Multiquip DCA10SPXU4 Operation Freezing Weather, Vol % Freezing Point, Must be less than 50%

Page 27

DCA10SPX4/DCA10SPXU4 — SETUP

Coolant (Antifreeze/Summer Coolant/Water)

KUBOTA recommends antifreeze/summer coolant for use in their engines, which can be purchased in concentrate (and mixed with 50% demineralized water) or pre-diluted. See the KUBOTA Engine Owner's Manual for further details.

Cleaning the Radiator

The engine may overheat if the radiator fins become overloaded with dust or debris. Periodically clean the radiator fins with compressed air. Cleaning inside the machine is dangerous, so clean only with the engine turned off and the negative battery terminal disconnected.

WARNING - BURN HAZARDS

If adding coolant/antifreeze mix to the radiator, DO NOT remove the radiator cap until the unit has completely cooled. The possibility of hot! coolant exists which can cause severe burns.

Day-to-day addition of coolant is done from the recovery tank. When adding coolant to the radiator, DO NOT remove the radiator cap until the unit has completely cooled. See Table 9 for engine, radiator, and recovery tank coolant capacities. Make sure the coolant level in the recovery tank is always between the "H" and the "L" markings.

Table 9. Coolant Capacity

Engine and Radiator

1.85 Gal. (7.0 liters)

 

 

Reserve Tank

.264 Gal (1.0 liters)

 

 

Operation Freezing Weather

When operating in freezing weather, be certain the proper amount of antifreeze (Table 10) has been added.

Table 10. Anti-Freeze

Operating Temperatures

Vol %

Freezing Point

 

 

Anti-Freeze

 

 

°C

°F

 

 

 

 

50

-37

-34

 

 

 

Air Cleaner

Periodic cleaning/replacement is necessary. Inspect it in accordance with the KUBOTA Engine Owner's Manual.

Fan Belt Tension

A slack fan belt may contribute to overheating, or to insufficient charging of the battery. Inspect the fan belt for damage and wear and adjust it in accordance with the

KUBOTA Engine Owner's Manual.

The fan belt tension is proper if the fan belt bends 10 to 15

mm(Figure 18) when depressed with the thumb as shown below.

Figure 18. Fan Belt Tension

CAUTION - ROTATING PARTS

NEVER place hands near the belts or fan while the generator set is running.

NOTE

When the antifreeze is mixed with

water, the antifreeze mixing ratio

 

 

must be less than 50%.

