Multiquip DCA45SSKU3 manual Explanation of Code in Remarks Column

Page 48

Explanation of Code in Remarks Column

The following section explains the different symbols and remarks used in the Parts section of this manual. Use the help numbers found on the back page of the manual if there are any questions.

NOTICE

The contents and part numbers listed in the parts section are subject to change without notice. Multiquip does not guarantee the availability of the parts listed.

Sample partS liSt

NO.

part NO.

part Name

QtY.

remarKS

1

12345

BOLT

1

INCLUDES ITEMS W/%

2%

 

WASHER, 1/4 IN

NOT SOLD SEPARATELY

2%

12347

WASHER, 3/8 IN....

1

MQ-45T ONLY

312348 HOSE ..................A/R ...MAKE LOCALLY

412349 BEARING ..............1 .....S/N 2345B AND ABOVE

NO. Column

Unique Symbols — All items with same unique symbol

(@, #, +, %, or >) in the number column belong to the same assembly or kit, which is indicated by a note in the “Remarks” column.

Duplicate item Numbers — Duplicate numbers indicate multiple part numbers, which are in effect for the same general item, such as different size saw blade guards in use or a part that has been updated on newer versions of the same machine.

NOTICE

When ordering a part that has more than one item number listed, check the remarks column for help in determining the proper part to order.

part NO. Column

Numbers Used — Part numbers can be indicated by a number, a blank entry, or TBD.

TBD (To Be Determined) is generally used to show a part that has not been assigned a formal part number at the time of publication.

A blank entry generally indicates that the item is not sold separately or is not sold by Multiquip. Other entries will be clarified in the “Remarks” Column.

QtY. Column

Numbers Used — Item quantity can be indicated by a number, a blank entry, or A/R.

A/R (As Required) is generally used for hoses or other parts that are sold in bulk and cut to length.

A blank entry generally indicates that the item is not sold separately. Other entries will be clarified in the “Remarks” Column.

remarKS Column

Some of the most common notes found in the “Remarks” Column are listed below. Other additional notes needed to describe the item can also be shown.

assembly/Kit — All items on the parts list with the same unique symbol will be included when this item is purchased.

Indicated by:

“INCLUDES ITEMS W/(unique symbol)”

Serial Number Break — Used to list an effective serial number range where a particular part is used.

Indicated by:

“S/N XXXXX AND BELOW”

“S/N XXXX AND ABOVE”

“S/N XXXX TO S/N XXX”

Specific model Number Use — Indicates that the part is used only with the specific model number or model number variant listed. It can also be used to show a part is NOT used on a specific model or model number variant.

Indicated by:

“XXXXX ONLY”

“NOT USED ON XXXX”

“make/Obtain locally” — Indicates that the part can be purchased at any hardware shop or made out of available items. Examples include battery cables, shims, and certain washers and nuts.

“Not Sold Separately”— Indicates that an item cannot be purchased as a separate item and is either part of an assembly/kit that can be purchased, or is not available for sale through Multiquip.

page 48 — DCA45ssk/ku3 60 hz Generator • operation and parts manual — rev. #0 (12/15/11)

