Multiquip dca45ssiu4 manual Explanation of Code in Remarks Column

Page 50

Explanation of Code in Remarks Column

The following section explains the different symbols and remarks used in the Parts section of this manual. Use the help numbers found on the back page of the manual if there are any questions.

NOTICE

The contents and part numbers listed in the parts section are subject to change without notice. Multiquip does not guarantee the availability of the parts listed.

Sample partS lISt

no.

part no.

part name

QtY.

remarKS

1

12345

BOLT

1

INCLUDES ITEMS W/%

2%

 

WASHER, 1/4 IN

NOT SOLD SEPARATELY

2%

12347

WASHER, 3/8 IN.

..1

MQ-45T ONLY

312348 HOSE ..................A/R ...MAKE LOCALLY

412349 BEARING ..............1 .....S/N 2345B AND ABOVE

no. Column

Unique Symbols — All items with same unique symbol

(@, #, +, %, or >) in the number column belong to the same assembly or kit, which is indicated by a note in the “Remarks” column.

Duplicate Item Numbers — Duplicate numbers indicate multiple part numbers, which are in effect for the same general item, such as different size saw blade guards in use or a part that has been updated on newer versions of the same machine.

NOTICE

When ordering a part that has more than one item number listed, check the remarks column for help in determining the proper part to order.

part no. Column

Numbers Used — Part numbers can be indicated by a number, a blank entry, or TBD.

TBD (To Be Determined) is generally used to show a part that has not been assigned a formal part number at the time of publication.

A blank entry generally indicates that the item is not sold separately or is not sold by Multiquip. Other entries will be clarifi ed in the “Remarks” Column.

QtY. Column

Numbers Used — Item quantity can be indicated by a number, a blank entry, or A/R.

A/R (As Required) is generally used for hoses or other parts that are sold in bulk and cut to length.

A blank entry generally indicates that the item is not sold separately. Other entries will be clarifi ed in the “Remarks” Column.

remarKS Column

Some of the most common notes found in the “Remarks” Column are listed below. Other additional notes needed to describe the item can also be shown.

assembly/Kit — All items on the parts list with the same unique symbol will be included when this item is purchased.

Indicated by:

“INCLUDES ITEMS W/(unique symbol)”

Serial Number Break — Used to list an effective serial number range where a particular part is used.

Indicated by:

“S/N XXXXX AND BELOW” “S/N XXXX AND ABOVE” “S/N XXXX TO S/N XXX”

Specific model number Use — Indicates that the part is used only with the specifi c model number or model number variant listed. It can also be used to show a part is NOT used on a specifi c model or model number variant.

Indicated by:

“XXXXX ONLY”

“NOT USED ON XXXX”

“make/obtain locally” — Indicates that the part can be purchased at any hardware shop or made out of available items. Examples include battery cables, shims, and certain washers and nuts.

“Not Sold Separately” — Indicates that an item cannot be purchased as a separate item and is either part of an assembly/kit that can be purchased, or is not available for sale through Multiquip.

page 50 — DCA45SSIU4 60 hz Generator • operation and parts manual — rev. #1 (10/24/13)