DCA10SPX4/DCA10SPXU4 — OPERATION AND PARTS MANUAL — REV. #0 (08/05/09) — PAGE 27

Image 27
Contents Model DCA10SPX4 Model DCA10SPXU4 DCA10SPX4/DCA10SPXU4 Proposition 65 Warning Diesel engine exhaust and someDCA10SPX4/DCA10SPXU4 Note Component Drawings Ordering parts has never been easier DCA10SPX4/DCA10SPXU4 Parts Ordering ProceduresDCA10SPX4/DCA10SPXU4 Specifications Dimension ft. mm DCA10SPX4/DCA10SPXU4 Dimensions TOP, Side and FrontHazard Symbols DCA10SPX4/DCA10SPXU4 Safety Message Alert SymbolsDCA10SPX4/DCA10SPXU4 Safety Message Alert Symbols General Safety DCA10SPX4/DCA10SPXU4 Rules for Safe OperationOff Deadly carbon Monoxide gas Malfunction DCA10SPX4/DCA10SPXU4 Rules for Safe OperationBattery Safety Death Guidelines section in this manual Towing and Transporting SafetyPage DCA10SPX4/DCA10SPXU4 Installation Mounting DCA10SPX4/DCA10SPXU4 InstallationOutdoor Installation Indoor InstallationDCA10SPX4/DCA10SPXU4 General Information Major Components DCA10SPX4/DCA10SPXU4 Major ComponentsDCA10SPX4/DCA10SPXU4 Generator Control Panel Output Terminal Familiarization DCA-10SPX4 /U4- Output Terminal Panel FamiliarizationDCA-10SPX4 /U4 Output Terminal Panel Familiarization VAC Gfci ReceptacleL5-30R Twist Lock 100 VAC Receptacle Option Connecting Loads Describes the generator’s current output capability Single Phase LoadDCA10SPX4/DCA10SPXU4 Load APPLICATION/MAXIMUM Amps Generator AmperageRefilling the Fuel System Circuit BreakersLubrication Oil Fuel CheckRefueling Procedure Ence Figures 16Refueling Vol % Freezing Point Air Cleaner Fan Belt TensionMm when depressed with the thumb as shown below Operation Freezing WeatherAlternator BatteryBattery Cable Installation WiringDirect exhaust away from nearby personnel DCA10SPX4/DCA10SPXU4 Generator START-UP ProcedureBefore Starting Engines exhaust contains harmful emissionsAmmeter No Load Set the Speed Control Switch to the RUN positionEmergency Shutdown Procedure Normal Shutdown ProcedureFuel Addition General Inspection Air CleanerAir Cleaner with Dust Indicator If Equipped Service DailyDCA10SPX4/DCA10SPXU4 Maintenance Check the wheel and drum for free rotation DCA10SPX4/DCA10SPXU4 Trailer MaintenanceBrake Adjustment BrakesTires/Wheels/Lug Nuts Tire Wear/InflationSuspension Wheel Lug Nuts Tightening Sequence Lug Nut Torque RequirementsGenerator Wiring Diagram DCA10SPX4/DCA10SPXU4 Generator Wiring DiagramEngine Wiring Diagram DCA10SPX4/DCA10SPXU4 Engine Wiring DiagramEngine Troubleshooting DCA10SPX4/DCA10SPXU4 Troubleshooting EngineDCA10SPX4/DCA10SPXU4 Troubleshooting Engine Generator Troubleshooting DCA10SPX4/DCA10SPXU4 Troubleshooting GeneratorFailure Diagnosis Lamp Code DCA10SPX4/U4 Troubleshooting PRE-HEAT Lamp CodesDCA10SPX4/DCA10SPXU4 Note DCA10SPX4/U4 Explanation of Code in Remarks Column Sample Parts ListDCA10SPX4/DCA10SPXU4 Suggested Spare Parts DCA10SPX4/DCA10SPXU4 Generator Assy 8001070003 83210001020601821374 0601822630DCA10SPX4/DCA10SPXU4 Control Panel Assy 0601800281 B0224005103M0224000003 0601800455 Frequency METER, 45~65 Hz 0601805745DCA10SPX4/DCA10SPXU4 Control Panel Assy M0214000003 06018066400601830771 B0214002903DCA10SPX4/DCA10SPXU4 Output Receptacle Assy 0601811033 06018151090601812598 0601811035DCA10SPX4/DCA10SPXU4 Engine and Radiator Assy B0304200403 B09242001741638297011 1641432433DCA10SPX4/DCA10SPXU4 Engine and Radiator Assy 0199900450 08020811048702082004 0016906015DCA10SPX4 Battery Assy 0037808000 0165308026B1345200114 0805002904DCA10SPXU4 Battery Assy M0344000003 Y0602220193M0484600004 Y0602220920DCA10SPX4/DCA10SPXU4 Muffler Assy 0207008000 B0331100703B0334000503 1526312371DCA10SPX4/DCA10SPXU4 Fuel Tank Assy B0364300403 B03640007030810105800 0810105900DCA10SPX4/DCA10SPXU4 Enclosure Assy M0414800004 B0414002202M0414000102 D3414800104DCA10SPX4/DCA10SPXU4 Enclosure Assy 25A M0494500604 B0464001002M0464000102 25A B0494500104DCA10SPX4/DCA10SPXU4 Rubber Seals Assy 0221700640 02292006500229400695 0221700900DCA10SPX4/DCA10SPXU4 Nameplate Assy 0800650804 08406141042635 B9504501204Effective October 1, 2002 Terms and Conditions of Sale Parts Page Heres HOW to GET Help

DCA10SPXU4, DCA10SPX4 specifications

The Multiquip DCA10SPX4 and DCA10SPXU4 are highly regarded portable diesel generators that cater to a wide range of applications, from construction sites to outdoor events. These models are part of Multiquip’s popular line of reliable power solutions, designed to deliver robust performance and versatility.

At the heart of both models lies a powerful and efficient Yanmar diesel engine. The DCA10SPX4 offers a rated output of 10 kVA, while the DCA10SPXU4 provides the same output, making both models suitable for powering tools, lights, and other equipment. The Yanmar engine is known for its efficiency, offering longer run times between refueling and lower operational costs, making these generators economical choices for users.

One of the standout features of the DCA10SPX4 and DCA10SPXU4 is their durability and rugged design. Constructed with a powder-coated steel frame, these generators can withstand harsh environments and heavy use. The enclosed design reduces noise levels, making them ideal for urban jobsites or residential areas where noise restrictions may apply. Additionally, the weather-resistant design enhances their usability in unfavorable weather conditions.

Both models come equipped with advanced monitoring features and controls that make operation straightforward. An easy-to-read digital display provides real-time information regarding output voltage, frequency, and engine performance. This allows operators to monitor their generator’s performance swiftly and efficiently, ensuring smooth operation throughout usage.

In terms of safety, the DCA10SPX4 and DCA10SPXU4 incorporate various protective mechanisms. They include an automatic shutdown feature that activates in the event of low oil pressure or overheating, protecting the engine from damage. Furthermore, the generators are equipped with overload protection to prevent equipment damage from excessive loads.

Another notable characteristic is the generator's portability. Both models feature a compact design, lightweight structure, and integrated lifting hooks, making them easy to transport and position on job sites. Their user-friendly design allows for quick setup and disassembly, ensuring minimal downtime for users.

Overall, the Multiquip DCA10SPX4 and DCA10SPXU4 generators combine efficiency, durability, and user convenience, making them an outstanding choice for professionals seeking dependable power solutions in various applications. Whether powering construction tools or supporting outdoor events, these generators deliver reliable performance tailored to meet diverse energy needs.