Multiquip ga6HB, ga6HEB manual ElECTRiCAl sAFETY, Power Cord/Cable safety, Grounding safety

Page 7

Safety Information

„NEvER use fuel as a cleaning agent.

„dO NOT smoke around or near the equipment. Fire or explosion could result

from fuel vapors or if fuel is spilled on a hot engine.

ElECTRiCAl sAFETY

dANgER

„Turn generator and all circuit breakers OFF before performing maintenance on the generator or making contact with output receptacles.

„NEvER insert any objects into the output receptacles during operation.

This is extremely dangerous. The possibility exists of electrical shock, electrocution or death.

„Backfeed to a utility system can cause

electrocution and/or property damage. NEvER connect the generator to a building’s electrical system without a transfer switch or other approved

device. All installations should be

performed by a licensed electrician in accordance with all applicable laws and electrical codes. Failure to do so could result in electrical shock or burn, causing serious injury or even death.

power Cord/Cable safety

dANgER

„NEvER let power cords or cables lay in water.

„NEvER stand in water while AC power from the generator is being transferred to a load.

„NEvER use damaged or worn cables or cords when connecting equipment to generator. Inspect for cuts in the insulation.

„ NEvER grab or touch a live power cord or cable with wet hands. The possibility exists of electrical shock, electrocution or death.

„Make sure power cables are securely connected to the generator’s output receptacles. Incorrect connections may cause electrical shock and damage to the generator.

NOTICE

„AlWAYs make certain that proper power or extension cord has been selected for the job. See Cable Selection Chart in this manual.

grounding safety

dANgER

„AlWAYs make sure that electrical circuits are properly grounded to a suitable earth ground (ground rod) per the National Electrical Code (NEC) and local codes before operating generator. severe injury or death by electrocution can result from operating an ungrounded generator.

„NEvER use gas piping as an electrical ground.

BATTERY sAFETY (ElECTRiC sTART ONlY)

dANgER

„dO NOT drop the battery. There is a possibility that the battery will explode.

„dO NOT expose the battery to open fl ames, sparks, cigarettes, etc.The battery contains combustible gases and liquids. If these

gases and liquids come into contact with a fl ame or spark, an explosion could occur.

„dO NOT charge battery if frozen. Battery can explode. When frozen, warm the battery to at least 61°F (16°C).

WARNiNg

„ AlWAYs wear safety glasses when handling the battery to avoid eye irritation. The battery contains acids that can cause

injury to the eyes and skin.

„Use well-insulated gloves when picking up the battery.

„AlWAYs keep the battery charged. If the battery is not charged, combustible gas will build up.

„AlWAYs recharge the battery in a well-ventilated environment to avoid the risk of a dangerous concentration of combustible gasses.

GA6HB/6HEB 60 hz GENERATOR • operation and parts manual — rev. #0 (03/13/14) — page 7

