Multiquip operation manual DCA10SPX4/DCA10SPXU4 Rules for Safe Operation, Malfunction

Page 11

DCA10SPX4/DCA10SPXU4 — RULES FOR SAFE OPERATION

ALWAYS be sure the operator is familiar with proper safety precautions and operation techniques before using generators.

NEVER leave the generator unattended, turn off engine when unattended.

Unauthorized equipment modifications will void all warranties.

ALWAYS ensure generator is on level ground before use.

DO NOT place hands or fingers inside generators engine compartment when engine is running.

NEVER run engine without air cleaner. Severe engine damage may occur.

NEVER change or adjust the engine speed which has been set at the factory prior to shipping.

Maintenance Safety

NEVER lubricate components or attempt service on a running machine.

High Temperatures – Always stop engine and allow the engine to cool before adding fuel, oil or performing service and maintenance functions. Contact with hot! components can cause serious burns.

Keep the machinery in proper running condition.

Fix damage to the machine immediately and replace any broken parts immediately.

ALWAYS replace any worn or damaged warning decals.

ALWAYS store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children and un-authorized personnel.

Power Cord Safety

NEVER let power cables or cords lay in water.

NEVER stand in water while AC power from the generators is being transfer to a load.

NEVER use a defective or frayed power cable. Check the cable for cuts in the insulation.

NEVER use a extension cord that is frayed or damaged where the insulation has been cut.

ALWAYS make certain that proper power or extension cord has been selected for the job See Table 6.

The electrical voltage required to operate the generator can cause severe injury or even death through physical contact with live circuits. Turn all circuit breakers OFF before performing maintenance on the generator.

Dispose of hazardous waste properly. Examples of potentially hazardous waste are used motor oil, fuel and fuel filters.

DO NOT use food or plastic containers to dispose of hazardous waste.

DO NOT pour waste, oil or fuel directly onto the ground, down a drain or into any water source.

Grounding Safety

ALWAYS make sure that electrical circuits are properly grounded per the National Electrical Code (NEC) and local codes before operating generator. Severe injury or death! by electrocution can result from operating an ungrounded generator.

ALWAYS make sure the generators are properly grounded to a suitable earth ground (GROUND ROD). See installation in this manual.

NEVER use gas piping as an electrical ground.

ALWAYS allow the machine a proper amount of time to cool before servicing.

ALWAYS service air cleaner frequently to prevent engine

malfunction.

ALWAYS disconnect the NEGATIVE battery terminal before performing service on the generator.

Follow all battery safety guidelines listed in this manual when handleing or servicing the generator.

