Multiquip GA4.5RA manual Death, Emergencies

Page 10

GA-4.5R/GA-4.5RA — RULES FOR SAFE OPERATION

DANGER-ELECTROCUTION HAZARDS

During operation of this generation, there exists the possibility of electrocution, electrical shock or burn, which can cause severe bodily harm or even

DEATH!

To avoid these hazards:

NEVER use damaged or worn cables when connecting equipment to the generator. Make sure power connecting cables are securely connected to the generator’s output receptacles, incorrect connections may cause damage to the generator and electrical shock.

NEVER grab or touch a live power cord with wet hands, the possibility exist of electrical shock, electrocution, and even death!

NEVER insert any objects into the output receptacles during operation. This is extremely dangerous. ALWAYS turn-off

the generator and place all circuit breakers in the “OFF” position when contact with the output receptacles is required. There exist the possibility of electrocution, electrical shock or burn, which can cause severe bodily harm or even death!

Backfeed to a utility system can cause electrocution and or property damage. NEVER connect the generator to a building's electrical system without a transfer switch or other approved device. All installations should be performed by a licensed electrician in accordance with all applicable laws and electrical codes. Failure to do so could result in electrical shock or burn causing serious injury or even death!

Emergencies

ALWAYS know the location of the nearest fire extinguisher.

ALWAYS know the location of the nearest first aid kit.

In emergencies always know the location of the nearest phone or keep a phone on the job site. Also know the phone numbers of the nearest ambulance, doctor and fire department. This information will be invaluable in the case of an emergency.

PAGE 10 — GA-4.5R/GA-4.5RA A.C. GENERATOR— OPERATION & PARTS MANUAL — REV. #1 (11/27/06)

Image 10
Contents Model GA4.5R/GA4.5RA Page Page Table of Contents Best Deal! Order via Internet Dealers Only Parts Ordering ProceduresOrder via Fax Dealers Only GA-4.5R/GA-4.5RA Safety Message Alert Symbols Hazard SymbolsThis generator, other property GA-4.5R/GA-4.5RA Rules for Safe Operation Power Cord Safety GA-4.5R/GA-4.5RA Rules for Safe OperationDeath EmergenciesGA-4.5R/GA-4.5RA Specifications GA-4.5R/GA-4.5RA Dimensions DimensionsGA-4.5R/GA-4.5RA General Information General Inspection Prior to OperationGA-4.5R/GA-4.5RA Load Application Extension CablesGA-4.5R/GA-4.5RA Controls and Indicators Generator Controls and ComponentsWhen the full power switch is Fuel Gauge Read this gauge to determine when fuel is low GA-4.5R/GA-4.5RA Generator Refueling Generator RefuelingIndoor Installation GA-4.5R/GA-4.5RA InstallationGenerator Grounding GA-4.5R/GA-4.5RA Installation Connecting the GroundMain Circuit Breaker General Inspection Prior to Operation Ground Power ToolsExtension Cable Load In WattsEngine Oil Check GA-4.5R/GA-4.5RA PRE-INSPECTION EngineBefore Starting Fuel CheckGA-4.5R/GA-4.5RA Initial START-UP Engine Before Starting the EngineGA-4.5R/GA-4.5RA Initial START-UP ENGINE/OPERATION Noises that would associate with lose componentsMain Circuit Breaker on Stopping The Engine 120 VAC ReceptacleGA-4.5R/GA-4.5RA Preparation for Long -TERM Storage Generator StorageGA-4.5R/GA-4.5RA Maintenance Engine Engine Maintenance ScheduleEngine Air Cleaner Spark Plug GapPage MQ GA-4.5R -WIRING Diagram Generator/Engine Wiring Diagram GA-4.5R OnlyMQ GA-4.5RA -WIRING Diagram GA-4.5R/GA-4.5RA -TROUBLESHOOTING Engine GA-4.5R/GA-4.5RA -TROUBLESHOOTING Engine WhiteGA-4.5R/GA-4.5RA -TROUBLESHOOTING Generator Generator TroubleshootingPage Part NO. Column GA-4.5R/GA-4.5RA Explanation of Code in Remarks ColumnNO. Column QTY. ColumnGA-4.5R/GA-4.5RA Suggested Spare Parts To 3 UnitsGA-4.5R/GA-4.5RA Name Plate and Decals Part Name QTY Remarks GA-4.5R/GA-4.5RA Generator Assy Part Name QTY. Remarks MQ GA-4.5R Control BOX Assy Part Name MQ GA-4.5RA Control BOX Assy A3214000103 GA-4.5R/GA-4.5RA Pipe Frame Assy MQ GA-4.5R/GA-4.5RA Robin EX270D20220 Crankcase Assy Valve Guide Robin EX270D20110/EX270D20220 Crankshaft and Piston Assy Crankshaft CP Robin EX270D20110/EX270D20220 Governor Assy Governor Lever Robin EX270D20110/EX270D20220 Intake and Exhaust Assy Robin EX270D20110/EX270D20220 Intake and Exhaust Assy Robin EX270D20110/EX270D20220 Muffler Assy MUFFLER, CP Robin EX270D20110/EX270D20220 AIR Cleaner Assy Body CP Robin EX270D20110/EX270D20220 Recoil Starter Assy Blower Housing CP Robin EX270D20110/EX270D20220 Carburetor Assy Valve Throttle Robin EX270D20110/EX270D20220 Flywheel Assy Flywheel CP Payment Terms Page Heres HOW to GET Help

GA4.5RA, GA4.5R specifications

The Multiquip GA4.5R and GA4.5RA are advanced generators designed for professionals who require reliable power sources across various applications. Engineered with cutting-edge technologies, these models stand out in the competitive generator market.

One of the key features of the GA4.5R and GA4.5RA is their robust power output. Both models are capable of delivering 4.5 kW of continuous power, making them suitable for a range of applications from construction sites to outdoor events and emergency backup. This reliable output is coupled with a reputable eco-friendly engine that minimizes fuel consumption while providing consistent power.

The design of the GA4.5R and GA4.5RA generators emphasizes ease of use and portability. With a compact and lightweight structure, these generators can be easily transported, making them ideal for users on the go. A user-friendly control panel enhances operational convenience, allowing users to monitor performance metrics such as voltage and frequency effortlessly.

In terms of durability, Multiquip has ensured that both models are built with high-quality materials that can withstand demanding conditions. The sturdy frame offers protection against falls and impacts, while the weather-resistant housing protects internal components from external elements. This rugged design guarantees longevity, making these generators a solid investment for users.

The GA4.5RA model introduces advanced technology with its electric start feature, adding even more convenience for users. This eliminates the need for manual recoil starting, making the generator easy to operate, especially in low-light conditions or for those who may have difficulty with traditional starting methods.

Additional safety features are integrated into both models, including low oil shutdown and circuit breaker protection, ensuring that the generator operates securely and efficiently. This attention to safety appeals to professionals who rely on their equipment to perform at optimal functionality without compromising user safety.

To summarize, the Multiquip GA4.5R and GA4.5RA generators are designed with power, portability, and durability in mind. Their advanced features and technologies cater to a variety of applications, making them an invaluable tool for anyone in need of reliable power solutions. With Multiquip's reputation for quality and performance, these models are poised to meet the demanding expectations of users across different industries.