Image 7
Contents Model ga6HB/ga6HEB GA6HB/GA6HEB Portable 60 Hz Generator Table of ContentsChoose from three easy options SAFETY mEssAgEs Safety InformationGENERATOR sAFETY GENERAl sAFETYFuEl sAFETY ENgiNE sAFETYBattery sAFETY ElECTRiC sTART ONlY ElECTRiCAl sAFETYPower Cord/Cable safety Grounding safetyENviRONmENTAl sAFETY/dECOmmissiONiNg TRANspORTiNg sAFETYEmission Control label EmissiONs iNFORmATiONGA6HB GA6HEB Specifications gENERATOREffects of Altitude and Heat Specifications engineGA-6HB DimensionsPage Connecting the Ground InstallationGenerator Grounding Outdoor InstallationIndoor Installation PlacementGenerator General informationControl Panel GA-6HEB Components generatorFull Power Switch GA-6H Extension Cable General Inspection Prior to Operation Ground Power ToolsEngine Oil Check INSPECTION/setupBattery Setup GA6HBE Before StartingBefore Starting the Engine OperationStarting the Engine Recoil Start 120 Stopping the Engine Normal Shutdown Operation/shutdownEmergency Shutdown Generator Storage Preparation for long term storageFirst Every MaintenancePiping and Hose Connection MaintenanceWiring DailySpark arrester cleaning Engine Air CleanerPolarity Battery ga6HEBBattery Cable Installation Testing the Gfci Module240 120 Page Generator Engine Generator wiring diagram ga6hbSW4 Generator wiring digram ga6hebTroubleshooting Engine Troubleshooting EngineAir cleaner dirty? Clean or replace air cleaner Troubleshooting Generator Page Explanation of Code in Remarks Column Spark Plug Suggested Spare PartsCAP Fuel Tank Filter FuelGA6HEB GA6HB/GA6HEB- nameplate and decalS AssyDecal MQ POWER, GA-6H Decal AIR CleanerDecal Choke GA6HB/GA6HEB Generator Assy Bearing Includes Items W/#Rectifier D3SB80 Surge AbsorberGA6HB/GAGHEB Control BOX Assy Start SWITCH, GA6HEB Full Power SwitchIdle Control Switch Operation SwitchGA6HB/GA6HEB Pipe Frame Assy Base Pipe FRAME, GA6HBPipe FRAME, GA6HEB BracketGA6HEB Battery Assy Battery CABLE, Positive Battery BandBattery Bolt Battery CABLE, NegativeGA6HB/GA6HEB Muffler Assy ARRESTOR, Spar MufflerProtector SealHonda GX340R2EDE2/EDN2 AIR Cleaner Assy Base COMP, AIR Cleaner ELEMENT, AIR CleanerCase COMP, AIR Cleaner STAY, AIR CleanerHonda GX340R2EDE2/EDN2 Camshaft Assy ARM, Valve Rocker SPRING, Weight ReturnSeal Valve Stem ROD, PushHonda GX340R2EDE2/EDN2 Carburetor Assy Gasket SET COLLAR, SettingGASKET, AIR Cleaner CLIP, Wire HarnessHonda GX340R2EDE2/EDN2 Control Assy SPRING, Governor SPRING, Control AdjustingARM, Governor ROD, GovernorHonda GX340R2EDE2/EDN2 Crankcase Cover Assy Packing Crankcase Cover WEIGHT, GovernorHOLDER, Governor Weight PIN, Governor WeightHonda GX340R2EDE2/EDN2 Crankshaft Assy WEIGHT, Balancer Honda GX340R2EDE2/EDN2 CylINDER Barrel Assy NUT, Flange 10MM Switch ASSY., OIL LevelIncludes Items W/$ SHAFT, Governor ARMHonda GX340R2EDE2/EDN2 CylINDER Head Assy COVER, Cylinder Head GUIDE, Valve OS OptionalCLIP, Valve Guide GASKET, Cylinder HeadHonda GX340R2EDE2/EDN2 FAN Cover Assy Shroud COVER, FAN *NH1* BlackGROMMET, Drain Hole Honda GX340R2EDE2/EDN2 Flywheel Assy PULLEY, Starter FAN, CoolingNUT, Special 16MM Honda GX340R2EDE2/EDN2 Ignition Coil Assy Coil ASSY., Lamp 12V/25W CLAMP, WireGROMMET, Wire Harness ASSY., Engine WireHonda GX340R2EDE2/EDN2 Piston Assy PIN, Piston BOLT, Connecting RODRing SET, Piston STD Piston STDHonda GX340R2EDE2/EDN2 recoil starter Assy SPRING, Starter Return PULLEY, Recoil StarterRATCHET, Starter SPRING, FrictionHonda GX340R2EDE2 starter Motor Assy BRACKET, Front Contactor AssyArmature Complete BRACKET, CenterHonda GX340R2EDE2/EDN2 Solenoid Assy LEVER, Throttle SPRING, Choke ReturnSolenoid Assy Honda GX340R2EDE2/EDN2 Engine Decals Assy Emblem GX340 DECAL, AIR CleanerDECAL, Choke MARK, OIL CautionFREighT pOliCY Terms and Conditions of Sale PartsPage HERE’S HOW to GET Help

ga6HB, ga6HEB specifications

Multiquip has established itself as a leading manufacturer of innovative and reliable construction equipment. Among its impressive lineup, the GA6HEB and GA6HB generators stand out due to their advanced features and exceptional performance. Both models cater to a variety of applications, making them suitable for construction sites, events, and emergency power needs.

The GA6HEB generator is equipped with a powerful 6 kW output capability, which makes it ideal for powering tools and equipment in demanding environments. For those looking for a more efficient alternative, the GA6HB offers similar power with a focus on convenience and ease of use. Both units utilize a highly efficient engine, ensuring that fuel consumption is minimized while still delivering reliable power when needed.

One of the defining features of the GA6HEB and GA6HB is their innovative design. Constructed with high-quality materials, these generators are built to withstand the rigors of daily use. Their robust frames provide enhanced durability, ensuring longevity in harsh job site conditions. Additionally, the compact design of both models allows for easy transport and storage, making them a practical choice for contractors and event planners alike.

In terms of technology, these generators include advanced control systems that enhance usability. The user-friendly interface provides operators with vital information at a glance, including voltage output, hour meters, and maintenance reminders. This focus on intuitive operation ensures that even those with minimal experience can efficiently manage these units.

Noise reduction technology is another significant characteristic of the GA6HEB and GA6HB. These generators are designed to operate quietly, allowing for use in noise-sensitive environments without disturbing nearby activities. This feature is particularly beneficial for outdoor events and residential applications, where peace and tranquility are paramount.

Fuel efficiency and runtime are critical for users, and both models deliver impressive performance in this regard. With extended run times on a single tank of fuel, the GA6HEB and GA6HB are perfect for long-term projects where consistent power is needed without frequent refueling.

Overall, the Multiquip GA6HEB and GA6HB generators are exemplary choices for various power needs. Their combination of robust construction, advanced technology, and user-friendly design makes them valuable assets for any project requiring reliable and efficient power solutions. Whether for professional contractors or casual users, these models promise the performance and dependability that Multiquip is renowned for.