Multiquip DCA45SSKU3 manual JacketWater Heater and Internal Battery Optional

Page 38

Maintenance

JacketWater Heater and Internal Battery (OPTIONAL)

This generator can be equipped as an option with a jacket water heater and an internal battery charger. They are provided with electric cords to connect to a commercial power source.

These units will ONLY function when commercial power has been supplied to them (Figure 57). When using extension cords, refer to Table 6 for the correct size and length.

The battery charger should always be connected to a commercial power source to ensure that the battery does not get discharged.

When using the generator in hot climates there is no need to apply power to jacket water heater. However, if the generator will be used in cold climates, it is best to apply power to the jacket water heater at all times.

JACKET

WATER

HEATER

CONNECT TO EXTERNAL 120 VAC POWER SOURCE

Figure 57. Battery Charger and Jacket Water

Heater (option)

If the generator will be used daily, the battery should normally not require charging. If the generator will be idle (not used) for long periods of time, apply power to the battery charger receptacle via commercial power using a power cord of adequate size.

NOTICE

To ensure adequate starting capability, always have power applied to the generator's internal battery charger.

page 38 — DCA45ssk/ku3 60 hz Generator • operation and parts manual — rev. #0 (12/15/11)

Image 38
Contents Model dca45SSKU Model dca45SSKU3 Proposition 65 warning Reporting Safety Defects AdministratorTable of Contents DCA45SSKU/SSKU3 60 Hz GeneratorChoose from three easy options Safety Information SaFeTY messagesGeneral saFeTY GeneraTor saFeTYIf operating in speed ranges above the maximum allowable Engine saFeTYRestricted. If the air fl ow is „ never use fuel as a cleaning agent Fuel saFeTYToWing saFeTY From fuel vapors or if fuel is spilled on a hot enginePower Cord/Cable safety EleCTriCal saFeTYGrounding safety BaTTerY saFeTY EnvironmenTal saFeTYSpecifications DCA-45SSKU/KU3Dimensions DimensionsInstallation Typical Generator Grounding ApplicationMounting Outdoor InstallationIndoor Installation Generator GroundingGeneral Information Major Components Item noWill remain OFF. When the ignition Engine Control PanelGenerator control Panel Generator Control PanelOutput Terminal Panel is provided with the following Output Terminal FamiliarizationTerminal legs O and Ground are considered bonded grounds Removing the Plastic Face Plate Hard Wire Hookup Panel VAC Gfci ReceptaclesConnecting Loads Over Current RelayLoad Application Single Phase LoadThree Phase Load Generator Output Voltages Voltage Selector SwitchVoltage Selector Switch Locking Button Generator AmperageAC Voltmeter Gauge Reading How to Read the ac ammeter and ac voltage gaugesGenerator OUTPUTS/gauge reading AC Ammeter Gauge Reading3Ø-208V/1Ø-120V Uvwo Terminal Output Voltages Uvwo Terminal Output Voltages3Ø-240/139 Uvwo Terminal Output Voltages 3Ø-480/277V Uvwo Terminal Output Voltages 1Ø-240/120V Uvwo Terminal Output VoltagesLubrication Oil Inspection/SETUPCircuit Breakers Fuel CheckRefueling Procedure Remove fuel cap and fill tank as shown in FigureCoolant Antifreeze/Summer Coolant/ Water Cleaning the RadiatorAir Cleaner Fan Belt Tension Operation in Freezing WeatherWiring BatteryBattery Cable Installation AlternatorEngine’s exhaust contains harmful emissions Before StartingStarting Place the engine speed control switch in the RUN position up Automatic Shut-down System Normal Shutdown ProcedureEmergency Shutdown Procedure Air Cleaner with Dust Indicator MaintenanceGeneral Inspection Air Cleaner Removing Water from the Fuel Tank Cleaning Inside the Fuel TankFuel Addition Fuel Tank InspectionCheck Oil Level Radiator CleaningAir Removal Replacing Oil FilterJacketWater Heater and Internal Battery Optional Battery Charger and Jacket Water Heater optionCoupler Type of hitch used on the trailer for towing Trailer MaintenanceTrailer Maintenance Hydraulic Surge Brakes Brake AdjustmentBrakes ActuatorSuspension Tires/Wheels/Lug NutsTire Wear/Inflation Lug Nut Torque Requirements Never use an pneumatic air gun to tighten wheel lug nutsTrailer Wiring Diagram Trailer/Towing Vehicle Wiring DiagramGenerator Wiring Diagram Generator Wiring DiagramEngine Wiring Diagram Engine Wiring DiagramTroubleshooting Generator Generator TroubleshootingPage Explanation of Code in Remarks Column Suggested Spare Parts To 3 unitsGenerator Assy 06018 B31100013020601820083 B3120100804Control box Assy Y0330000255 M1213002012Y0330000555 Y0330000190Control box Assy Y0080200007 0027105010M9220100004 M1224100104Engine and Radiator Assy 1663143562 M19232001541G54197011 1C02032433Engine and Radiator Assy 0193601300 5160137670 SWITCH, thermometer T106365660Y0199101000 0605515170Output Terminal Assy M9220100104 M1230700103M9220100204 0039310000Battery Assy M9103000304 0602220199M9310500014 0602220920Muffler Assy 1925812231 B3331102203B3334001403 0030410000Fuel Tank Assy 0605501072 M13630026020605505070 0605516090Enclosure Assy M1423003102 M1413004202M1413400004 M1493110203Enclosure Assy 36B 031108160 001910805536A 0042308000 M1453006213Rubber Seals Assy REMArks Nameplate and Decals Assy M9520000104 M9522000504M92200050 M92000010Terms and Conditions of Sale Parts Freight PolicyPage HERE’S HOW to GET Help

