Multiquip GA4.5RA manual GA-4.5R/GA-4.5RA Rules for Safe Operation, Power Cord Safety

Page 9

GA-4.5R/GA-4.5RA — RULES FOR SAFE OPERATION

ALWAYS be sure the operator is familiar with proper safety precautions and operation techniques before using generator.

NEVER leave the generator unattended, turn off engine when unattended.

Unauthorized equipment modifications will void all warranties.

ALWAYS ensure generator is on level ground before use.

DO NOT place hands or fingers inside generator engine compartment when engine is running.

NEVER run engine without air cleaner. Severe engine damage may occur.

NEVER change or adjust the engine speed which has been set at the factory prior to shipping.

Power Cord Safety

NEVER let power cables or cords lay in water.

NEVER stand in water while AC power from the generator is being transfer to a load.

NEVER use a defective or frayed power cable. Check the cable for cuts in the insulation.

NEVER use a extension cord that is frayed or damaged where the insulation has been cut.

ALWAYS make certain that proper power or extension cord has been selected for the job See Table 3.

Grounding Safety

ALWAYS make sure that electrical circuits are properly grounded per the National Electrical Code (NEC) and local codes before operating generator. Severe injury or death! by electrocution can result from operating an ungrounded generator.

ALWAYS make sure generator is properly grounded to a suitable earth ground (GROUND ROD). See installation section in this manual.

NEVER use gas piping as an electrical ground.

Maintenance Safety

NEVER lubricate components or attempt service on a running machine.

HighTemperatures – Always stop engine and allow the engine to cool before adding fuel, oil or performing service and maintenance functions. Contact with hot! components can cause serious burns.

Keep the machinery in proper running condition.

Fix damage to the machine immediately and replace any broken parts immediately.

ALWAYS replace any worn or damaged warning decals.

ALWAYS store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children and un-authorized personnel.

The electrical voltage required to operate the generator can cause severe injury or even death through physical contact with live circuits. Turn all circuit breakers OFF before performing maintenance on the generator.

Dispose of hazardous waste properly.Examples of potentially hazardous waste are used motor oil, fuel and fuel filters.

DO NOT use food or plastic containers to dispose of hazardous waste.

DO NOT pour waste, oil or fuel directly onto the ground, down a drain or into any water source.

Removing the engine oil drain plug while the engine is hot will result in hot oil to gush out of the oil drain plug, therefore causing severescaldingtoanypersonsinthegeneral area of the generator.

