A wide range of voltages are available to supply voltage for many different applications.Voltages are selected by using the voltage selector switch (Figure 13). To obtain some of the voltages as listed in Table 7 (see below) will require a fine adjustment using the voltage regulator (VR) control knob located on the control panel.

Voltage Selector Switch

The voltage selector switch (Figure 13) is located above the output terminal panel’s Hard Wire Hook-up Panel. It has been provided for ease of voltage selection.

Generator Amperage

Table 8 shows the maximum amps the generator can provide. DO NOT exceed the maximum amps as listed..

Table 8. Generator Maximum Amps

Rated Voltage

Maximum Amps

 

 

1Ø 120 Volt

100 amps (4 wire)

108A x 2 (Zigzag)

 

1Ø 240 Volt

50 amps (4 wire)

108A (Zigzag)

 

3Ø 240 Volt

108 amps

 

 

3Ø 480 Volt

54 amps

 

 

Figure 13. Voltage Selector Switch

Voltage Selector Switch Locking Button

To lock the voltage selector switch, press and hold the red button located at the bottom of the switch. While holding the red button down, insert a pad lock into the hole next to the button to retain it in the inward locked position. When the lock is removed, the red button is spring loaded and will return to its normal outward unlocked position.

CAUTION

NEVER change the position of the voltage selector switch while the engine is running. ALWAYS place circuit breaker in the OFF position before selecting voltage.

Table 7. Voltages Available

UVWO Output

Voltage Selector Switch

Voltage Selector Switch

Terminal Lugs

3-Phase 240/139V Position

3-Phase 480/270V Position

 

 

 

 

 

 

 

Line-Line

208V

220V

240V

416V

440V

480V

 

 

 

 

 

 

 

Line-Neutral

120V

127V

139V

240V

254V

277V

 

 

 

 

 

 

 

Voltage Selector Switch Single-Phase 240/120V Position

 

 

 

 

 

 

 

 

Line-Neutral/

120V

N/A

N/A

240V

N/A

N/A

Line-Line

Line-Neutral

Line-Line

 

 

 

 

 

 

 

 

 

 

 

GFCI Receptacle Load Capability

The load capability of the GFCI receptacles is directly related to the voltage being supplied at either the output terminals or the 2 twist lock auxiliary receptacles.

Table 9 and Table 10 show what amount of current is available at the GFCI receptacles when the output terminals and twist lock receptacles are in use. Be careful that your load does not to exceed the available current capability at the receptacles.

Table 9. 1Ø GFCI Receptacle Load Capacity

KW in Use

Available Load

Twist Lock (C6369)

Current (Amps)

1Ø 240/120V

GFCI Duplex

5-20R 120V

 

26

0

24.8

5 amps/receptacle

23.6

10 amps/receptacle

 

 

22.4

15 amps/receptacle

 

 

21.2

20 amps/receptacle

 

 

Table 10. 3Ø Generator Maximum Amps

KVA in Use

Available Load

(UVWO Terminals)

Current (Amps)

3Ø 240/480V

GFCI Duplex

5-20R 120V

 

45

0 amps/receptacle

 

 

40.9

5 amps/receptacle

 

 

36.7

10 amps/receptacle

 

 

32.6

15 amps/receptacle

 

 

28.4

20 amps/receptacle

 

 

page 24 — DCA45ssk/ku3 60 hz Generator • operation and parts manual — rev. #0 (12/15/11)

