Multiquip DCA20spxu2 manual Inspection/SETUP, Circuit Breakers, Lubrication Oil, Fuel Check

Page 27

inspection/SETUP

Circuit Breakers

To protect the generator from an overload, a 3-pole, 90 amp, main circuit breaker is provided to protect the U,O and V Output Terminals from overload. In addition two single-pole, 20 amp GFCI circuit breakers are provided to protect the GFCI receptacles from overload. Two 50 amp load circuit breakers have also been provided to protect the auxiliary receptacles from overload. Make sure to switch ALL circuit breakers to the OFF position prior to starting the engine.

Lubrication Oil

Fill the engine crankcase with lubricating oil through the filler hole, but DO NOT overfill. Make sure the generator is level and verify that the oil level is maintained between the two notches (Figure 17) on the dipstick. See Table 9 for proper selection of engine oil.

Figure 17. Engine Oil Dipstick

When checking the engine oil, be sure to check if the oil is clean. If the oil is not clean, drain the oil by removing the oil drain plug, and refill with the specified amount of oil as outlined in the ISUZU Engine Owner’s Manual. Oil should be warm before draining.

Other types of motor oils may be substituted if they meet the following requirements:

„„ API Service Classification CC/SC

„„API Service Classification CC/SD

„„API Service Classification CC/SE

„„API Service Classification CC/SF

Table 9. Recommended Motor Oil

Fuel Check

DANGER

Fuel spillage on a hot engine can cause a fire or explosion. If fuel spillage occurs, wipe up the spilled fuel completely to prevent fire hazards. NEVER smoke around or near the generator.

Refilling the Fuel System

CAUTION

ONLY properly trained personnel who have read and understand this section should refill the fuel tank system.

This generator has an internal fuel tank located inside the trailer frame and may also be equipped with an environmental fuel tank (Figure 18). ALWAYS fill the fuel tanks with clean fresh #2 diesel fuel. DO NOT fill the fuel tanks beyond their capacities.

Pay attention to the fuel tank capacity when replenishing fuel. The fuel tank cap must be closed tightly after filling. Handle fuel in a safety container. If the container does not have a spout, use a funnel. Wipe up any spilled fuel immediately.