GA-4.5R/GA-4.5RA A.C. GENERATOR — OPERATION & PARTS MANUAL — REV. #1 (11/27/06) — PAGE 9

Image 9
Contents Model GA4.5R/GA4.5RA Page Page Table of Contents Parts Ordering Procedures Best Deal! Order via Internet Dealers OnlyOrder via Fax Dealers Only Hazard Symbols GA-4.5R/GA-4.5RA Safety Message Alert SymbolsThis generator, other property GA-4.5R/GA-4.5RA Rules for Safe Operation GA-4.5R/GA-4.5RA Rules for Safe Operation Power Cord SafetyEmergencies DeathGA-4.5R/GA-4.5RA Specifications Dimensions GA-4.5R/GA-4.5RA DimensionsGeneral Inspection Prior to Operation GA-4.5R/GA-4.5RA General InformationExtension Cables GA-4.5R/GA-4.5RA Load ApplicationGenerator Controls and Components GA-4.5R/GA-4.5RA Controls and IndicatorsWhen the full power switch is Fuel Gauge Read this gauge to determine when fuel is low Generator Refueling GA-4.5R/GA-4.5RA Generator RefuelingGA-4.5R/GA-4.5RA Installation Indoor InstallationGenerator Grounding Connecting the Ground GA-4.5R/GA-4.5RA InstallationExtension Cable General Inspection Prior to Operation Ground Power ToolsMain Circuit Breaker Load In WattsBefore Starting GA-4.5R/GA-4.5RA PRE-INSPECTION EngineEngine Oil Check Fuel CheckBefore Starting the Engine GA-4.5R/GA-4.5RA Initial START-UP EngineNoises that would associate with lose components GA-4.5R/GA-4.5RA Initial START-UP ENGINE/OPERATION120 VAC Receptacle Main Circuit Breaker on Stopping The EngineGenerator Storage GA-4.5R/GA-4.5RA Preparation for Long -TERM StorageEngine Maintenance Schedule GA-4.5R/GA-4.5RA Maintenance EngineSpark Plug Gap Engine Air CleanerPage Generator/Engine Wiring Diagram GA-4.5R Only MQ GA-4.5R -WIRING DiagramMQ GA-4.5RA -WIRING Diagram GA-4.5R/GA-4.5RA -TROUBLESHOOTING Engine White GA-4.5R/GA-4.5RA -TROUBLESHOOTING EngineGenerator Troubleshooting GA-4.5R/GA-4.5RA -TROUBLESHOOTING GeneratorPage NO. Column GA-4.5R/GA-4.5RA Explanation of Code in Remarks ColumnPart NO. Column QTY. ColumnTo 3 Units GA-4.5R/GA-4.5RA Suggested Spare PartsGA-4.5R/GA-4.5RA Name Plate and Decals Part Name QTY Remarks GA-4.5R/GA-4.5RA Generator Assy Part Name QTY. Remarks MQ GA-4.5R Control BOX Assy Part Name MQ GA-4.5RA Control BOX Assy A3214000103 GA-4.5R/GA-4.5RA Pipe Frame Assy MQ GA-4.5R/GA-4.5RA Robin EX270D20220 Crankcase Assy Valve Guide Robin EX270D20110/EX270D20220 Crankshaft and Piston Assy Crankshaft CP Robin EX270D20110/EX270D20220 Governor Assy Governor Lever Robin EX270D20110/EX270D20220 Intake and Exhaust Assy Robin EX270D20110/EX270D20220 Intake and Exhaust Assy Robin EX270D20110/EX270D20220 Muffler Assy MUFFLER, CP Robin EX270D20110/EX270D20220 AIR Cleaner Assy Body CP Robin EX270D20110/EX270D20220 Recoil Starter Assy Blower Housing CP Robin EX270D20110/EX270D20220 Carburetor Assy Valve Throttle Robin EX270D20110/EX270D20220 Flywheel Assy Flywheel CP Payment Terms Page Heres HOW to GET Help

GA4.5RA, GA4.5R specifications

The Multiquip GA4.5R and GA4.5RA are advanced generators designed for professionals who require reliable power sources across various applications. Engineered with cutting-edge technologies, these models stand out in the competitive generator market.

One of the key features of the GA4.5R and GA4.5RA is their robust power output. Both models are capable of delivering 4.5 kW of continuous power, making them suitable for a range of applications from construction sites to outdoor events and emergency backup. This reliable output is coupled with a reputable eco-friendly engine that minimizes fuel consumption while providing consistent power.

The design of the GA4.5R and GA4.5RA generators emphasizes ease of use and portability. With a compact and lightweight structure, these generators can be easily transported, making them ideal for users on the go. A user-friendly control panel enhances operational convenience, allowing users to monitor performance metrics such as voltage and frequency effortlessly.

In terms of durability, Multiquip has ensured that both models are built with high-quality materials that can withstand demanding conditions. The sturdy frame offers protection against falls and impacts, while the weather-resistant housing protects internal components from external elements. This rugged design guarantees longevity, making these generators a solid investment for users.

The GA4.5RA model introduces advanced technology with its electric start feature, adding even more convenience for users. This eliminates the need for manual recoil starting, making the generator easy to operate, especially in low-light conditions or for those who may have difficulty with traditional starting methods.

Additional safety features are integrated into both models, including low oil shutdown and circuit breaker protection, ensuring that the generator operates securely and efficiently. This attention to safety appeals to professionals who rely on their equipment to perform at optimal functionality without compromising user safety.

To summarize, the Multiquip GA4.5R and GA4.5RA generators are designed with power, portability, and durability in mind. Their advanced features and technologies cater to a variety of applications, making them an invaluable tool for anyone in need of reliable power solutions. With Multiquip's reputation for quality and performance, these models are poised to meet the demanding expectations of users across different industries.