Image 48
Contents Model dca45SSKU Model dca45SSKU3 Proposition 65 warning Reporting Safety Defects AdministratorTable of Contents DCA45SSKU/SSKU3 60 Hz GeneratorChoose from three easy options Safety Information SaFeTY messagesGeneral saFeTY GeneraTor saFeTYEngine saFeTY Restricted. If the air fl ow isIf operating in speed ranges above the maximum allowable Fuel saFeTY ToWing saFeTY„ never use fuel as a cleaning agent From fuel vapors or if fuel is spilled on a hot engineEleCTriCal saFeTY Grounding safetyPower Cord/Cable safety BaTTerY saFeTY EnvironmenTal saFeTYSpecifications DCA-45SSKU/KU3Dimensions DimensionsInstallation Typical Generator Grounding ApplicationOutdoor Installation Indoor InstallationMounting Generator GroundingGeneral Information Major Components Item noWill remain OFF. When the ignition Engine Control PanelGenerator control Panel Generator Control PanelOutput Terminal Familiarization Terminal legs O and Ground are considered bonded groundsOutput Terminal Panel is provided with the following Removing the Plastic Face Plate Hard Wire Hookup Panel VAC Gfci ReceptaclesConnecting Loads Over Current RelaySingle Phase Load Three Phase LoadLoad Application Voltage Selector Switch Voltage Selector Switch Locking ButtonGenerator Output Voltages Generator AmperageHow to Read the ac ammeter and ac voltage gauges Generator OUTPUTS/gauge readingAC Voltmeter Gauge Reading AC Ammeter Gauge ReadingUvwo Terminal Output Voltages 3Ø-240/139 Uvwo Terminal Output Voltages3Ø-208V/1Ø-120V Uvwo Terminal Output Voltages 3Ø-480/277V Uvwo Terminal Output Voltages 1Ø-240/120V Uvwo Terminal Output VoltagesInspection/SETUP Circuit BreakersLubrication Oil Fuel CheckRefueling Procedure Remove fuel cap and fill tank as shown in FigureCleaning the Radiator Air Cleaner Fan Belt TensionCoolant Antifreeze/Summer Coolant/ Water Operation in Freezing WeatherBattery Battery Cable InstallationWiring AlternatorBefore Starting StartingEngine’s exhaust contains harmful emissions Place the engine speed control switch in the RUN position up Normal Shutdown Procedure Emergency Shutdown ProcedureAutomatic Shut-down System Maintenance General Inspection Air CleanerAir Cleaner with Dust Indicator Cleaning Inside the Fuel Tank Fuel AdditionRemoving Water from the Fuel Tank Fuel Tank InspectionRadiator Cleaning Air RemovalCheck Oil Level Replacing Oil FilterJacketWater Heater and Internal Battery Optional Battery Charger and Jacket Water Heater optionTrailer Maintenance Trailer MaintenanceCoupler Type of hitch used on the trailer for towing Brake Adjustment BrakesHydraulic Surge Brakes ActuatorTires/Wheels/Lug Nuts Tire Wear/InflationSuspension Lug Nut Torque Requirements Never use an pneumatic air gun to tighten wheel lug nutsTrailer Wiring Diagram Trailer/Towing Vehicle Wiring DiagramGenerator Wiring Diagram Generator Wiring DiagramEngine Wiring Diagram Engine Wiring DiagramTroubleshooting Generator Generator TroubleshootingPage Explanation of Code in Remarks Column Suggested Spare Parts To 3 unitsGenerator Assy B3110001302 060182008306018 B3120100804Control box Assy M1213002012 Y0330000555Y0330000255 Y0330000190Control box Assy 0027105010 M9220100004Y0080200007 M1224100104Engine and Radiator Assy M1923200154 1G541970111663143562 1C02032433Engine and Radiator Assy 5160137670 SWITCH, thermometer T106365660 Y01991010000193601300 0605515170Output Terminal Assy M1230700103 M9220100204M9220100104 0039310000Battery Assy 0602220199 M9310500014M9103000304 0602220920Muffler Assy B3331102203 B33340014031925812231 0030410000Fuel Tank Assy M1363002602 06055050700605501072 0605516090Enclosure Assy M1413004202 M1413400004M1423003102 M1493110203Enclosure Assy 0019108055 36A 004230800036B 031108160 M1453006213Rubber Seals Assy REMArks Nameplate and Decals Assy M9522000504 M92200050M9520000104 M92000010Terms and Conditions of Sale Parts Freight PolicyPage HERE’S HOW to GET Help

DCA45SSKU, DCA45SSKU3 specifications

The Multiquip DCA45SSKU3 and DCA45SSKU are advanced diesel generators designed for a variety of applications, making them an ideal choice for contractors, event planners, and anyone needing reliable power solutions. With a robust design and cutting-edge technologies, these generators stand out in their class for performance and durability.

One of the main features of the DCA45SSKU3 and DCA45SSKU is their impressive power output. Offering a prime power capacity of 45 kVA, these generators are equipped with a powerful Yanmar engine that provides reliable and efficient performance. The engine operates at low speed, which not only enhances fuel efficiency but also reduces noise levels, making these generators suitable for use in noise-sensitive environments.

The generators come equipped with a fully integrated control panel, featuring an intuitive digital display that allows users to monitor operating parameters such as voltage, frequency, and runtime. This user-friendly interface simplifies operation, ensuring that even those unfamiliar with generator technology can easily manage the generator's functions.

In terms of fuel capacity, the DCA45SSKU and DCA45SSKU3 are designed for extended run times. The large fuel tank allows for continuous operation, meaning users can depend on these generators for prolonged periods without frequent refueling, enhancing their suitability for long-duration projects and events.

Another remarkable characteristic is the trailer-mounted design, providing excellent portability. This feature enables users to easily transport the generator to different job sites or locations, making it perfect for construction sites, outdoor events, or emergency backup power situations. The rugged construction also ensures that the generator can withstand the wear and tear of being moved frequently.

Safety features are integral to the design of the DCA45SSKU3 and DCA45SSKU. The generators are equipped with automatic shutdown mechanisms in case of low oil pressure or overheating, protecting the unit from damage and ensuring safe operation. Additionally, the sound-attenuated enclosure minimizes noise pollution, a crucial consideration for operations in populated areas.

In summary, the Multiquip DCA45SSKU3 and DCA45SSKU generators are powerful, portable, and feature-rich solutions for anyone in need of reliable diesel power. With their advanced technology, fuel efficiency, and safety features, these generators are an excellent choice for a wide range of applications, ensuring that users can access the power they need, when they need it.