page 8

DCA-56SPX — SAFETY MESSAGE ALERT SYMBOLS

FORYOUR SAFETY AND THE SAFETY OF OTHERS!

HAZARD SYMBOLS

Safety precautions should be followed at all times when operating this equipment. Failure to read and understand the Safety Messages and Operating Instructions could result in injury to yourself and others.

This Owner's Manual has been

developed to provide complete

NOTE instructions for the safe and efficient operation of the MQ Power Model DCA-56SPX

Whisperwatt™ Generator.

Before using this generator, ensure that the operating individual has read and understands all instructions in this manual.

SAFETY MESSAGE ALERT SYMBOLS

The three (3) Safety Messages shown below will inform you about potential hazards that could injure you or others. The Safety Messages specifically address the level of exposure to the operator, and are preceded by one of three words: DANGER, WARNING, or CAUTION.

DANGER

You WILL be KILLED or SERIOUSLY injured if you do not follow directions.

WARNING

You COULD be KILLED or SERIOUSLY injured if you do not follow directions.

CAUTION

You CAN be injured if you do not follow directions

Potential hazards associated with the operation of this equipment will be referenced with "Hazard Symbols" which appear throughout this manual, and will be referenced in conjunction with Safety "Message Alert Symbols".

WARNING - LETHAL EXHAUST GASES

Gasoline engine exhaust gases contain poisonous carbon monoxide. This gas is colorless and odorless, and can cause DEATH if inhaled. NEVER operate this

equipment in a confined area or enclosed structure that does not provide ample free flow air.

WARNING - EXPLOSIVE FUEL

Gasoline is extremely flammable, and its vapors can cause an explosion if ignited. DO NOT start the engine near spilled fuel or combustible fluids. DO NOT fill the fuel tank while the engine is running or hot.

DO NOT overfill tank, since spilled fuel could ignite if it comes into contact with hot engine parts or sparks from the ignition system. Store fuel in approved containers, in well-ventilated areas and away from sparks and flames. NEVER use fuel as a cleaning agent.

WARNING - BURN HAZARDS

Engine components can generate extreme heat.To prevent burns, DO NOT touch these areas while the engine is running or immediately after operations. NEVER operate the engine with heat shields or heat guards removed.

DANGER - ELECTROCUTION HAZARDS

During operation of this generator, there exists the possibility of electrocution, electrical shock or burn, which can cause severe bodily harm or even DEATH!

PAGE 8 — DCA-56SPX— OPERATION AND PARTS MANUAL — REV. #1 (04/22/10)

