6.If the engine has started, slowly return the choke lever (Figure 11 ) to the “OPEN” position. If the engine has not started repeat steps 1 through 6.

7.Beforethegeneratorisplacedintooperation,runtheengine for 3-5 minutes. Check for abnormal smells, fuel leaks, and

noises that would associate with lose components.

Figure 16. AC Voltmeter (120VAC)

8.Place the idle control switch (Figure 14) in the "OFF" (down) position. This will allow the engine run at speed about 3600 RPM's

Figure 14. Idle Control Switch (3600 rpm's)

Placing the idle control switch in the down position allows the

NOTE engine to operate at a maximum speed of about 3600 RPM's. When the idle control switch is placed in the up position (ON), the generator

will run at idle speed (2200 RPM's) until a load is applied, at that time the engine speed will increase to 3600 RPM's as long as the load is being applied. When the load is not in use, the engine speed will drop back to the idle mode after about 3 seconds.

9.Place the full power switch (Figure 15) in the "120V" (Up) position.

Figure 15. Full Power Switch (Up)

10.Refer to the AC voltmeter (Figure 16) on the control box. The voltage indicated on the voltmeter should be 120 VAC with no load applied.

11.If desired, verify with a voltmeter (Figure17) that 120 VAC is present at the GFCI receptacle and all three twist-lock receptacles as shown below.

Figure 17. 120 VAC Receptacles

The 240V L14-20R receptacle

is not operational (no voltage)

NOTEwhen the full power switch is in the 120V position.This receptacle is active (voltage) only when the full power switch is in the 240V position.

12.Place the full power switch (Figure 18) in the "240/ 120V" (Down) position.

Figure 18. Full Power Switch (Down)

PAGE 24 — GA-4.5R/GA-4.5RA A.C. GENERATOR— OPERATION & PARTS MANUAL — REV. #1 (11/27/06)

Image 24
Contents Model GA4.5R/GA4.5RA Page Page Table of Contents Parts Ordering Procedures Best Deal! Order via Internet Dealers OnlyOrder via Fax Dealers Only GA-4.5R/GA-4.5RA Safety Message Alert Symbols Hazard SymbolsThis generator, other property GA-4.5R/GA-4.5RA Rules for Safe Operation Power Cord Safety GA-4.5R/GA-4.5RA Rules for Safe OperationDeath EmergenciesGA-4.5R/GA-4.5RA Specifications GA-4.5R/GA-4.5RA Dimensions DimensionsGA-4.5R/GA-4.5RA General Information General Inspection Prior to OperationGA-4.5R/GA-4.5RA Load Application Extension CablesGA-4.5R/GA-4.5RA Controls and Indicators Generator Controls and ComponentsWhen the full power switch is Fuel Gauge Read this gauge to determine when fuel is low GA-4.5R/GA-4.5RA Generator Refueling Generator RefuelingGA-4.5R/GA-4.5RA Installation Indoor InstallationGenerator Grounding GA-4.5R/GA-4.5RA Installation Connecting the GroundGeneral Inspection Prior to Operation Ground Power Tools Extension CableMain Circuit Breaker Load In WattsGA-4.5R/GA-4.5RA PRE-INSPECTION Engine Before StartingEngine Oil Check Fuel CheckGA-4.5R/GA-4.5RA Initial START-UP Engine Before Starting the EngineGA-4.5R/GA-4.5RA Initial START-UP ENGINE/OPERATION Noises that would associate with lose componentsMain Circuit Breaker on Stopping The Engine 120 VAC ReceptacleGA-4.5R/GA-4.5RA Preparation for Long -TERM Storage Generator StorageGA-4.5R/GA-4.5RA Maintenance Engine Engine Maintenance ScheduleEngine Air Cleaner Spark Plug GapPage MQ GA-4.5R -WIRING Diagram Generator/Engine Wiring Diagram GA-4.5R OnlyMQ GA-4.5RA -WIRING Diagram GA-4.5R/GA-4.5RA -TROUBLESHOOTING Engine GA-4.5R/GA-4.5RA -TROUBLESHOOTING Engine WhiteGA-4.5R/GA-4.5RA -TROUBLESHOOTING Generator Generator TroubleshootingPage GA-4.5R/GA-4.5RA Explanation of Code in Remarks Column NO. ColumnPart NO. Column QTY. ColumnGA-4.5R/GA-4.5RA Suggested Spare Parts To 3 UnitsGA-4.5R/GA-4.5RA Name Plate and Decals Part Name QTY Remarks GA-4.5R/GA-4.5RA Generator Assy Part Name QTY. Remarks MQ GA-4.5R Control BOX Assy Part Name MQ GA-4.5RA Control BOX Assy A3214000103 GA-4.5R/GA-4.5RA Pipe Frame Assy MQ GA-4.5R/GA-4.5RA Robin EX270D20220 Crankcase Assy Valve Guide Robin EX270D20110/EX270D20220 Crankshaft and Piston Assy Crankshaft CP Robin EX270D20110/EX270D20220 Governor Assy Governor Lever Robin EX270D20110/EX270D20220 Intake and Exhaust Assy Robin EX270D20110/EX270D20220 Intake and Exhaust Assy Robin EX270D20110/EX270D20220 Muffler Assy MUFFLER, CP Robin EX270D20110/EX270D20220 AIR Cleaner Assy Body CP Robin EX270D20110/EX270D20220 Recoil Starter Assy Blower Housing CP Robin EX270D20110/EX270D20220 Carburetor Assy Valve Throttle Robin EX270D20110/EX270D20220 Flywheel Assy Flywheel CP Payment Terms Page Heres HOW to GET Help

GA4.5RA, GA4.5R specifications

The Multiquip GA4.5R and GA4.5RA are advanced generators designed for professionals who require reliable power sources across various applications. Engineered with cutting-edge technologies, these models stand out in the competitive generator market.

One of the key features of the GA4.5R and GA4.5RA is their robust power output. Both models are capable of delivering 4.5 kW of continuous power, making them suitable for a range of applications from construction sites to outdoor events and emergency backup. This reliable output is coupled with a reputable eco-friendly engine that minimizes fuel consumption while providing consistent power.

The design of the GA4.5R and GA4.5RA generators emphasizes ease of use and portability. With a compact and lightweight structure, these generators can be easily transported, making them ideal for users on the go. A user-friendly control panel enhances operational convenience, allowing users to monitor performance metrics such as voltage and frequency effortlessly.

In terms of durability, Multiquip has ensured that both models are built with high-quality materials that can withstand demanding conditions. The sturdy frame offers protection against falls and impacts, while the weather-resistant housing protects internal components from external elements. This rugged design guarantees longevity, making these generators a solid investment for users.

The GA4.5RA model introduces advanced technology with its electric start feature, adding even more convenience for users. This eliminates the need for manual recoil starting, making the generator easy to operate, especially in low-light conditions or for those who may have difficulty with traditional starting methods.

Additional safety features are integrated into both models, including low oil shutdown and circuit breaker protection, ensuring that the generator operates securely and efficiently. This attention to safety appeals to professionals who rely on their equipment to perform at optimal functionality without compromising user safety.

To summarize, the Multiquip GA4.5R and GA4.5RA generators are designed with power, portability, and durability in mind. Their advanced features and technologies cater to a variety of applications, making them an invaluable tool for anyone in need of reliable power solutions. With Multiquip's reputation for quality and performance, these models are poised to meet the demanding expectations of users across different industries.