Image 24
Contents Model dca45SSKU Model dca45SSKU3 Proposition 65 warning Reporting Safety Defects AdministratorTable of Contents DCA45SSKU/SSKU3 60 Hz GeneratorChoose from three easy options Safety Information SaFeTY messagesGeneral saFeTY GeneraTor saFeTYEngine saFeTY Restricted. If the air fl ow isIf operating in speed ranges above the maximum allowable Fuel saFeTY ToWing saFeTY„ never use fuel as a cleaning agent From fuel vapors or if fuel is spilled on a hot engineEleCTriCal saFeTY Grounding safetyPower Cord/Cable safety BaTTerY saFeTY EnvironmenTal saFeTYSpecifications DCA-45SSKU/KU3Dimensions DimensionsInstallation Typical Generator Grounding ApplicationOutdoor Installation Indoor InstallationMounting Generator GroundingGeneral Information Major Components Item noWill remain OFF. When the ignition Engine Control PanelGenerator control Panel Generator Control PanelOutput Terminal Familiarization Terminal legs O and Ground are considered bonded groundsOutput Terminal Panel is provided with the following Removing the Plastic Face Plate Hard Wire Hookup Panel VAC Gfci ReceptaclesConnecting Loads Over Current RelaySingle Phase Load Three Phase LoadLoad Application Voltage Selector Switch Voltage Selector Switch Locking ButtonGenerator Output Voltages Generator AmperageHow to Read the ac ammeter and ac voltage gauges Generator OUTPUTS/gauge readingAC Voltmeter Gauge Reading AC Ammeter Gauge ReadingUvwo Terminal Output Voltages 3Ø-240/139 Uvwo Terminal Output Voltages3Ø-208V/1Ø-120V Uvwo Terminal Output Voltages 3Ø-480/277V Uvwo Terminal Output Voltages 1Ø-240/120V Uvwo Terminal Output VoltagesInspection/SETUP Circuit BreakersLubrication Oil Fuel CheckRefueling Procedure Remove fuel cap and fill tank as shown in FigureCleaning the Radiator Air Cleaner Fan Belt TensionCoolant Antifreeze/Summer Coolant/ Water Operation in Freezing WeatherBattery Battery Cable InstallationWiring AlternatorBefore Starting StartingEngine’s exhaust contains harmful emissions Place the engine speed control switch in the RUN position up Normal Shutdown Procedure Emergency Shutdown ProcedureAutomatic Shut-down System Maintenance General Inspection Air CleanerAir Cleaner with Dust Indicator Cleaning Inside the Fuel Tank Fuel AdditionRemoving Water from the Fuel Tank Fuel Tank InspectionRadiator Cleaning Air RemovalCheck Oil Level Replacing Oil FilterJacketWater Heater and Internal Battery Optional Battery Charger and Jacket Water Heater optionTrailer Maintenance Trailer MaintenanceCoupler Type of hitch used on the trailer for towing Brake Adjustment BrakesHydraulic Surge Brakes ActuatorTires/Wheels/Lug Nuts Tire Wear/InflationSuspension Lug Nut Torque Requirements Never use an pneumatic air gun to tighten wheel lug nutsTrailer Wiring Diagram Trailer/Towing Vehicle Wiring DiagramGenerator Wiring Diagram Generator Wiring DiagramEngine Wiring Diagram Engine Wiring DiagramTroubleshooting Generator Generator TroubleshootingPage Explanation of Code in Remarks Column Suggested Spare Parts To 3 unitsGenerator Assy B3110001302 060182008306018 B3120100804Control box Assy M1213002012 Y0330000555Y0330000255 Y0330000190Control box Assy 0027105010 M9220100004Y0080200007 M1224100104Engine and Radiator Assy M1923200154 1G541970111663143562 1C02032433Engine and Radiator Assy 5160137670 SWITCH, thermometer T106365660 Y01991010000193601300 0605515170Output Terminal Assy M1230700103 M9220100204M9220100104 0039310000Battery Assy 0602220199 M9310500014M9103000304 0602220920Muffler Assy B3331102203 B33340014031925812231 0030410000Fuel Tank Assy M1363002602 06055050700605501072 0605516090Enclosure Assy M1413004202 M1413400004M1423003102 M1493110203Enclosure Assy 0019108055 36A 004230800036B 031108160 M1453006213Rubber Seals Assy REMArks Nameplate and Decals Assy M9522000504 M92200050M9520000104 M92000010Terms and Conditions of Sale Parts Freight PolicyPage HERE’S HOW to GET Help

DCA45SSKU, DCA45SSKU3 specifications

The Multiquip DCA45SSKU3 and DCA45SSKU are advanced diesel generators designed for a variety of applications, making them an ideal choice for contractors, event planners, and anyone needing reliable power solutions. With a robust design and cutting-edge technologies, these generators stand out in their class for performance and durability.

One of the main features of the DCA45SSKU3 and DCA45SSKU is their impressive power output. Offering a prime power capacity of 45 kVA, these generators are equipped with a powerful Yanmar engine that provides reliable and efficient performance. The engine operates at low speed, which not only enhances fuel efficiency but also reduces noise levels, making these generators suitable for use in noise-sensitive environments.

The generators come equipped with a fully integrated control panel, featuring an intuitive digital display that allows users to monitor operating parameters such as voltage, frequency, and runtime. This user-friendly interface simplifies operation, ensuring that even those unfamiliar with generator technology can easily manage the generator's functions.

In terms of fuel capacity, the DCA45SSKU and DCA45SSKU3 are designed for extended run times. The large fuel tank allows for continuous operation, meaning users can depend on these generators for prolonged periods without frequent refueling, enhancing their suitability for long-duration projects and events.

Another remarkable characteristic is the trailer-mounted design, providing excellent portability. This feature enables users to easily transport the generator to different job sites or locations, making it perfect for construction sites, outdoor events, or emergency backup power situations. The rugged construction also ensures that the generator can withstand the wear and tear of being moved frequently.

Safety features are integral to the design of the DCA45SSKU3 and DCA45SSKU. The generators are equipped with automatic shutdown mechanisms in case of low oil pressure or overheating, protecting the unit from damage and ensuring safe operation. Additionally, the sound-attenuated enclosure minimizes noise pollution, a crucial consideration for operations in populated areas.

In summary, the Multiquip DCA45SSKU3 and DCA45SSKU generators are powerful, portable, and feature-rich solutions for anyone in need of reliable diesel power. With their advanced technology, fuel efficiency, and safety features, these generators are an excellent choice for a wide range of applications, ensuring that users can access the power they need, when they need it.