Like it never even happened.R

EXTERNAL

FUEL TANKSERVPRO

FILLER NECK

INTERNAL

FUEL TANK

Figure 18. Trailer Fuel Tank

DCA20spxu2 servpro® • operation and parts manual — rev. #0 (09/23/13) — page 27

Image 27
Contents Model dca20spxu2 Proposition 65 warning Administrator Reporting Safety DefectsDCA20SPXU2 60Hz Generator Table of ContentsChoose from three easy options SaFetY messages Safety InformationGenerator saFetY General saFetYEngine saFetY Restricted. If the air fl ow isIf operating in speed ranges above the maximum allowable From fuel vapors or if fuel is spilled on a hot engine Fuel saFetYToWing saFetY „ never use fuel as a cleaning agentBatterY saFetY EleCtriCal saFetYPower Cord/Cable safety Grounding safetyLabel must remain with the engine for its entire life Environmental saFetY/deCommissioningEmissions inFormation Emission Control labelGenerator Specifications SpecificationsDimensions DimensionsTypical Generator Grounding Application InstallationGenerator Grounding Outdoor InstallationIndoor Installation MountingGeneral Information Item no Generator Major ComponentsTrailer Components Trailer Major ComponentsOFF Generator conTROL PanelOFF Engine Control PanelEngine control Panel Output Terminal Familiarization Terminal legs O and Ground are considered bonded groundsOutput Terminal Panel is provided with the following VAC Gfci Receptacles Removing the Plastic Face Plate Hard Wire Hookup PanelOver Current Relay Connecting LoadsSingle Phase Load Load Application/Generator outputGenerator Amperage UOV Terminal Output Voltages 1Ø-240 Output Terminal Voltage1Ø-120 Output Terminal Voltage Fuel Check Inspection/SETUPCircuit Breakers Lubrication OilRefueling Procedure Coolant Antifreeze/Summer Coolant/ WaterRemove fuel cap from filler neck and fill fuel tank Figure Operation in Freezing Weather Cleaning the RadiatorAir Cleaner Fan Belt Tension BatteryAlternator Battery Cable InstallationWiring When connecting battery do the followingEngine’s exhaust contains harmful emissions Generator START-UP Procedure manualBefore Starting Starting ManualVoltage Adjust Control Knob Place the Mpec Control Switch in the Auto position Starting Auto ModeBefore connecting this generator to any Without this transfer switchEmergency Shutdown Procedure Normal Shutdown ProcedureMaintenance General Inspection Air CleanerAir Cleaner with Dust Indicator Fuel Tank Inspection Cleaning Inside the Fuel TankFuel Addition Removing Water from the Fuel TankFlushing Out Radiator and Replacing Coolant Radiator CleaningCheck Oil Level Replacing Oil FilterJacket Water Heater/Battery Charger Wheel Bearings Trailer MaintenanceAdjustable Channel Wheel Hub AdjustmentLeaf Suspension Components Leaf SuspensionCommon Causes For loss oF trailer Trailer guidelinesCoupling to tHe toW veHiCle Driving ConditionsInoperaBle Brakes, ligHts or mirrors Trailer toWing tipsTrailer vin tag Side vieW mirrors EleCtriCal ConneCtorToW veHiCle Suspension sYstemBall HitCH Coupler SaFetY CHainsJaCkstand Coupler tYpesCoupling the trailer to the tow vehicle Ball Coupler Lock washer and hitch frameAttaching safety Chain Connecting trailer lightsUncoupling the Ball Hitch Pintle Coupler and pintle Hook Pintle HitCH CouplerCoupling trailer to tow vehicle pintle Coupler Tire saFetY Unsafe tires, lug nuts or WheelsBe sure lug nuts are tight before each tow Determining load limit of trailerStep Tighten lug nuts before each towDetermining load limit of tow vehicle step Tire FundamentalsP indicates the tire is for passenger vehicles Table a. speed rating Uniform tire Quality grading standards utQgsTire safety tips Tire repairReplacing Worn or damaged tires Lug nut torque requirements Lights and signalsWheel rims Wheels, Bearings and lug nutsFigure L. Trailer to Tow Vehicle Wiring Diagram Color Code Generator Wiring DiagramEngine Wiring Diagram Jacket Water Heater Wiring Diagram AC Voltmeter defective? Troubleshooting GeneratorTroubleshooting engine Troubleshooting engineDipstick Explanation of Code in Remarks Column Repair kit, Fuel Pump Suggested Spare PartsGenerator Assy 8001070003 B11100014027961025004 0601822643Control box Assy 0601870433 M12130014020330000480 0330000250Control box Assy 0601801040 M12230010030601807641 0601806844Engine and Radiator Assy M1303200304 M19232001048972606490 8943142633Engine and Radiator Assy 0605511395 06020225610603306590 0603300285Output Terminal Assy 0039308000 M1230700203M9220000204 M9220000104Battery Assy 0602220920 0602220185B9310500014 M9103000304Muffler Assy Replaces M1330100803M1333002803 8970420280Fuel Tank ASSY. Internal M1363200004 M1363000212Y0605505073 EE57348Fuel Tank ASSY. Trailer mOUNTED 84454 EE359766109204 5284Trailer Assy 9514 0205 SCREW, HHC 3/8 16 x 40019502 9503 NUT, Nyloc 5/8 9505 FENDER, 8 x 30 xBattery Charger Assy EE56557 LC12500234530 EE6009Jacket Water Heater Assy TPS051GT10000 HEATER, 500W, 120 VAC Enclosure Assy M1493104903 M1413003302M1413400004 M1423002302Enclosure Assy 34A M1493405704 M145300380333A M1493405604 M1453003903Rubber Seals Assy REMArks Nameplate and Decals Assy M15000190 M1550001803M15000180 M1550001904Nameplate and Decals Assy 38A$ EE57078 36$ EE5707236A$ EE57073 38$ EE57077FreigHt poliCY Terms and Conditions of Sale PartsServpro RMA Department is here to serve you Servpro Warranty/RMAIndustrial Blvd Gallatin, TN Phone

DCA20spxu2 specifications

The Multiquip DCA20SPXU2 is a powerful and versatile portable generator that has become a favorite among contractors and outdoor enthusiasts alike. Designed for reliability and efficiency, this unit boasts a range of features that make it suitable for various applications, from construction sites to recreational activities.

One of the standout characteristics of the DCA20SPXU2 is its robust engine. Powered by a reliable 20 kW diesel engine, this generator offers ample power to run essential tools and equipment, ensuring that users can depend on it for demanding tasks. The engine is not only powerful but also designed for fuel efficiency, helping users save on operating costs during extended use.

The DCA20SPXU2 features an impressive run time, with a large fuel tank that enables it to operate for long periods without requiring frequent refueling. This is particularly beneficial for projects that are located in remote areas or for outdoor events where electricity is critical.

Another key highlight of the DCA20SPXU2 is its advanced sound attenuation design. This generator operates quietly, adhering to stringent noise regulations, which is essential when working in residential or noise-sensitive environments. The sound-dampening technology helps to minimize sound levels, making it an excellent choice for events and job sites that demand a quieter operation.

Multiquip has also integrated a user-friendly control panel in the DCA20SPXU2, featuring intuitive gauges and indicators that provide vital information at a glance, such as fuel levels, output voltage, and operational status. This ease of use allows operators to quickly monitor performance and make necessary adjustments.

The generator is equipped with multiple outlets, including 120V and 240V options, ensuring that it can power a variety of tools and equipment simultaneously. This versatility enhances its appeal for users who require flexibility in their power source.

Durability is another hallmark of the DCA20SPXU2. Built with high-quality materials, the generator is designed to withstand tough conditions, making it an ideal companion for construction sites or outdoor adventures.

In conclusion, the Multiquip DCA20SPXU2 is a well-engineered portable generator that offers a blend of power, efficiency, and convenience. With its robust engine, quiet operation, user-friendly controls, and durable construction, it stands out as a reliable choice for both professional and recreational use, meeting the power needs of a variety of users.