Multiquip GAC-6HZR Operation/shutdown, Stopping the Engine Normal Shutdown, Emergency Shutdown

Page 23

operation/shutdown

12.Read voltmeter on front panel of generator (Figure 20) and verify that 240 VAC is displayed. Using an external voltmeter as shown in Figure 20, verify that 240 VAC is present at the 240V twist-lock receptacle.

2.Place GFCI circuit breaker (Figure 22) in the OFF positing.

Figure 20. 240V Receptacle

NOTICE

When using a combination of dual receptacles, total load should not exceed the rated capacity of the generator.

13.Connecting of loads (power tools, lighting ect.) to the generator receptacles can now be done.

Stopping the Engine (Normal Shutdown)

1.Place main circuit breaker (Figure 21) in the OFF position.

Figure 21. Main Circuit Breaker (OFF)

Figure 22. GFCI Circuit Breaker (OFF)

3. Place idle control switch (Figure 23) in the OFF position.

Figure 23. Idle Control switch (OFF)

4.Let engine run at idle with no load for 2-3 minutes.

5.To shut-down the engine, place the generator's operation switch (Figure 24) in the OFF position).

Figure 24. Operation Switch (OFF)

6.Place engine fuel valve lever (Figure 25) in the OFF position.

Figure 25. Engine Fuel Valve Lever (OFF)

7.Remove all loads from the generator.

Emergency Shutdown

8.Place operation switch (Figure 24) in the OFF position

GAC6HZR 60 hz GENERATOR • operation and parts manual — rev. #1 (03/31/10) — page 23

Image 23
Contents Model gaC-6HZR GAC6HZR Portable 60 Hz Generator Table of ContentsChoose from three easy options SaFeTY messages Safety InformationGeNeRaTOR saFeTY GeNeRal saFeTYFuel saFeTY ENgiNe saFeTYBaTTeRY saFeTY eleCTRiC sTaRT ONlY EleCTRiCal saFeTYPower Cord/Cable safety Grounding safetyENviRONmeNTal saFeTY TRaNspORTiNg saFeTYPage Specifications Generator Specifications gENERATOREffects of Altitude and Heat Specifications engine18.9 480 MM DimensionsPage Connecting the Ground InstallationGenerator Grounding Outdoor InstallationIndoor Installation PlacementControl Box General informationGenerator Honda Components generatorFuel Tank Fuel tank capacity is 5 gallons 19 liters Main/GFCI Circuit Breakers General Inspection Prior to Operation Ground Power ToolsExtension Cable Fuel Check Before StartingEngine Oil Check Starting the Engine OperationBefore Starting the Engine Place main circuit breaker in the on position Emergency Shutdown Operation/shutdownStopping the Engine Normal Shutdown Generator Storage Preparation for long term storageFirst Every MaintenanceWeekly MaintenanceEngine Air Cleaner DailySW2 Generator wiring digramEngine Troubleshooting Troubleshooting EngineWeak in power Water in fuel system? Troubleshooting Generator Page Explanation of Code in Remarks Column Suggested Spare Parts 5561058 and below GAC6HZR- nameplate and decalS AssyPart Name GAC6HZR- Generator Assy SET BOLT, Rotor RECTIFIER, D3SB80Surge Absorber BEARING, 6304 2RU NycmGAC6HZR- Control BOX Assy Slow Down Unit Idle Control SwitchOperation Switch Control BOXGAC6HZR- Muffler Assy Bracket MufflerBOLT, HEX Head GAC6HZR- Pipe Frame Assy Stopper Pipe FrameBase Rubber SuspensionHonda GX340K1/U1EDN2 AIR Cleaner Assy STAY, AIR Cleaner ELEMENT, AIR CleanerSEPARATOR, AIR Cleaner CASE, AIR CleanerHonda GX340K1/U1EDN2 Engine Camshaft Assy ARM, Valve Rocker SPRING, Weight ReturnIncludes ITEMS/W$ ROD, PushHonda GX340K1/U1EDN2 Engine Carburetor Assy Chamber SET, Float Gasket SETValve SET, Float Float SETHonda GX340K1/U1EDN2 Engine Carburetor Assy LEVER, Choke GASKET, AIR CleanerCLIP, Wire Harness STAY, SolenoidHonda GX340K1/U1EDN2 Engine Control Assy SPRING, Governor SPRING, Control AdjustingARM, Governor ROD, GovernorHonda GX340K1/U1EDN2 Engine Crankcase Cover Assy GASKET, Case Cover WEIGHT, GovernorHOLDER, Governor Weight PIN, Governor WeightHonda GX340K1/U1EDN2 Engine Crankshaft Assy WEIGHT, Balancer Honda GX340K1/U1EDN2 Engine Cylinder Barrel Assy BOLT, Drain Plug Switch ASSY., OIL LevelWIRE, Ground SHAFT, Governor ARMHonda GX340K1/U1EDN2 Engine Cylinder Head Assy COVER, Head GUIDE, Valve OS OptionalCLIP, Valve Guide GASKET, Cylinder HeadHonda GX340K1/U1EDN2 Engine FAN Assy GROMMET, Drain Hole COVER, FAN *NH1* BlackShroud Honda GX340K1/U1EDN2 Engine Flywheel Assy Flywheel COMP., Lamp FAN, CoolingPULLEY, Starter Honda GX340K1/U1EDN2 Engine Ignition Coil Assy HOLDER, Stop Switch Wire CLAMP, WireGROMMET, Wire WIRE, Stop Switch 470MMHonda GX340K1/U1EDN2 Engine Piston Assy PIN, Piston BOLT, Connecting RODRing SET, Piston STD Piston STDHonda GX340K1/U1EDN2 Engine Recoil Starter Assy SPRING, Starter Return PULLEY, Recoil StarterRATCHET, Starter SPRING, FrictionHonda GX340K1/U1EDN2 Engine Solenoid Assy Solenoid Assy SPRING, Choke ReturnLEVER, Throttle Honda GX340K1/U1EDN2 Engine Fuel Cock Assy CUP, Fuel Strainer PACKING, Fuel Strainer CUPRing Filter CUPHonda GX340K1/U1EDN2- Engine Decals Assy Emblem GX240 Honda DECAL, AIR CleanerDECAL, Choke DECAL, Choke GrayHonda GX340K1/U1EDN2 Engine Tool KIT BAG Tool Wrench COMP. Spark PlugHANDLE, BOX Wrench SapnnerFReigHT pOliCY Terms and Conditions of Sale PartsPage HERE’S HOW to GET Help