Image 50
Contents Parts List NO. M1870301104 Model dca45ssiu4Proposition 65 warning Reporting Safety Defects AdministratorTable of Contents DCA45SSIU4 Generator Component DrawingsChoose from three easy options SaFetY SYmbolS Safety InformationSaFetY meSSageS General SaFetY Generator SAFETyIf operating in speed ranges above the maximum allowable Engine SAFETyRestricted. If the air fl ow is „ never use fuel as a cleaning agent FUel SaFetYTowing SAFETy From fuel vapors or if fuel is spilled on a hot engineGrounding Safety EleCtrICal SaFetYPower Cord/Cable Safety BATTERy SAFETyEmission Control label EnvIronmental SaFetY/DeCommISSIonIngEmISSIonS InFormatIon Label must remain with the engine for its entire lifeSpecifications ModelDimensions DimensionsInstallation Typical Generator Grounding ApplicationMounting Outdoor InstallationIndoor Installation Generator GroundingGeneral Information Major Components Item noGenerator Control Panel Generator Control PanelPage Engine Operating Panel Fuel Gauge Indicates amount of diesel fuel available Output Terminal Panel is provided with the following Output Terminal FamiliarizationTerminal legs O and Ground are considered bonded grounds Removing the Plastic Face Plate Hard Wire Hookup Panel VAC Gfci ReceptaclesConnecting Loads Over Current RelayLoad Application Single Phase LoadThree Phase Load Type of LoadGenerator Output Voltages Voltage Selector SwitchVoltage Selector Switch Locking Button Generator AmperageReading Voltage How to Read the Output Terminal GaugeGenerator OUTPUTS/gauge reading Reading Amperage3Ø-208V/1Ø-120V Uvwo Terminal Output Voltages Uvwo Terminal Output Voltages3Ø-240/139 Uvwo Terminal Output Voltages 3Ø-480/277V Uvwo Terminal Output Voltages 1Ø-240/120V Uvwo Terminal Output VoltagesLubrication Oil Inspection/SETUPCircuit Breakers Fuel CheckRefueling Procedure Only use #2 diesel fuel when refuelingCoolant Antifreeze/Summer Coolant/ Water Cleaning the RadiatorAir Cleaner Fan Belt Tension Operation in Freezing WeatherWiring BatteryBattery Cable Installation AlternatorStarting Place the engine speed switch in the LOW down positionBefore Starting Starting ManualEngine Speed Switch High OFF/RESET position Normal Shutdown ProcedureEmergency Shutdown Procedure Place the Mpec Control SwitchAir Cleaner with Dust Indicator MaintenanceGeneral Inspection Air Cleaner Removing Water from the Fuel Tank Cleaning Inside the Fuel TankFuel Addition Fuel Tank InspectionReplacing Oil Filter Radiator CleaningCheck Oil Level Flushing Out Radiator and Replacing CoolantCoupler Type of hitch used on the trailer for towing Trailer MaintenanceTrailer Maintenance Hydraulic Surge Brakes Brake AdjustmentBrakes ActuatorSuspension Tires/Wheels/Lug NutsTire Wear/Inflation Lug Nut Torque Requirements Never use an pneumatic air gun to tighten wheel lug nutsTrailer Wiring Diagram Trailer/Towing Vehicle Wiring DiagramGenerator Wiring Diagram Generator Wiring DiagramEngine Wiring Diagram Engine Wiring DiagramController Wiring Diagram Controller Wiring DiagramTroubleshooting Generator Symptom Possible Problem SolutionTroubleshooting Diagnostic lamp Method of OperationExplanation of Code in Remarks Column Suggested Spare Parts Qty DescriptionGenerator Assy 0601822664 B31100011020601820083 B3120100804Control box Assy 0330000415 M12130013020330000185 0330000165Control box Assy 5825500290 89424816108970119490 M1213500704Control box Assy M1224100104 06018101410601831395 0027105010Engine and Radiator Assy 8980188580 M19232001348980388550 0605000451Engine and Radiator Assy 0199900150 00169060200199900550 0605515106Output Terminal Assy M9220100104 M1230700103M9220100204 0039310000Battery Assy M9103000304 0602220199M9310500014 0602220920Muffler Assy 0016910025 M3330100902M1330100703 M1333002703Fuel Tank Assy 0605501072 M13630017020605505070 0605516090Enclosure Assy M1423002202 M1413003202M1413400004 M1493107903Enclosure Assy Part Name QTY Rubber Seals Assy REMArks Nameplate and Decals Assy M15550001304 M1550000204M1550000804 M1550002203Terms and Conditions of Sale Parts FreIght polICYPage HERE’S HOW to GET Help

dca45ssiu4 specifications

The Multiquip DCA45SSIU4 is a robust and versatile diesel generator designed to meet the demands of various applications, ranging from construction sites to emergency power backup. With a powerful engine and a comprehensive array of features, this generator is engineered to deliver reliable performance and fuel efficiency.

At the heart of the DCA45SSIU4 is its 45 kVA output capability, which is powered by a highly efficient Yanmar engine. This engine not only provides ample power but also features advanced emissions technology that meets stringent environmental regulations. Users can rely on the DCA45SSIU4 for consistent energy delivery while minimizing their carbon footprint, making it a great choice for eco-conscious projects.

One of the standout features of the DCA45SSIU4 is its compact design. The generator is housed within a durable weatherproof enclosure that ensures reliable operation in various conditions. The enclosure is sound attenuated, significantly reducing noise levels, which is critical for projects in urban or noise-sensitive areas. This design allows the generator to operate quietly without disturbing the surrounding environment.

The DCA45SSIU4 is equipped with state-of-the-art digital control technology, featuring an intuitive user interface that simplifies monitoring and operation. This control panel includes essential indicators for voltage, frequency, and running hours, enabling users to track performance and maintenance needs efficiently. The generator also has a built-in automatic start/stop function, which activates the unit when power is needed and turns it off when it is not, thus enhancing convenience and saving fuel.

Another notable characteristic is its versatility in fuel efficiency. The DCA45SSIU4 can operate for extended periods on a single tank of diesel, making it ideal for both short-term and long-term power needs. Additionally, its features include a robust frame with forklift pockets and lifting points, ensuring easy transportation and setup at job sites.

In conclusion, the Multiquip DCA45SSIU4 combines power, durability, and advanced technology, positioning itself as an excellent solution for anyone in need of reliable temporary or backup power. Its features, including a powerful Yanmar engine, compact design, digital control technology, and exceptional fuel efficiency, make it a top choice for professionals across various industries. Whether for construction, events, or emergency situations, the DCA45SSIU4 stands out as a dependable generator that meets modern demands.