Multiquip ga-6h manual GA-6H/GA-6HA Controls and Indicators, Generators Components

Page 17

GA-6H/GA-6HA — CONTROLS AND INDICATORS

Figure 3A. Generators Components

1.

Lifting Bail Eye – Attach a rope or chain to this lifting eye

 

when lifting of the generators is required. Never stand

 

underneath the generators while it is being lifted. Place

 

lifting eye in down position when not in use.

2.

AC-VoltmeterThis voltmeter indicates (with a mark) the

 

rated 60 Hz (single-phase) output voltage. In addition the

 

voltmeter can also be used as a diagnostic tool. If the

 

voltmeter indicator (needle) is below the rated voltage,

 

engine problems may exist (low/high RPM's). To prevent

 

damage to the generators or power tools turn the generators

 

OFF and consult your authorized Multiquip service dealer.

3.

Idle Control Switch – The generators are provided with

 

an automatic idle control device for noise suppression and

 

reduced fuel consumption. The automatic idle control

 

automatically engages under a no-load condition. With the

 

automatic idle control switched “ON”, the engine revolutions

 

will automatically drop to about 2600 rpm (low-speed

 

operation) within 3 seconds after the load stops. When the

 

operation is resumed, the engine speed is automatically

 

increased to about 3600 rpm (high-speed operation) as

 

soon as the load is connected.

4.

Operation Switch – Place this rocker switch in the "ON"

 

position (up) for normal operation.To turn-off the generators,

 

place the operation switch in the "OFF" position (down).

5.GFCI Duplex Receptacle – NEMA 5-20R, GFCI receptacle will provide 120V, 20 amps. (GA-6HA has two.)

6.

120V Output Receptacle – NEMA L5-20Rtwist-lock

 

receptacle will provide 120V, 20 amps, 60 Hz.

7.

120V Output Receptacle – NEMA L5-30Rtwist-lock

 

receptacle will provide 120V, 30 amps, 60 Hz.

8.

120V/240V Output Receptacle – NEMA L14-30R twist-

 

lock receptacle will provide (120V, 50 amps, or 240V,

 

25 amps, 60 Hz.)

9.

Main Breaker – This 2-pole circuit breaker (120/240V, 21

 

amps) protects the generators from short circuiting or

 

overloading. When starting the generators always have

 

the circuit breaker placed in the "OFF" position.

10.

Ground – This ground connection point should be

 

connect to a good earth ground (ground rod)