GAC-6HZR specifications

The Multiquip GAC-6HZR is a versatile and powerful gasoline generator designed for a wide range of applications, including construction sites, events, and emergency backup power. Built with reliability and performance in mind, this generator is an excellent choice for users seeking a robust power solution.

One of the main features of the GAC-6HZR is its impressive output capacity. With a maximum power output of 6,000 watts and a rated output of 5,500 watts, this generator can handle multiple tools and appliances simultaneously, making it an ideal choice for contractors and outdoor enthusiasts alike. The addition of a reliable Honda GX390 engine ensures optimal performance and fuel efficiency, allowing for extended run times between refueling.

The GAC-6HZR is equipped with an easy-to-read control panel that features multiple 120V and 240V outlets, a circuit breaker, and a gas gauge, providing users with everything they need to manage their power needs efficiently. The inclusion of a 12V DC outlet also allows for charging batteries, further enhancing its usability across different applications.

Safety considerations are paramount in the design of the GAC-6HZR. The generator includes a low-oil shutdown feature that automatically turns off the engine when oil levels drop to a dangerous level, preventing damage and extending the unit's lifespan. Additionally, its sturdy steel frame construction provides durability and protection against harsh environments.

The GAC-6HZR also integrates advanced technologies to enhance its performance and user experience. Its digital ignition system ensures easier starts in various conditions, while its noise-reducing design keeps operation quiet enough for use in residential areas or during events. Furthermore, the generator's compact and portable design, featuring ergonomically designed handles, allows for easy transportation and maneuvering on job sites or around the home.

In conclusion, the Multiquip GAC-6HZR is a powerful and reliable generator that is well-equipped to meet the demands of users in various fields. With its high output, advanced safety features, and user-friendly design, it stands out as a dependable power solution for anyone in need of portable electricity. Whether used for construction, events, or emergency power supply, the GAC-6HZR is designed to deliver exceptional performance and reliability.