Multiquip DCA-45SSIU3 60 Hz Rules for Safe Operation, General Safety, Drugs or alcohol

Page 10

DCA-45SSIU3 (60 Hz) — RULES FOR SAFE OPERATION

DANGER - READTHIS MANUAL!

Failure to follow instructions in this manual may lead to serious injury or even DEATH! This equipment is to be operated by trained and qualified personnel only! This equipment is for industrial use only.

The following safety guidelines should always be used when operating the DCA-45SSIU3(60 Hz) Whisperwatt

Generator

General Safety:

DO NOT operate or service this equipment before reading this entire manual.

The operator MUST BE familiar with proper safety precautions and operations techniques before using generator.

This equipment should not be operated by persons under 18 years of age.

NEVER operate this equipment without proper protective clothing, shatterproof glasses, steel-toed boots and other

protective devices required by the job.

NEVER operate this equipment when not feeling well due to fatigue, illness or taking medicine.

NEVER operate this equipment under the influence or

drugs or alcohol.

NEVER use accessories or attachments, which are not recommended by MQ Power for this equipment. Damage to the equipment and/or injury to user may result.

Manufacturer does not assume responsibility for any accident due to equipment modifications. Unauthorized equipment modification will void all warranties.

Whenever necessary, replace nameplate, operation and safety decals when they become difficult read.

ALWAYS check the machine for loosened threads or bolts before starting.

NEVER operate the generator in an explosive atmosphere or near combustible materials. An explosion or fire could result causing severe bodily harm or even death.

NEVER touch the hot exhaust manifold, muffler or cylinder. Allow these parts to cool before servicing engine or generator.

HighTemperatures – Allow the engine

to cool before performing service and maintenance functions. Contact with hot! components can cause serious burns.

The engine of this generator requires an adequate free flow of cooling air. NEVER operate the generator in any enclosed or narrow area where free flow of the air is restricted. If the air flow is

restricted it will cause serious damage to the generator or engine and may cause injury to people. The generator engine gives off DEADLY carbon monoxide gas.

DO NOT place hands or fingers inside generator engine compartment when engine is running.

NEVER run engine without air filter.Severe engine damage may occur.

DO NOT leave the generator running in the manual mode unattended.

Refer to the Isuzu Engine Owner's Manual for engine technical questions or information.

ALWAYS store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children.

PAGE 10 — DCA-45SSIU3 (60 HZ) — OPERATION AND PARTS MANUAL — REV. #0 (11/30/05)