GA-6H/GA-6HA A.C. GENERATORS — OPERATION & PARTS MANUAL — REV. #0 (06/02/05) — PAGE 17

Image 17
Contents Model GA-6H/GA-6HA Page Heres HOW to GET Help Table of Contents When ordering parts Please supply the following information Parts Ordering ProceduresRespiratory Hazards GA-6H/GA-6HA Safety Message Alert SymbolsBurn Hazards Rotating Parts Hazards Equipment DamageRead this manual GA-6H/GA-6HA Rules for Safe OperationPower Cord Safety Emergencies DeathOperation and Safety Decals Machine Safety DecalsEffects of Altitude and Heat GA-6H/GA-6HA Specifications GeneratorsGA-6H/GA-6HA Specifications Engine Specifications EngineDimensions GA-6H/GA-6HA DimensionsGA-6H/GA-6HA General Information Incandescent Loads Single Phase Load 60 HzSmall Motors Large MotorsGenerators Components GA-6H/GA-6HA Controls and IndicatorsWhen the full power switch is FuelTank Fuel tank capacity is 5 gallons 19 liters GA-6H/GA-6HA Controls and IndicatorsGenerators Refueling GA-6H/GA-6HA Generator RefuelingOutdoor Installation GA-6H/GA-6HA InstallationIndoor Installation MountingConnecting the Ground GA-6H/GA-6HA InstallationGA-6H/GA-6HA PRE-INSPECTION General Inspection Prior to Operation Ground Power ToolsExtension Cable Main Circuit BreakerBefore Starting GA-6H/GA-6HA PRE-INSPECTION EngineEngine Oil Check Fuel CheckBefore Starting the Engine GA-6H/GA-6HA Initial START-UP EngineGA-6H/GA-6HA Initial START-UP/GENERATOR Operation Stopping the Engine Connecting the LoadGenerators Storage GA-6H/GA-6HA Preparation for Longterm StoragePage Engine Maintenance Schedule GA-6H/GA-6HA Maintenance EngineMaintenance GA-6H/GA-6HA Maintenance EngineGA-6H Wiring Diagram GA-6H -WIRING Diagram GeneratorGA-6HA Wiring Diagram GA-6HA -WIRING Diagram GeneratorEngine Troubleshooting GA-6H/GA-6HA -TROUBLESHOOTING EngineWhite Generator Troubleshooting GA-6H/GA-6HA -TROUBLESHOOTING GeneratorPage GA-6H/GA-6HA Explanation of Code in Remarks Column How to read the marks and remarks used in this partsItems Found In the Remarks Column Items Found In the Items Number ColumnDescription GA-6H/GA-6HA Suggested Spare PartsName Plate Assy GA-6H/GA-6HA Nameplate and DecalsDecalwarning Decal MQ MultiquipDecal Operating Instructions Generator Assy GA-6H/GA-6HA Generator AssyBEARING, 6304 2RU Nycm RECTIFIER, D3SB80SET BOLT, Rotor SET WASHER, BearingControl BOX ASSY. GA-6H GA-6H Control BOX AssyIdle Control SWITCH, C1550WA Full Power SWITCH, ET-330D12Operation SWITCH, C1550WA Control BOXControl BOX Assy GA-6HA Control BOX AssyGA-6HA Control BOX Assy Muffler Assy GA-6H/GA-6HA Muffler AssyBolt HEX Head MufflerBracket HEX NUTPipe Frame Assy GA-6H/GA-6HA Pipe Frame AssyBase GA-6HARubber Suspension Fuel TankAIR Cleaner Assy Honda GX340K1EDE2 Engine AIR Cleaner AssySEPARATOR, AIR Cleaner ELEMENT, AIR CleanerHOUSING, AIR Cleaner STAY, AIR CleanerCamshaft Assy Honda GX340K1EDE2 Engine Camshaft AssyROD, Push SPRING, Weight ReturnARM, Valve Rocker LIFTER, ValveCarburetor Assy Honda GX340K1EDE2 Engine Carburetor AssyCLIP, Wire Harness GASKET, AIR CleanerGasket SET Valve SET, FloatControl Assy Honda GX340K1EDE2 Engine Control AssyARM, Governor SPRING, Control AdjustingROD, Governor SPRING, GovernorCrankcase Cover Assy Honda GX340K1EDE2 Engine Crankcase Cover AssyHOLDER, Governor Weight WEIGHT, GovernorPIN, Governor Weight GASKET, Case CoverCrankshaft Assy Honda GX340K1EDE2 Engine Crankshaft AssyCrankshaft E-TYPE WEIGHT, BalancerCylinder Barrel Assy Honda GX340K1EDE2 Engine Cylinder Barrel AssyWIRE, Ground Switch ASSY., OIL LevelSHAFT, Governor ARM BOLT, Drain PlugCylinder Head Assy Honda GX340K1EDE2 Engine Cylinder Head AssyGUIDE, EX. Valve OS Optional GUIDE, Valve OS OptionalCLIP, Valve Guide GASKET, Cylinder HeadFAN Cover Assy Honda GX340K1EDE2 Engine FAN Cover AssyGROMMET, Drain Hole COVER, FAN *NH1* BlackShroud Flywheel Assy Honda GX340K1EDE2 Engine Flywheel AssyNUT, Special 16MM FAN, CoolingFLYWHEEL, Lamp Ignition Coil Assy Honda GX340K1EDE2 Engine Ignition Coil AssyGROMMET, Wire CLAMP, WireWIRE, Stop Switch 470MM HOLDER, Stop Switch WirePiston Assy Honda GX340K1EDE2 Engine Piston AssyRing SET, Piston STD BOLT, Connecting RODPiston STD PIN, PistonHonda GX340K1EDE2 Engine Recoil Starter Assy RATCHET, Starter PULLEY, Recoil StarterSPRING, Friction SPRING, Starter ReturnSolenoid Assy Honda GX340K1EDE2 Engine Solenoid AssyLEVER, Throttle SPRING, Choke ReturnLabels Assy Honda GX340K1EDE2 Engine Labels AssyEmblem MARK, AIR CleanerMARK, Choke MARK, OIL CautionEffective October 1, 2002 Terms and Conditions of Sale Parts Page Your Local Dealer is
Related manuals
Manual 2 pages 55.13 Kb

ga-6h, GA-6HA specifications

The Multiquip GA-6HA is a versatile and robust generator designed to meet the power needs of a variety of applications, particularly in construction, events, and emergency backup situations. With its compact design and impressive performance capabilities, the GA-6HA is an ideal choice for professionals and contractors who require reliable electrical supply in remote locations or during power outages.

One of the standout features of the GA-6HA is its powerful 6,000-watt output, which provides sufficient power to run multiple tools and equipment simultaneously. This generator is equipped with a Honda GX390 engine, known for its durability and fuel efficiency. The engine operates quietly, making it suitable for use in noise-sensitive environments. Furthermore, the advanced design of the engine ensures minimal emissions, aligning with environmental regulations and promoting cleaner operation.

In terms of technology, the GA-6HA is fitted with a heavy-duty alternator that delivers stable power with a rated output of 120/240 volts. This feature allows users to connect various electrical devices without worry of voltage fluctuations that could damage sensitive equipment. The generator also incorporates a manual reset circuit breaker for added safety, preventing overload conditions.

Durability is a significant characteristic of the GA-6HA, as it is built with a rugged steel frame that can withstand the rigors of outdoor use. The generator's design includes an integrated lift hook for easy transport and positioning on job sites. Additionally, the anti-vibration mounts help to minimize noise and maintain stability during operation.

The GA-6HA features multiple outlets, including 120V 20A duplex receptacles and a 120/240V 30A locking receptacle, providing flexibility for connecting various tools and appliances. An easy-to-read fuel gauge and easy-access control panel contribute to user-friendliness and operational efficiency.

Overall, the Multiquip GA-6HA is designed to be a reliable power solution, effectively combining performance, durability, and portability. Whether for construction sites, outdoor recreational activities, or emergency power needs, this generator stands out for its impressive features and user-centric design.