DCA45SSKU, DCA45SSKU3 specifications

The Multiquip DCA45SSKU3 and DCA45SSKU are advanced diesel generators designed for a variety of applications, making them an ideal choice for contractors, event planners, and anyone needing reliable power solutions. With a robust design and cutting-edge technologies, these generators stand out in their class for performance and durability.

One of the main features of the DCA45SSKU3 and DCA45SSKU is their impressive power output. Offering a prime power capacity of 45 kVA, these generators are equipped with a powerful Yanmar engine that provides reliable and efficient performance. The engine operates at low speed, which not only enhances fuel efficiency but also reduces noise levels, making these generators suitable for use in noise-sensitive environments.

The generators come equipped with a fully integrated control panel, featuring an intuitive digital display that allows users to monitor operating parameters such as voltage, frequency, and runtime. This user-friendly interface simplifies operation, ensuring that even those unfamiliar with generator technology can easily manage the generator's functions.

In terms of fuel capacity, the DCA45SSKU and DCA45SSKU3 are designed for extended run times. The large fuel tank allows for continuous operation, meaning users can depend on these generators for prolonged periods without frequent refueling, enhancing their suitability for long-duration projects and events.

Another remarkable characteristic is the trailer-mounted design, providing excellent portability. This feature enables users to easily transport the generator to different job sites or locations, making it perfect for construction sites, outdoor events, or emergency backup power situations. The rugged construction also ensures that the generator can withstand the wear and tear of being moved frequently.

Safety features are integral to the design of the DCA45SSKU3 and DCA45SSKU. The generators are equipped with automatic shutdown mechanisms in case of low oil pressure or overheating, protecting the unit from damage and ensuring safe operation. Additionally, the sound-attenuated enclosure minimizes noise pollution, a crucial consideration for operations in populated areas.

In summary, the Multiquip DCA45SSKU3 and DCA45SSKU generators are powerful, portable, and feature-rich solutions for anyone in need of reliable diesel power. With their advanced technology, fuel efficiency, and safety features, these generators are an excellent choice for a wide range of applications, ensuring that users can access the power they need, when they need it.