DCA10SPX4/DCA10SPXU4 — OPERATION AND PARTS MANUAL — REV. #0 (08/05/09) — PAGE 11

Image 11
Contents Model DCA10SPX4 Model DCA10SPXU4 DCA10SPX4/DCA10SPXU4 Proposition 65 Warning Diesel engine exhaust and someDCA10SPX4/DCA10SPXU4 Note Component Drawings Ordering parts has never been easier DCA10SPX4/DCA10SPXU4 Parts Ordering ProceduresDCA10SPX4/DCA10SPXU4 Specifications Dimension ft. mm DCA10SPX4/DCA10SPXU4 Dimensions TOP, Side and FrontHazard Symbols DCA10SPX4/DCA10SPXU4 Safety Message Alert SymbolsDCA10SPX4/DCA10SPXU4 Safety Message Alert Symbols Off Deadly carbon Monoxide gas General SafetyDCA10SPX4/DCA10SPXU4 Rules for Safe Operation Malfunction DCA10SPX4/DCA10SPXU4 Rules for Safe OperationBattery Safety Death Guidelines section in this manual Towing and Transporting SafetyPage DCA10SPX4/DCA10SPXU4 Installation Mounting DCA10SPX4/DCA10SPXU4 InstallationOutdoor Installation Indoor InstallationDCA10SPX4/DCA10SPXU4 General Information Major Components DCA10SPX4/DCA10SPXU4 Major ComponentsDCA10SPX4/DCA10SPXU4 Generator Control Panel Output Terminal Familiarization DCA-10SPX4 /U4- Output Terminal Panel FamiliarizationL5-30R Twist Lock 100 VAC Receptacle Option DCA-10SPX4 /U4 Output Terminal Panel FamiliarizationVAC Gfci Receptacle Connecting Loads Describes the generator’s current output capability Single Phase LoadDCA10SPX4/DCA10SPXU4 Load APPLICATION/MAXIMUM Amps Generator AmperageRefilling the Fuel System Circuit BreakersLubrication Oil Fuel CheckRefueling Refueling ProcedureEnce Figures 16 Vol % Freezing Point Air Cleaner Fan Belt TensionMm when depressed with the thumb as shown below Operation Freezing WeatherAlternator BatteryBattery Cable Installation WiringDirect exhaust away from nearby personnel DCA10SPX4/DCA10SPXU4 Generator START-UP ProcedureBefore Starting Engines exhaust contains harmful emissionsAmmeter No Load Set the Speed Control Switch to the RUN positionEmergency Shutdown Procedure Normal Shutdown ProcedureFuel Addition General Inspection Air CleanerAir Cleaner with Dust Indicator If Equipped Service DailyDCA10SPX4/DCA10SPXU4 Maintenance Check the wheel and drum for free rotation DCA10SPX4/DCA10SPXU4 Trailer MaintenanceBrake Adjustment BrakesSuspension Tires/Wheels/Lug NutsTire Wear/Inflation Wheel Lug Nuts Tightening Sequence Lug Nut Torque RequirementsGenerator Wiring Diagram DCA10SPX4/DCA10SPXU4 Generator Wiring DiagramEngine Wiring Diagram DCA10SPX4/DCA10SPXU4 Engine Wiring DiagramEngine Troubleshooting DCA10SPX4/DCA10SPXU4 Troubleshooting EngineDCA10SPX4/DCA10SPXU4 Troubleshooting Engine Generator Troubleshooting DCA10SPX4/DCA10SPXU4 Troubleshooting GeneratorFailure Diagnosis Lamp Code DCA10SPX4/U4 Troubleshooting PRE-HEAT Lamp CodesDCA10SPX4/DCA10SPXU4 Note DCA10SPX4/U4 Explanation of Code in Remarks Column Sample Parts ListDCA10SPX4/DCA10SPXU4 Suggested Spare Parts DCA10SPX4/DCA10SPXU4 Generator Assy 8001070003 83210001020601821374 0601822630DCA10SPX4/DCA10SPXU4 Control Panel Assy 0601800281 B0224005103M0224000003 0601800455 Frequency METER, 45~65 Hz 0601805745DCA10SPX4/DCA10SPXU4 Control Panel Assy M0214000003 06018066400601830771 B0214002903DCA10SPX4/DCA10SPXU4 Output Receptacle Assy 0601811033 06018151090601812598 0601811035DCA10SPX4/DCA10SPXU4 Engine and Radiator Assy B0304200403 B09242001741638297011 1641432433DCA10SPX4/DCA10SPXU4 Engine and Radiator Assy 0199900450 08020811048702082004 0016906015DCA10SPX4 Battery Assy 0037808000 0165308026B1345200114 0805002904DCA10SPXU4 Battery Assy M0344000003 Y0602220193M0484600004 Y0602220920DCA10SPX4/DCA10SPXU4 Muffler Assy 0207008000 B0331100703B0334000503 1526312371DCA10SPX4/DCA10SPXU4 Fuel Tank Assy B0364300403 B03640007030810105800 0810105900DCA10SPX4/DCA10SPXU4 Enclosure Assy M0414800004 B0414002202M0414000102 D3414800104DCA10SPX4/DCA10SPXU4 Enclosure Assy 25A M0494500604 B0464001002M0464000102 25A B0494500104DCA10SPX4/DCA10SPXU4 Rubber Seals Assy 0221700640 02292006500229400695 0221700900DCA10SPX4/DCA10SPXU4 Nameplate Assy 0800650804 08406141042635 B9504501204Effective October 1, 2002 Terms and Conditions of Sale Parts Page Heres HOW to GET Help

DCA10SPXU4, DCA10SPX4 specifications

The Multiquip DCA10SPX4 and DCA10SPXU4 are highly regarded portable diesel generators that cater to a wide range of applications, from construction sites to outdoor events. These models are part of Multiquip’s popular line of reliable power solutions, designed to deliver robust performance and versatility.

At the heart of both models lies a powerful and efficient Yanmar diesel engine. The DCA10SPX4 offers a rated output of 10 kVA, while the DCA10SPXU4 provides the same output, making both models suitable for powering tools, lights, and other equipment. The Yanmar engine is known for its efficiency, offering longer run times between refueling and lower operational costs, making these generators economical choices for users.

One of the standout features of the DCA10SPX4 and DCA10SPXU4 is their durability and rugged design. Constructed with a powder-coated steel frame, these generators can withstand harsh environments and heavy use. The enclosed design reduces noise levels, making them ideal for urban jobsites or residential areas where noise restrictions may apply. Additionally, the weather-resistant design enhances their usability in unfavorable weather conditions.

Both models come equipped with advanced monitoring features and controls that make operation straightforward. An easy-to-read digital display provides real-time information regarding output voltage, frequency, and engine performance. This allows operators to monitor their generator’s performance swiftly and efficiently, ensuring smooth operation throughout usage.

In terms of safety, the DCA10SPX4 and DCA10SPXU4 incorporate various protective mechanisms. They include an automatic shutdown feature that activates in the event of low oil pressure or overheating, protecting the engine from damage. Furthermore, the generators are equipped with overload protection to prevent equipment damage from excessive loads.

Another notable characteristic is the generator's portability. Both models feature a compact design, lightweight structure, and integrated lifting hooks, making them easy to transport and position on job sites. Their user-friendly design allows for quick setup and disassembly, ensuring minimal downtime for users.

Overall, the Multiquip DCA10SPX4 and DCA10SPXU4 generators combine efficiency, durability, and user convenience, making them an outstanding choice for professionals seeking dependable power solutions in various applications. Whether powering construction tools or supporting outdoor events, these generators deliver reliable performance tailored to meet diverse energy needs.