Image 8
Contents Parts List NO. B4871301604 S/N 3796699~ Model DCA-56SPXProposition 65WARNING Diesel engine exhaust and someDCA-56SPX- Operation and Parts Manual REV. #1 04/14/10 Table of Contents Parts Ordering Procedures Ordering parts has never been easierDCA-56SPX Specifications DCA-56SPX Dimensions TOP, Side and Front DimensionsDCA-56SPX Safety Message Alert Symbols Hazard SymbolsDCA-56SPX Safety Message Alert Symbols General Safety DCA-56SPX Rules for Safe OperationInjury People Carbon monoxide gasMaintenance Safety DCA-56SPX Rules for Safe OperationBattery Safety DCA-56SPX Rules for Safe OperationDeath Towing and Transporting Safety Guidelines section in this manualDCA-56SPX- Operation and Parts Manual REV. #1 04/14/10 DCA-56SPX Generator Decals Generator DecalsDCA-56SPX Generator Decals Generator Decals Cont inuedDCA-56SPX Installation Typical Generator Grounding ApplicationOutdoor Installation Indoor InstallationWhen connecting the generator MountingGenerator Engine Operating PanelGenerator Control Panel Output Terminal PanelDCA-56SPX Major Components Major Components22 DCA-56SPX- Operation and Parts Manual REV. #1 04/22/10 DCA-56SPX Generator Control Panel DCA-56SPX Engine Operating Panel DCA-56SPX Engine Operating Panel Auto On/Off Engine Controller MpecDCA-56SPX Output Terminal Panel Familiarization Output Terminal FamiliarizationDCA-56SPX Output Terminal Panel Familiarization 100VAC Gfci ReceptaclesConnecting Loads Over Current RelaySingle Phase Load DCA-56SPX Load APPLICATION/MAXIMUM AmperageMotors and motor-driven Generator AmperageDCA-56SPX Gauge READING/TERMINAL Panel Connections DCA-56SPX Setup Circuit BreakersLubrication Oil Fuel CheckRefueling Procedure RefuelingCleaning the Radiator Air Cleaner Fan Belt TensionCoolant Antifreeze/Summer Coolant/Water Operation FreezingWeatherBattery Battery Cable InstallationWiring AlternatorDCA-56SPX Generator START-UP Procedure Manual Before StartingEngines exhaust contains harmful emissions Direct exhaust away from nearby personnelVoltmeter On position FigureStarting Auto Mode Place the Mpec Control Switch in the Auto positionEmergency Shutdown Procedure DCA-56SPX Generator SHUT-DOWN ProceduresNormal Shutdown Procedure DCA-56SPX Maintenance Cleaning the Fuel Strainer Air RemovalCheck Oil Level Replacing Oil FilterBattery Charger JacketWater Heater Power Connections To ensure adequate startingDCA-56SPX -TRAILER Maintenance Trailer MaintenanceDCA-56SPX -TRAILER Maintenance Brake AdjustmentBrakes Check the wheel and drum for free rotationSuspension Tires/Wheels/Lug NutsTireWear/Inflation Lug Nut Torque Requirements Start all wheel lug nuts by handDCA-56SPX -TRAILERWIRING Diagram DCA-56SPX Generatorwiring Diagram Generator Wiring DiagramDCA-56SPX Enginewiring Diagram DCA-56SPX -TROUBLESHOOTING Engine Engine TroubleshootingDCA-56SPX -TROUBLESHOOTING Engine DCA-56SPX -TROUBLESHOOTING Generator Generator TroubleshootingDCA-56SPX -TROUBLESHOOTING Engine Controller Engine Controller Troubleshooting MpecDCA-56SPX- Operation and Parts Manual REV. #1 04/14/10 DCA-56SPX Explanation of Code in Remarks Column QTY. ColumnDescription Part number on this Suggested Spare Parts listDCA-56SPX Suggested Spare Parts DCA-56SPX Generator Assy B4110100102 B1010700330012110035 0042510000DCA-56SPX- Control BOX Assy Control BOX ASSY. S/N 7800001~7800129B4214003802 02269006800226900240 060180882260 DCA-56SPX- Operation and Parts Manual REV. #1 04/22/10 060180271 06018400730601840121 B5223100004DCA-56SPX- Engine and Radiator Assy B5923200034 11324023211132400791 3345112403Engine & Radiator Assy 0605511395 06033063950602021070 0269200500DCA-56SPX- Outputterminal Assy B4231700903 C92201000040801830804 0039316000DCA-56SPX- Actuator Assy 0602150081 0030006000B5354200104 0343502090DCA-56SPX- Battery Assy 0168309531 B9310500004B9104000004 0805002904DCA-56SPX- Muffler Assy B5330100303 0016910025B5333000203 0602320101DCA-56SPX- Fueltank Assy D5363000803 08455001040810105400 0605501074DCA-56SPX- Enclosure Assy B5413001602 B5413400004B5423000402 B5493100303DCA-56SPX- Enclosure ASSY. B4454206602 34A B54934017040019108055 35A 0042308000DCA-56SPX- Rubber Seals Assy 0228901660 02289009150228900745 0228901120DCA-56SPX- Nameplate and Decals Assy C9505300004 C90530000M1550002203 M1500022084 DCA-56SPX- Operation and Parts Manual REV. #1 04/22/10 DCA-56SPX- Operation and Parts Manual REV. #1 04/14/10 HERE’S HOW to GET Help

DCA-56SPX specifications

The Multiquip DCA-56SPX is a versatile and robust portable generator designed for a variety of applications, from construction sites to outdoor events. This generator combines performance, reliability, and user-friendly features, making it an essential tool for both professionals and DIY enthusiasts.

At the heart of the DCA-56SPX is a powerful Yanmar diesel engine that delivers a maximum output of 56 kVA. This generator is engineered for high efficiency and longevity, with a robust design that allows it to run for extended periods under heavy loads. The engine also adheres to stringent emissions standards, ensuring environmentally friendly operation without compromising performance.

One of the standout features of the DCA-56SPX is its advanced digital control panel. This user-friendly interface provides real-time monitoring of key parameters, such as voltage, frequency, and total runtime. It simplifies the operation and maintenance of the generator, enabling users to make informed decisions about power management. The control panel also includes safety features, such as low oil pressure and high-temperature shutdowns, to protect the engine from potential damage.

The DCA-56SPX is also equipped with a sound-attenuated enclosure, significantly reducing noise levels during operation. This feature is particularly beneficial in urban environments or areas where quiet operation is a priority. Moreover, the durable, weather-resistant design of the generator ensures reliable performance in various outdoor conditions.

Portability is another key characteristic of the DCA-56SPX. The generator is fitted with heavy-duty wheels and a sturdy frame that allows for easy transport across job sites. In addition to its mobility, the unit is designed for easy access to service points, facilitating quick maintenance and minimizing downtime.

Flexibility is further enhanced by the generator's multiple output options, including 120/240V single phase and 120/208V three-phase configurations. This versatility allows users to connect various tools and equipment, making the DCA-56SPX suitable for numerous applications, from powering construction machinery to providing backup power during outages.

Overall, the Multiquip DCA-56SPX stands out due to its robust design, efficient engine, advanced control technologies, and user-oriented features. It is an excellent investment for those seeking a reliable power source that can handle demanding tasks while ensuring safety, portability, and efficiency. Whether for construction, event planning, or emergency situations, the DCA-56SPX delivers dependable performance to meet diverse power needs.