Image 10
Contents Parts List NO. M1870300904 Model DCA-45SSIU3Page Heres HOW to GET Help Wilmington Ave Carson, CADCA-45SSIU3 60 Hz Table of Contents Isuzu BB4JG1T EngineDCA-45SSIU3 60 Hz Parts Ordering Procedures When ordering parts Please supply the following informationDCA-45SSIU3 60 Hz Specifications DCA-45SSIU3 60 Hz Dimensions TOP, Side and Front DimensionsDCA-45SSIU3 60 Hz Safety Message Alert Symbols Injury to yourself and othersDCA-45SSIU3 60 Hz Safety Message Alert Symbols This generator, other property, orDCA-45SSIU3 60 Hz Rules for Safe Operation General SafetyDrugs or alcohol DCA-45SSIU3 60 Hz Rules for Safe Operation Electrical SafetyGenerator Grounding Maintenance Safety Battery SafetyTowing &Transporting Safety EmergenciesDCA-45SSIU3 60 Hz Generator Decals Generator DecalsDCA-45SSIU3 60 Hz Generator Decals DCA-45SSIU3 60 Hz Installation Indoor Installation DCA-45SSIU3 60 Hz InstallationOutdoor Installation When connecting the generatorGenerator Control Panel DCA-45SSIU3 60 Hz General InformationEngine Operating Panel Output Terminal PanelDCA-45SSIU3 60 Hz Major Components Generator Major ComponentsDCA-45SSIU3 60 Hz Generator Control Panel Adjustment of the generator’s output voltageAmmeter phase-selector switch Hertz Hz. Normally 60 HzDCA-45SSIU3 60 Hz Engine Operating Panel DCA-45SSIU3 60 Hz Output Terminal Panel Familiarization Output Terminal FamiliarizationDCA-45SSIU3 60 Hz Output Terminal Panel Familiarization F.C.I. Receptacle 120VAC Gfci ReceptaclesConnecting Loads Blower FanDCA-45SSIU3 60 Hz Load Application Single Phase LoadThree Phase Load Motors and motor-drivenGenerator OutputVoltages Voltage Selector SwitchDCA-45SSIU3 60 Hz Generator Outputs Generator AmperageDCA-45SSIU3 60 Hz Gauge Reading How to Read the OutputTerminal GaugesReading Amperage Uvwo Terminal Output Voltages Three-Phase PositionDCA-45SSIU3 60 Hz Output Terminal Panel Connections 3Ø 240/139 Output Terminal Lug Voltages1Ø 240V/120V Output Terminal Lug Voltages DCA-45SSIU3 60 Hz Output Terminal Panel Connections3Ø 480/277 Output Terminal Lug Voltages Output Terminal LugsLubrication Oil DCA-45SSIU3 60 Hz PRE-SETUPCircuit Breakers Fuel CheckRefueling Procedure DCA-45SSIU3 60 Hz PRE-SETUPRefueling Operation FreezingWeather Cleaning the RadiatorAir Cleaner Fan Belt Tension Must be less than 50%When connecting battery do the following BatteryBattery Cable Installation WiringEngines exhaust contains harmful emissions DCA-45SSIU3 60 Hz Generator START-UP ProcedureBefore Starting Direct exhaust away from nearby personnelFrequency Meter Hz Turn the ignition switch key to the Stop position DCA-45SSIU3 60 Hz GEN. START-UP PROCEDURE/SHUTDOWNRemove all loads from the generator DCA-45SSIU3 60 Hz Maintenance Check Oil Level Cleaning the Fuel StrainerAir Removal Replacing Oil FilterDCA-45SSIU3 60 Hz Maintenance To ensure adequate startingDCA-45SSIU3 60 Hz -TRAILER Maintenance Trailer MaintenanceBrakes DCA-45SSIU3 60 Hz -TRAILER MaintenanceBrake Adjustment Check the wheel and drum for free rotationTire Wear/Inflation Tires/Wheels/Lug NutsSuspension Lug Nut Torque Requirements DCA-45SSIU3 60 Hz -TRAILER MaintenanceStart all wheel lug nuts by hand DCA-45SSIU3 60 Hz -TRAILER Wiring Diagram Trailer/Towing Vehicle Wiring DiagramDCA-45SSIU3 60 Hz Generatorwiring Diagram Generator Wiring DiagramDCA-45SSIU3 60 Hz Enginewiring Diagram DCA-45SSIU3 60 Hz -TROUBLESHOOTING Generator Generator TroubleshootingDCA-45SSIU3 60 Hz -TROUBLESHOOTING Engine Engine TroubleshootingDCA-45SSIU3 60 Hz -TROUBLESHOOTING Engine Sample Parts List DCA-45SSIU3 60 Hz Explanation of Code in Remarks ColumnPart number on this Suggested Spare Parts list DCA-45SSIU3 60 Hz Suggested Spare PartsDCA-45SSIU3 60 Hz Generator Assy 0010310035 B31101002028051070003 0042510000DCA-45SSIU3 60 Hz Control BOX Assy DCA-45SSIU3 60 Hz Control BOX Assy DCA-45SSIU3 60 Hz Engine & Radiator Assy 0605000048 M19232000548970497081 0030010000DCA-45SSIU3 60 Hz Engine & Radiator Assy 0605515106 01500000180199900700 M9300000003DCA-45SSIU3 60 Hz Outputterminal Assy Output Terminal AssyM9220100104 M1230700103M9220100204 0039310000DCA-45SSIU3 60 Hz Engine Operating Panel Assy 0602103092 89704441808944024980 2A# 0601810245DCA-45SSIU3 60 Hz Battery Assy M9310500014 0602220187627MFD M9103000304DCA-45SSIU3 60 Hz Muffler Assy M1333001903 M13301007030016910025 8943690210DCA-45SSIU3 60 Hz Fuel Tank Assy M1363200104 M13630016020605505070 M9310500104DCA-45SSIU3 60 Hz Enclosure Assy Enclosure AssyM1423001902 M1413002902M1413400004 M1493106703DCA-45SSIU3 60 Hz Enclosure Assy 32-1 0016908020 M9310000103M1483600204 M1453200602DCA-45SSIU3 60 Hz Rubber Seals Assy 0228900620 02289013700229200660 0228900940DCA-45SSIU3 60 Hz Nameplate and Decals Assy M1550002003 M1550000204M1550001304 M1550002103Terms and Conditions of Sale Parts Page Your Local Dealer is

DCA-45SSIU3 specifications

The Multiquip DCA-45SSIU3 is a robust and versatile diesel generator designed to provide reliable power for various applications, making it an essential piece of equipment for construction sites, events, and emergency backup. This generator is renowned for its efficiency, durability, and user-friendly design, catering to a wide range of power needs while ensuring optimal performance.

One of the standout features of the DCA-45SSIU3 is its powerful 45 kVA output. This generator is powered by a reliable and fuel-efficient Yanmar diesel engine, which not only delivers consistent power but also ensures lower emissions, making it an environmentally friendly choice for power generation. With its high fuel efficiency, operators can expect longer run times between refuels, reducing downtime and increasing productivity on the job site.

The DCA-45SSIU3 boasts a compact and mobile design, equipped with a durable steel frame and a weather-resistant enclosure. This ensures that the generator can withstand harsh outdoor conditions while providing easy access for maintenance and operation. Its built-in forklift channels and lifting eyes enhance its portability, allowing for simple relocation to different job sites.

This generator is equipped with advanced technologies that enhance its performance and safety. The intuitive control panel features easy-to-read gauges and indicators for monitoring performance. Users can quickly access essential functions, including start/stop controls and circuit breaker protections, which safeguard the generator from overloads. Additionally, its automatic voltage regulation delivers stable power, ensuring that sensitive electronic equipment runs smoothly without risk of damage.

The DCA-45SSIU3 also includes a fuel tank designed for extended operation, with a capacity that provides significant hours of runtime. This feature is complemented by an efficient cooling system that maintains optimal engine temperatures, ensuring reliability even during prolonged usage.

In summary, the Multiquip DCA-45SSIU3 is a powerful and dependable generator that meets the demands of diverse applications. Its robust design, combined with advanced features and efficiency, makes it an ideal choice for contractors, event planners, and anyone needing reliable backup power. With a reputation for performance and longevity, this generator stands out in the competitive market of portable power solutions.